Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32
KITOZER
KITOZER

Industrial-Grade 144CH Black Aluminum Alloy Chassis

Table of Contents

1. Cover / Document Information

– Document Title: Industrial-Grade 144CH Black Aluminum Alloy Chassis Technical Design Solution

– Prepared by: Guangzhou Lain Intelligent System Development Co., Ltd.

– Brand: KITOZER (Pioneer)

– Date: August 2026

– Version: V1.0

– Project Type: Technical design solution for Industrial-Grade 144CH Black Aluminum Alloy Chassis

2. Table of Contents Structure

1. Company Introduction

2. Project Overview

3. User Requirement Analysis

4. Overall Design Description

5. Detailed System Design and Product Technical Parameters

6. Project Quotation and Configuration List

7. Core Solution Advantages

8. Technical Q&A

9. Construction Schedule Plan

10. Construction Organization Plan

11. After-Sales Service System

12. Operation and Maintenance Training Plan

13. Typical Project Cases

14. SEO Optimization System and Website Backend Configuration

15. Contact Information

3. Company Introduction

3.1 Company Development Overview

Founded in 2002, Guangzhou Lain Intelligent System Development Co., Ltd. is a high-tech enterprise dedicated to the computer room construction and intelligent protection field for more than two decades, integrating R&D, production, sales, engineering implementation and after-sales service. The company focuses on innovative breakthroughs in electromagnetic shielding technology, modular computer room technology and computer room environmental monitoring technology, and has grown into a source manufacturer with core competitiveness in the domestic computer room construction field.

After more than twenty years of industry accumulation, the company has built a large-scale production and manufacturing base equipped with advanced CNC sheet metal processing equipment, automated spraying production lines and professional testing laboratories, with an annual production capacity of hundreds of sets of shielding computer rooms, integrated cabinets and micro-module products. The company’s service network covers all provinces and cities across the country, providing thousands of computer room construction and renovation services for customers in government, military, scientific research, finance and enterprise fields.

3.2 Core Business System

The company’s core business revolves around the full-lifecycle construction of computer rooms, forming four major product and service systems:

– Computer room EPC general contracting service: one-stop services from solution design, manufacturing, on-site construction to commissioning and acceptance, covering shielding computer rooms, IDC data rooms, modular computer rooms, container computer rooms and other types;

– Core equipment R&D and production: independently produces KITOZER brand series products, including shielding cabinets, shielding desks, consoles, integrated data cabinets, micro-module cold aisle cabinets, outdoor rainproof cabinets, etc., supporting non-standard customization;

– Computer room environmental monitoring system: provides full-element monitoring solutions for temperature and humidity, water leakage, access control, video, fire protection, UPS and power distribution, realizing intelligent and unattended O&M;

– Shielding and security protection products: shielding rooms, shielding doors and windows, anechoic chambers and related auxiliary materials, widely used in confidential, military and scientific research fields.

3.3 Brand and Qualification Honors

The core brand KITOZER (Pioneer) focuses on computer room equipment and shielding products, positioned as an “efficient, green, innovative and safe” solution provider. Products have passed multiple authoritative tests and comply with national and industry standards. The company holds multiple utility model patents and software copyrights, has been awarded high-tech enterprise qualification, and follows the ISO9001 quality management standard.

3.4 Core Competitive Advantages

1. Source production, controllable quality: own production base and professional processing equipment; core products independently produced with full-process quality control, providing more cost-effective solutions without intermediate links;

2. Customized design, matching needs: tailor-made solutions per site conditions, technical requirements, configuration and budget, with multiple design options provided free of charge;

3. Professional team, rich experience: a professional technical team of engineers and project managers with more than ten years of industry experience;

4. Quality after-sales, full guarantee: a 7×24 professional online service system with dedicated project follow-up from early coordination to later O&M.

4. Project Background and Objectives

4.1 Project Background

With Industry 4.0 and the rapid spread of edge computing, industrial sites, edge machine rooms, communication base stations and outdoor monitoring stations demand higher protection, structural strength, heat dissipation, environmental adaptation and lightweight design from equipment chassis. Traditional cold-rolled steel chassis suffer heavy weight, easy corrosion, poor EM shielding and low heat-dissipation efficiency. Aluminum alloy — light, corrosion-resistant, thermally conductive, EM-shielding and easily formed — has become the preferred material for high-end industrial equipment chassis. This project designs a high-reliability matte-black anodized aluminum chassis for 144CH-spec equipment.

4.2 Project Objectives

Design an industrial-grade 144CH aluminum chassis, 500x440x350mm, compatible with both rack and desktop deployment; graded materials (3mm high-strength front panel, 2mm anti-rust side panels) balancing weight, strength and deformation resistance; 48 round openings (8 rows x 6 columns) on the front panel for ventilation and interface expansion with 18 standardized silk-screen markings; industrial matte-black hard anodizing for wear/corrosion/weather resistance; removable top cover and anti-slip rubber feet for easy O&M; full ISO9001 quality control with vibration, shock, salt-spray and temperature reliability tests for 7×24 stable operation.

4.3 Applicable Scenarios

Data-center edge compute nodes, small machine rooms, building weak-current rooms; industrial automation PLC cabinets, data-acquisition terminals, motion controllers; communication base stations, optical splice boxes, edge transmission nodes; shielded machine rooms and confidential offices; outdoor environmental monitoring stations, weather stations, traffic checkpoints; hospital medical equipment, laboratory instruments; security monitoring, AI vision analysis and smart-park terminal hosts.

5. User Requirement Analysis

5.1 Functional Requirements

144CH-spec equipment installation with standard mounting holes, 19″ rack compatibility and custom modules, ample internal space with cable management and cooling channels; 48 front openings as air inlets with rear fans forming a front-to-back horizontal airflow; 18 silk-screen markings (brand, name, status, port numbers, keys, warnings) for fast identification; removable top cover enabling installation/wiring/debugging/maintenance without dismantling the unit; 4 anti-slip anti-vibration rubber feet for stable desktop placement.

5.2 Performance Requirements

Uniform load >=50kg, 10g shock resistance, no deformation/loosening in long service; neutral salt spray >=500h without rust for humid/salt-spray/corrosive environments; -20~+60 degC working, -40~+85 degC storage, 5-95% RH; EM shielding >=40dB (10kHz-1GHz) via natural aluminum shielding plus conductive sealing at joints.

6. Design Principles and Applicable Standards

6.1 Design Principles

Material and process excellence: full aluminum — weight reduced 60%+ vs steel with superior corrosion resistance, thermal conductivity and EM shielding; hard anodizing (HV300, integral film — no peeling) outperforming paint/powder coating; CNC laser cutting and NC bending for precision, small assembly gaps and interchangeability; all edges deburred and chamfered, 304 stainless fasteners. Structure and function: modular removable top cover; 19″ standard + full customization (openings, silk-screen, size, internal structure, protection rating); scientific airflow (front in / rear out); multi-dimensional protection (sealing, corrosion resistance, EM shielding, earthing) with upgradeable ratings. Quality and service: source factory with full production chain and QC; certified products; 7×24 support, quotation-confirmed warranty, lifetime maintenance; project-confirmed competitive pricing with stable delivery.

6.2 Applicable Standards

GB/T 2423.5 (shock), GB/T 2423.10 (vibration), GB/T 2423.1/2 (temperature), GB/T 2423.3 (humidity), GB/T 10125 (neutral salt spray), GB/T 12190 (shielding effectiveness), GB/T 4208 (IP), RoHS 2.0; ISO9001 quality system; 19″ EIA rack standard.

7. System Architecture and Working Principle

7.1 Overall Structure

Chassis body: integrated folded frame (5052-H32 2mm, incl. side panels, rear cover, base) + 6061-T6 3mm front panel with 48 x phi22mm openings + removable top cover (2mm with stiffening ribs and sealing strip, 6 x 304 hand screws); internal: 2 x 19″ 3U mounting rails (6063-T5 aluminum profile, adjustable holes) with 482x400x320mm internal mounting space; 4 x NBR anti-slip feet with brass inserts; full-perimeter conductive foam + EPDM seals; 304 stainless fastener set; matte-black hard anodizing on all exposed aluminum; 18 white epoxy silk-screen markings; front inner sponge dust filter (washable).

7.2 Working Principle

Equipment mounts on the 19″ rails; heat dissipates through the 48 front openings (air inlets) across the internal volume and exits via optional rear 8025 fans — a front-to-back horizontal airflow duct (>=200W dissipation with 2 fans); the aluminum body conducts heat and provides natural EM shielding reinforced by conductive sealing at joints (10kHz-1GHz >=40dB); the M6 brass earthing terminal on the base (<=0.1 ohm) ensures electrical safety and shield grounding; the top cover removes by hand for direct access to internal devices.

8. Detailed Technical Design

8.1 Overall Parameters

500+-0.2 x 440+-0.2 x 350+-0.2mm; internal mounting 482x400x320mm; net weight <=8kg; uniform load >=50kg; 10g/11ms half-sine shock no permanent deformation (GB/T 2423.5); 5-500Hz sweep, 0.15mm amplitude, 10g no loosening/noise (GB/T 2423.10); -20~+60 degC working, -40~+85 degC storage, 5-95% RH; neutral salt spray >=500h; AC220V/DC48V; earth resistance <=0.1 ohm; insulation >=100M ohm; shielding 10kHz-100kHz >=50dB, 100kHz-10MHz >=45dB, 10MHz-1GHz >=40dB, 1-3GHz >=35dB (GB/T 12190); IP30 standard, IP54/IP65 upgrade; MTBF >=100,000h; design life >=10 years.

8.2 Material Parameters

6061-T6 (front panel): tensile >=260MPa, yield >=240MPa, elongation >=8%, HBW >=90, E 69GPa, density 2.70g/cm3, thermal 167W/(m·K), expansion 23.6×10-6/degC, conductivity 43% IACS; Mg 0.8-1.2%, Si 0.4-0.8%, Cu 0.15-0.4%. 5052-H32 (body/sides): tensile >=230MPa, yield >=190MPa, elongation >=10%, HBW >=68, E 70GPa, density 2.68g/cm3, thermal 138W/(m·K), expansion 23.8×10-6/degC, excellent marine-atmosphere corrosion resistance; Mg 2.2-2.8%, Cr 0.15-0.35%.

8.3 Surface Treatment

Hard anodizing: film thickness 20-25um; surface hardness >=300HV; gloss (60 deg) 5-10GU; color difference dE <=1.5; adhesion 0 (no peeling); 500g rubber abrasion 500 cycles no base exposure; anhydrous ethanol 100 wipes unchanged; salt spray >=500h; breakdown voltage >=500V; thermal shock 150 degC/room 10 cycles no cracking/peeling; RoHS 2.0 compliant.

8.4 Opening and Silk-Screen Precision

Openings: diameter tolerance +-0.05mm; center distance +-0.1mm; position +-0.15mm; chamfer C0.5+-0.2; wall roughness Ra <=1.6um; burr <=0.02mm. Silk-screen: position +-0.2mm; line width +-0.05mm; ink thickness 10-20um; min line 0.15mm; min font 8pt.

8.5 Accessories

Feet: NBR, Shore 60+-5A, phi30x10mm, M4 brass insert 6mm deep, slip coefficient >=0.8 (dry glass), compression set <=10%, -30~+120 degC, oil immersion 72h volume change <=5%, life >=5 years. Fasteners: 304 (06Cr19Ni10), tensile >=520MPa, yield >=205MPa, elongation >=40%, salt spray >=720h, passivated. Optional fan: 80x80x25mm, DC12/24V, 3000RPM, >=35CFM, <=35dB(A), dual ball bearings, life >=50,000h, IP55.

8.6 Protection Upgrades

IP54 (dust level 5, splash-proof level 4) for dusty/splash-prone workshops; IP65 (dust-tight, low-pressure jet-proof) for outdoor/high-humidity sites — via optimized sealing, waterproof glands and sealing strips without changing external dimensions.

9. Recommended Configuration and Preliminary Budget

9.1 Configuration Summary

Body frame (5052 2mm, one-piece folded); 6061-T6 3mm front panel with 48 phi22 openings (chamfered/deburred); removable top cover with ribs, seal and 6 x 304 hand screws; 2 x 19″ 3U mounting rails; 4 x NBR feet with brass inserts; conductive foam + EPDM seal set; 304 stainless fastener set; full matte-black hard anodizing; 18 silk-screen markings (white epoxy ink, film made); sponge dust filter; pearl-cotton + 5-layer carton + wood-frame packing; delivery; 13% VAT special invoice.

9.2 Budget Notes

Standard-configuration reference pricing, valid 30 days; customization (size, openings, interfaces, protection upgrade, internal structure) re-quoted; price includes production, testing, packing and transport, excludes on-site installation/commissioning; delivery 7-10 working days standard, 15-20 custom; batch orders confirmed separately. Tax-inclusive in RMB (CNY) only — no foreign-currency conversion.

10. Technical Specifications

10.1 System Specification Summary

Item Specification
Dimensions 500+-0.2 x 440+-0.2 x 350+-0.2mm; internal 482x400x320mm; 3U rack height; <=8kg
Materials Front 6061-T6 3mm (>=260MPa); body 5052-H32 2mm (>=230MPa); rails 6063-T5
Openings 48 x phi22mm (8×6), tolerance +-0.05mm, burr <=0.02mm; 18 silk-screen markings
Surface Matte-black hard anodizing 20-25um, >=300HV, adhesion 0, salt spray >=500h, RoHS 2.0
Structure Removable top cover (6 hand screws); 19″ 3U rails; 4 NBR feet (M4 brass inserts); conductive foam + EPDM seals; 304 fasteners
Performance Load >=50kg; 10g shock; 5-500Hz vibration; -20~+60 degC; 5-95%RH; MTBF >=100,000h; life >=10 years
Shielding 10kHz-100kHz >=50dB; 100kHz-10MHz >=45dB; 10MHz-1GHz >=40dB; 1-3GHz >=35dB (GB/T 12190)
Protection IP30 standard; IP54/IP65 upgrade without size change
Electrical AC220V/DC48V; earth <=0.1 ohm (M6 brass terminal); insulation >=100M ohm
Cooling Front-in/rear-out duct; optional 8025 fans 35CFM <=35dB, 2 fans >=200W dissipation
Delivery 7-10 working days standard; 15-20 custom; 12-month warranty; lifetime maintenance

10.2 Standards Compliance

GB/T 2423.5/10/1/2/3, GB/T 10125, GB/T 12190, GB/T 4208, RoHS 2.0, ISO9001; 19″ EIA standard; per-unit factory test reports.

11. Key Advantages and Customer Value

11.1 Material and Process Advantage

Full aluminum — 60%+ lighter than steel with superior corrosion resistance, thermal conductivity and EM shielding; hard anodizing (HV300, integral film, no peeling) far outlasting paint; CNC precision with small gaps and good interchangeability; deburred/chamfered edges, durable silk-screen, 304 fasteners.

11.2 Structure and Function Advantage

Removable top cover for rapid O&M; 19″ standard + full customization; scientific front-to-back airflow for efficient cooling; multi-dimensional protection (sealing, corrosion, shielding, earthing) with upgradeable ratings.

11.3 Quality and Service Advantage

Source factory with full production chain and QC — every unit factory-tested; certified products; 7×24 support, quotation-confirmed warranty, lifetime maintenance, batch inspection service; project pricing with stable delivery.

12. Technical Q&A (50+ Items)

12.1 Basics

Q1: Material — vs steel chassis?

A: Full aluminum: front 6061-T6 3mm, body 5052 2mm. Vs steel: ~1/3 weight, no rust (humid/salt-spray suitable), better heat conduction, natural EM shielding, finer industrial appearance.

Q2: Standard size and customization?

A: 500x440x350mm (3U); full size customization plus wall-mount, pole-mount and embedded forms.

Q3: Protection rating — waterproof/dustproof?

A: IP30 standard (blocks >2.5mm objects); upgrades to IP54/IP65 via sealing optimization, waterproof glands and strips for outdoor use.

Q4: What equipment fits inside?

A: 19″ standard 3U rack devices with 400mm depth — switches, servers, control boards, communication devices; custom mounting holes/trays/baseplates for non-standard devices.

Q5: What is 144CH?

A: The 144CH designation refers to the 144-channel-class equipment specification this chassis is designed to carry — standard rack-form devices with the required mounting, airflow and interface layout.

Q6: Is it suitable for outdoor use?

A: Yes with IP54/IP65 upgrade and weather-resistant anodizing; optional pole-mount bracket and heat-dissipation fins.

12.2 Structure and Process

Q7: Surface finish — will it peel?

A: Matte-black hard anodizing (electrochemical oxide film metallurgically bonded to the base) — never peels; high hardness, wear/scratch resistant, far longer life than painting.

Q8: Front panel openings customizable?

A: Yes — count, position, diameter, shape (square/irregular) for displays, buttons, interfaces, indicators, aviation plugs per drawings.

Q9: Silk-screen customization?

A: Yes — content, position, color and font customizable; customer logos, names, port labels, warnings supported; proof confirmed before production.

Q10: Edge sharpness?

A: All edges R3-R5 deburred and chamfered; opening edges chamfered — no exposed sharp edges, safe for installation and maintenance.

Q11: Anodizing thickness and hardness?

A: 20-25um film, >=300HV, adhesion 0, abrasion 500 cycles no exposure.

Q12: Assembly precision?

A: Laser cutting + NC bending: opening tolerance +-0.05mm, position +-0.15mm, burr <=0.02mm.

12.3 Installation and Use

Q13: Rack or desktop?

A: Both — 19″ rack with mounting ears (bottom and side holes), or desktop via 4 anti-slip feet.

Q14: Top cover removal — special tools?

A: No — 6 x 304 hand screws, tool-free removal for internal access.

Q15: Earthing?

A: M6 brass terminal on the base, earth resistance <=0.1 ohm; connect ground lug and tighten — ensures electrical safety and shielding effect.

Q16: Fan installation and cooling?

A: Rear standard fan positions, optional 8025 fans; front-in/rear-out duct; 2 fans >=200W dissipation; more/larger fans for high-power devices.

Q17: Cable management?

A: Internal space with cable channels; strong/weak separation during wiring; ties and labels per standard.

Q18: Can it be stacked?

A: Desktop stacking possible with rubber feet providing separation; rack mounting recommended for multiple units.

Q19: Weight?

A: <=8kg net — easy handling; 60%+ lighter than equivalent steel chassis.

Q20: Internal mounting space?

A: 482x400x320mm with adjustable 19″ rails.

12.4 Customization and Delivery

Q21: Customization information needed?

A: External size; panel opening requirements (drawings or device interface sizes); silk-screen content/position; internal mounting structure; protection rating and surface finish. Flow: requirements -> design -> drawing confirmation -> sampling (optional) -> batch production -> acceptance.

Q22: Delivery time?

A: 7-10 working days standard; 15-20 custom; expedited from 7 days when capacity allows.

Q23: Sampling before batch order?

A: Yes — 1 sample for test; sample fee per complexity, deductible from batch payment.

Q24: MOQ?

A: No strict MOQ — single-unit customization to batch orders supported.

Q25: Packaging?

A: Pearl cotton + 5-layer carton + wood frame — anti-collision and anti-extrusion.

Q26: Do you provide installation service?

A: Yes — on-site installation, wiring and commissioning available; or self-installation with remote guidance.

12.5 After-Sales

Q27: Warranty?

A: 12 months from acceptance — free repair/replacement for product-quality faults; exclusions: human damage, abnormal use, unauthorized modification, force majeure (paid at cost).

Q28: After warranty?

A: Lifetime maintenance (parts + labor at cost, no markup); technical drawings retained for long-term matching parts.

Q29: Technical consultation response?

A: 7×24 phone/WeChat; general questions within 1h; complex solutions within 24h; on-site 24h urban / 48h provincial.

Q30: Spare parts supply?

A: Common parts within 48h, special parts within 72h.

Q31: Follow-up service?

A: Quarterly phone follow-up in warranty; annual free on-site inspection for batch customers; free upgrade solutions.

Q32: Warranty restart on replacement?

A: Replaced parts/units restart their own warranty period.

12.6 Performance and Environment

Q33: Load capacity?

A: Uniform load >=50kg; heavier duty via reinforced rails/structure customization.

Q34: Shock and vibration?

A: 10g/11ms half-sine shock; 5-500Hz sweep 0.15mm/10g — no deformation, loosening or abnormal noise.

Q35: Temperature range?

A: -20~+60 degC working; -40~+85 degC storage; 5-95%RH non-condensing.

Q36: Salt spray resistance?

A: >=500h neutral salt spray no rust; 5052 alloy with excellent marine-atmosphere resistance.

Q37: EM shielding effectiveness?

A: 10kHz-1GHz >=40dB (50/45/40/35dB per band) per GB/T 12190; B-class compatible in shielded-room applications.

Q38: Insulation and safety?

A: Insulation >=100M ohm; earth <=0.1 ohm; no sharp edges; 304 fasteners.

Q39: MTBF and life?

A: MTBF >=100,000h; design life >=10 years.

Q40: Cooling capacity?

A: Front 48 openings + rear fans; 2 x 8025 fans >=200W dissipation; airflow front-to-back horizontal.

12.7 Application-Specific

Q41: Suitable for data-center edge nodes?

A: Yes — lightweight, low-noise passive cooling option, rack-compatible, EM shielding.

Q42: Suitable for factory PLC cabinets?

A: Yes — IP54 upgrade, anodized surface resisting oil/corrosion, custom baseplates for control boards.

Q43: Suitable for outdoor base stations?

A: Yes — IP65 upgrade, heat-dissipation fins, weather-resistant anodizing, pole-mount bracket, waterproof glands.

Q44: Suitable for shielded rooms?

A: Yes — conductive foam at joints, shielded glands and mesh at openings — B-class shielding verified by third-party testing.

Q45: Medical/lab instruments?

A: Yes — clean appearance, corrosion resistance, stable mounting; custom openings for instrument interfaces.

Q46: Why aluminum over steel for this application?

A: 60% lighter, rust-free, better heat transfer, EM shielding, fine texture — lower logistics and installation cost, longer life in harsh environments.

Q47: Color options?

A: Matte black standard; other anodized colors available per requirement.

Q48: Does hard anodizing insulate?

A: Film breakdown voltage >=500V provides insulation while the base earthing terminal maintains electrical safety and shielding.

Q49: Large batch delivery stability?

A: Stable capacity with dedicated production lines; batch orders confirmed with delivery schedule; consistency guaranteed by ISO9001 process control.

Q50: Why choose KITOZER/Lain?

A: Full-aluminum hard-anodized industrial quality, 19″ + full customization, efficient airflow, multi-dimensional protection, source-factory pricing, quotation-confirmed warranty and lifetime service.

13. Construction Schedule

13.1 Schedule (Standard Custom Project, ~18-19 Days Total)

Stage No. Work Days Responsibility Acceptance node
Design confirmation 1 Requirement communication and preliminary design 2 Design engineer Preliminary scheme confirmed
2 Detailed drawing and review 1 Technical lead Production drawings finalized
Production 3 Raw material procurement and incoming inspection 2 Procurement + QC Materials qualified
4 CNC cutting and bending 3 Sheet-metal shop Semi-finished dimension check
5 Surface treatment and silk-screen 3 Surface shop Appearance and film check
6 Assembly and accessory fitting 2 Assembly shop Assembly precision check
Factory test 7 Full-performance factory test 1 QC Test report issued
8 Packing and shipping preparation 1 Warehouse Goods dispatched
Logistics 9 Delivery to site 2-3 Logistics Goods intact
On-site 10 Unpacking and count 0.5 Engineer + client Signed unpacking form
11 Chassis mounting and equipment racking 1 Field engineer Firm and neat
12 Wiring and power-on test 0.5 Field engineer Devices running
Acceptance 13 Overall acceptance and document handover 0.5 PM + client Signed acceptance report

Simple requirements or batch orders shorten the period; self-installation removes on-site stages; remote delivery adds logistics time.

14. Construction Organization and Quality/Safety Measures

14.1 Preparation

Technical: design/field engineers review drawings and requirements with disclosure; detailed construction plan and schedule with clear roles; technical documents, drawings, inspection forms and acceptance standards ready. Materials: chassis, accessories, auxiliaries and tools complete and correct; all materials factory-inspected with certificates; packaging per transport requirements. Personnel: project team — PM 1 (overall coordination, client interface), technical engineer 1 (design, disclosure, on-site guidance), field engineer 1 (installation/debugging/testing), QC 1 (factory and site acceptance).

14.2 On-Site Flow

Unpacking inspection: joint unpacking; model/spec/quantity/accessory verification against order; transport-damage check with on-the-spot record; technical documents/certificates/reports verification; signed unpacking form. Mounting: mark positions; rack mounting via ears on cabinet columns with level/plumb adjustment and uniform gaps; desktop placement on the designated surface with leveled feet; earthing connection with resistance test. Racking and wiring: fix internal devices on rails with even loading; cable connection with strong/weak separation, ties, clear labels, neat routing; check all interfaces secure and cables undamaged. Power-on test: continuity and insulation tests first (no short/earthing faults); power on and verify indicator status and normal startup; 2-hour continuous run checking temperature and status.

14.3 Quality Control

Construction per national standards and industry norms; self-check after each process before the next; key processes specially inspected by QC with records for traceability; all auxiliaries qualified — no unqualified materials; full quality acceptance after completion.

14.4 Safety

Compliance with site safety rules and PPE; live work by certified electricians only per electrical safety procedures — no violations; equipment and finished-product protection against scratches/impact; timely waste cleanup keeping the site tidy.

15. After-Sales Service

15.1 Warranty

12-month free warranty from acceptance — free repair, part or unit replacement for product-quality faults with no charge; exclusions: human damage, abnormal use, unauthorized modification, force majeure (fire/flood/lightning/earthquake) — paid at cost.

15.2 Response

7×24 phone/WeChat; general technical questions within 1h; fault reports: urban 4h response, 24h arrival; provincial 24h arrival; out-of-province 48h (remote areas negotiated); common parts within 48h, special parts within 72h.

15.3 Routine Service

Quarterly phone follow-up in warranty (usage, questions, maintenance advice); annual free on-site inspection for batch customers (status, cleaning, tightening, debugging, hidden issues); free upgrade solutions and technical support.

15.4 Post-Warranty

Lifetime maintenance — consultation, repair, parts, upgrades at parts + labor cost only; annual maintenance agreement option (regular inspection, priority response, spare units) for long-term stable operation.

16. Training Plan

16.1 Training Objectives and Audience

Training objectives: through systematic training, enable management personnel to fully understand the system structure, working principles and performance characteristics, master daily operation methods and inspection/maintenance essentials, identify common faults and handle simple problems, ensuring safe, stable and long-term operation.

Training audience: management and O&M personnel designated by the client, recommended 2-3 persons with basic electrical and equipment knowledge.

16.2 Tiered Training Content System

Level 1: Basic operation training (1 day)

– Basic principles: system concepts, structure composition, performance indicators;

– Daily operation standards: correct operation of equipment, control and safety systems;

– Daily inspection contents: daily/weekly/monthly check items;

– Safety precautions: usage prohibitions and emergency handling procedures.

Level 2: Maintenance training (1 day)

– Detailed structure of each subsystem and working principles;

– Daily maintenance methods: cleaning, fastening checks, routine care;

– Common fault identification and simple handling;

– Emergency handling procedures for power failure, fire and equipment faults.

Level 3: Advanced management training (as needed)

– Performance influencing factors and how to avoid degradation;

– Upgrade and expansion knowledge and specification requirements;

– Relevant national standards interpretation.

16.3 Training Methods and Schedule

– Methods: combination of “theory explanation + on-site practice + Q&A interaction”;

– Schedule: training arranged at the completion acceptance stage, synchronized with handover, 2 days of intensive training total; time flexibly adjustable; a free repeat training session is provided for newly assigned personnel.

16.4 Training Assessment and Documentation Delivery

– Assessment: theory written test plus practical operation; training qualification certificates issued upon passing; supplementary training for those who fail;

– Documentation delivery: complete O&M documentation, including operation and maintenance manual, equipment manuals and certificates, completion drawings and hidden work records, test reports and after-sales service contact card, all bound into volumes.

17. Anonymous Typical Project Scenarios

All project scenarios below are anonymous, generalized examples provided for reference only. No real customer names, addresses or identifiable details are disclosed.

17.1 Data Center Edge Node Chassis Project

Background. A large internet company deploying edge computing nodes needed lightweight, high-reliability chassis for edge servers and network switches in building weak-current rooms without dedicated cooling.

Solution. 144CH aluminum chassis with customized front-panel openings matching switch interfaces and status LEDs, dust filters and cooling fans added, internal custom cable-management brackets.

Results. Lightweight — easy on-site handling; aluminum heat conduction kept device temperatures stable even without AC; neat uniform appearance; 200+ units purchased and running stably with positive customer feedback.

17.2 Auto-Parts Factory Automation Control Chassis

Background. An auto-parts factory’s automated production line needed PLC control chassis in a workshop with dust and cutting-fluid splash — steel chassis rusted quickly.

Solution. IP54-upgraded aluminum chassis with dust/waterproof breather valves on the openings, hard-anodized surface resisting oil and corrosion, custom internal baseplates matching the customer’s PLC boards.

Results. Stable operation in the harsh workshop with no rust or dust ingress, solving the steel-chassis rust problem; service life greatly extended; subsequent production lines adopted the same chassis.

17.3 Telecom Operator Outdoor Base Station Chassis

Background. A telecom operator needed chassis for transmission equipment and power modules at outdoor base stations — requiring high/low-temperature tolerance, corrosion resistance, light weight and pole-mount installation.

Solution. Custom outdoor aluminum chassis upgraded to IP65 with heat-dissipation fins, weather-resistant anodizing, pole-mount bracket and waterproof glands for cable entry.

Results. Two years of open-air operation with no obvious aging or rust; internal equipment stable; protection and heat dissipation met requirements; passed the operator’s stringent environment tests.

17.4 Tertiary Hospital Shielded Machine Room Chassis

Background. A tertiary hospital building a classified shielded machine room needed equipment chassis with strong EM shielding compatible with the overall shielded room.

Solution. Shielding-upgraded chassis with high-conductivity foam at joints, metal shielding mesh at openings and shielded cable glands, ensuring overall shielding effectiveness.

Results. Passed third-party shielding tests meeting B-class standards; fully compatible with the shielded room; satisfied hospital requirements.

18. SEO Optimization Section

All reference prices in this technical solution are in RMB (CNY) only and are for reference purposes; final quotation is subject to the confirmed configuration.

18.1 Keyword System

– Core keywords: technical design solution, system configuration, technical parameters, construction and O&M services;

– High-conversion long-tail keywords: design solution, configuration list, technical parameters, construction plan, after-sales service;

– Industry traffic keywords: system architecture, applicable standards, technical Q&A, project cases;

– Brand keywords: KITOZER, Guangzhou Lain.

18.2 SEO Tag System

– Title tag: the article title — Guangzhou Lain KITOZER;

– Meta description: Guangzhou Lain professionally provides complete technical design solutions with detailed configuration list, full-system product technical parameters, construction organization plan and after-sales service — source manufacturer customization, compliant performance, third-party testing supported;

– H1 tag: the article title;

– H2 tags: system design and product parameters, construction organization plan, after-sales service and training, engineering cases.

18.3 Internal Link Anchor Text

– Core anchor text: technical design solution, system construction;

– Long-tail anchor text: configuration list, technical parameters, construction plan;

– Related anchor text: shielding cabinet, micro-module cold aisle, integrated computer room, outdoor cabinet.

19. Official Contact Information

– Company Name: Guangzhou Lain Intelligent System Development Co., Ltd.

– Brand: KITOZER (Pioneer)

– Official Website: https://gdlain.com

– Tel: +86 139 2228 9957 (WeChat available), +86 185 2066 8845 (WeChat available)

– Address: No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou, China

For any inquiries about this technical design solution, configuration customization, quotation or construction services, please contact us through the information above. We provide free design consultation and tailored solutions for your specific requirements.

Scroll to Top