KITOZER
KITOZER

Instrument Transformer Product Configuration

KITOZER Instrument Transformer Product Configuration Quotation List

2. Project Requirement Description

This project is a metering and protection supporting project for a power distribution system. The following products are required:

  • Current Transformers (CT) — for current signal acquisition and conversion
  • Voltage Transformers (VT) — for voltage signal acquisition and conversion
  • Zero-sequence Current Transformers (ZCT) — for leakage current monitoring

The products must meet the following requirements:

  • Applicable to 0.4kV low-voltage power distribution systems
  • Accuracy class meeting dual requirements of metering and protection
  • Indoor installation use
  • Satisfy electric energy metering, relay protection, and leakage monitoring needs

3. System Composition Introduction

This instrument transformer product series consists of three main categories:

  • Low-voltage Current Transformers — covering signal acquisition needs for metering circuits and protection circuits
  • Voltage Transformers — providing standard voltage signals for metering and voltage monitoring
  • Zero-sequence Current Transformers — for leakage monitoring and earth fault detection in residual current protection systems

The products are fully compatible with secondary equipment such as electricity meters, protection relays, and monitoring devices. Application standards and specifications referenced include:

  • GB/T 1208-2016 “Instrument Transformers — Current Transformers”
  • GB/T 1207-2017 “Instrument Transformers — Voltage Transformers”
  • GB 50054-2011 “Code for Design of Low Voltage Electrical Installations”
  • GB/T 20840.1-2010 “Instrument Transformers — Part 1: General Requirements”
  • JJG 313-2010 “Verification Regulation of Current Transformers for Measuring”
  • GB 55024-2022 “General Code for Building Electrical and Intelligent Systems”

4. Core Product Specifications & Parameters

4.1 Low-voltage Current Transformers

  • Rated Voltage: 0.66kV
  • Rated Current Ratio: 50/5A ~ 1000/5A (selectable)
  • Accuracy Class: 0.2S / 0.5 / 1 / 5P10 (selectable)
  • Rated Burden: 5VA ~ 15VA
  • Frequency: 50Hz
  • Installation Method: Bus-bar type / Through-core type, DIN-rail mounting or fixed mounting
  • Insulation Material: Epoxy resin cast, flame retardant class V0

4.2 Voltage Transformers

  • Rated Voltage: 380V/100V
  • Accuracy Class: 0.5
  • Rated Capacity: 15VA
  • Frequency: 50Hz
  • Insulation Class: Class B
  • Wiring Method: Single-phase, can be combined for three-phase use

4.3 Zero-sequence Current Transformers

  • Rated Voltage: 0.66kV
  • Inner Bore Diameter: Φ30mm ~ Φ150mm (selectable)
  • Rated Current Ratio: 1A/1mA, 5A/5mA, 100mA/5mA (selectable)
  • Accuracy Class: Class 1
  • Output Signal: Milliampere-level current signal
  • Installation Method: Cable-through type, installed around the cable

5. Core Functions & Features of Products

  • Current Signal Conversion: Proportionally converts large main-circuit currents into standard low currents (5A/1A) for metering instruments and protection devices
  • Voltage Signal Conversion: Converts system voltage into standard 100V voltage signals for metering and voltage monitoring
  • Zero-sequence Current Monitoring: Acquires zero-sequence current signals for leakage protection and earth fault monitoring
  • Electrical Isolation: Provides electrical isolation between primary high-voltage circuits and secondary low-voltage circuits, ensuring safety of secondary equipment and maintenance personnel
  • Metering & Protection Grading: Different accuracy classes are matched to metering and protection circuits respectively, meeting precision and dynamic/thermal stability requirements of various applications

6. Core Advantages of The Solution

  • High Accuracy, Low Error: Metering-class transformers control error within national standard limits, with excellent linearity and sustained high accuracy across a wide load range
  • Superior Insulation Performance: Epoxy resin integral casting process provides high insulation strength, moisture and dust resistance, and long service life
  • Flexible Installation Options: Through-core, bus-bar, and DIN-rail mounting structures accommodate different switchgear cabinets and wiring layouts
  • Strong Dynamic & Thermal Stability: Protection-class transformers withstand short-circuit current impacts and meet system short-circuit operating requirements
  • Compact Size, Light Weight: Optimized magnetic circuit design results in a compact footprint, saving installation space inside cabinets
  • Full Specification Coverage: Complete range of current ratios, accuracy classes, and mounting dimensions compatible with the majority of meters and protection devices on the market
  • Customization Services: Special current ratios, bore sizes, lead configurations, and accuracy classes can be customized for non-standard project scenarios
  • Stable & Reliable Quality: High-quality cold-rolled silicon steel cores, rigorous winding processes, and 100% factory testing ensure all parameters meet specifications
  • High Compatibility: Standard mounting dimensions compatible with mainstream brands; direct replacement of existing transformers without cabinet modification, reducing retrofit costs

7. Manufacturer Strength Introduction

KITOZER (Guangzhou Lai’an Intelligent System Development Co., Ltd.)

  • Founded in 2002, with over 20 years of industry experience
  • ISO 9001, ISO 14001, and ISO 45001 certified
  • Recognized as a high-tech enterprise
  • Equipped with professional instrument transformer production and testing lines
  • Complete type-test capabilities with full quality inspection before shipment
  • Project-confirmed manufacturing ensures competitive pricing and quality control
  • Capacity for customized production and OEM/ODM processing services
  • Strict enforcement of customer confidentiality agreements
  • Large stock of standard models for fast delivery
  • Professional technical selection guidance and after-sales support provided

8. Detailed Quotation Table

No. Product Name Model & Spec Technical Parameter Qty Unit Unit Price (USD) Total Price (USD) Brand Remark
1 Low-voltage Current Transformer KZR-CT/0.66-100/5 0.66kV, current ratio 100/5A, accuracy 0.5, rated burden 5VA, through-core type 9 pcs 19.98 179.82 KITOZER Branch circuit metering
2 Low-voltage Current Transformer KZR-CT/0.66-300/5 0.66kV, current ratio 300/5A, accuracy 0.5, rated burden 10VA, bus-bar type 4 pcs 37.74 150.95 KITOZER Main circuit metering
3 Low-voltage Current Transformer KZR-CT/0.66-600/5 0.66kV, current ratio 600/5A, accuracy 0.2S, rated burden 15VA, bus-bar type 3 pcs 79.92 239.76 KITOZER Main incoming metering
4 Low-voltage Voltage Transformer KZR-PT/0.4-380/100 Rated voltage 380V/100V, accuracy 0.5, rated capacity 15VA, single-phase 3 pcs 97.68 293.03 KITOZER Voltage acquisition
5 Zero-sequence Current Transformer KZR-ZCT-Φ75 Inner bore diameter Φ75mm, rated current 100mA/5mA, accuracy 1, cable-through type 2 pcs 71.04 142.08 KITOZER Leakage monitoring
6 Transformer Mounting Bracket KZR-CT-ZJ Compatible with 0.66kV bus-bar type transformers, galvanized steel plate 7 sets 6.66 46.61 KITOZER Fixing & installation accessory
— Total — — — — — 1052.25 — Excluding tax & freight

Total Quotation Price: USD 1052.25

9. Quotation Terms & Conditions

  • Currency: All prices are quoted in USD (United States Dollars)
  • Price Basis: EXW Guangzhou, China (or as negotiated)
  • Tax: The above quotation excludes tax and freight. A 10% surcharge applies for special value-added tax (VAT) invoices; a 3% surcharge applies for regular invoices
  • Shipping: Logistics delivery; freight is collect (freight to be paid by buyer upon delivery). Designated logistics carriers can be arranged upon request
  • Payment Terms: 30% deposit / 70% balance before shipment (negotiable)
  • Lead Time: 15-30 working days depending on configuration and order quantity
  • Validity Period: This quotation is valid for 30 days from the date of issue
  • Packing: Export-standard packing included; special packing requirements quoted separately

10. After-sales Service Description

  • Warranty: 12-24 months warranty depending on product model
  • Lifetime Technical Support: Free lifetime technical consultation and application support
  • Spare Parts: Long-term availability of spare parts and accessories
  • Troubleshooting: Remote troubleshooting support and on-site service options available
  • Quality Assurance: Project-confirmed quality inspection before shipment; any quality issues will be resolved promptly

11. Contact & Order Information

  • Manufacturer: Guangzhou Lai’an Intelligent System Development Co., Ltd. / Guangdong Lai’an Smart Equipment Co., Ltd.
  • Brand: KITOZER (proprietary brand)
  • Ordering: Orders can be placed via the official website gdlain.com or by contacting the KITOZER sales team directly
  • Contact Person: Mr. Zhou
  • Phone: 13538869979 (WeChat same number)
  • Address: Chaotian Industrial Park, Huashan Road No. 5, Shilou Town, Panyu District, Guangzhou, China
  • Response Time: All inquiries will receive a response within 24 hours

12. SEO Keywords & Tags

KITOZER quotation, instrument transformer price list, low-voltage current transformer quotation, current transformer factory price, voltage transformer quotation, zero-sequence transformer price, 0.66kV current transformer, metering current transformer, protection current transformer, KITOZER instrument transformer, wholesale instrument transformer quotation, current transformer model parameters, instrument transformer manufacturer price, self-produced current transformer supply

Shopping Cart