Toggle1. System Overview
The integrated computer room construction is designed in accordance with GB50174-2017 Code for Design of Data Centers and industry Class A computer room standards. Centered on the full range of KITOZER products, it integrates sub-systems including architectural decoration, power supply and distribution, cooling, cabinets, structured cabling, environmental monitoring, fire protection and security, to build an integrated infrastructure system featuring high reliability, high availability, energy efficiency and intelligent operation & maintenance.
Adopting modular and standardized design, the system offers three tiers (basic, medium and high-end) to flexibly adapt to different scales (small & medium enterprises, large institutions, data centers) and business requirements. It delivers one-stop full-cycle integrated services covering planning, design, supply, construction, commissioning and after-sales support, ensuring 7×24-hour stable operation of the computer room and supporting efficient operation of IT equipment as well as secure data storage and transmission.
2. System Composition
The integrated computer room construction system consists of eight core sub-systems that operate in deep synergy and are indispensable to one another:
- Architectural Decoration System: Includes anti-static floor treatment, fireproof and dustproof wall & ceiling finishing, sealed and insulated doors & windows, load-bearing reinforcement, etc., laying a solid physical foundation for the computer room.
- Power Supply & Distribution System: Comprises municipal power access, high/low voltage distribution cabinets, UPS uninterruptible power supply, battery packs, precision power distribution cabinets, PDU power sockets, and optional diesel generators, delivering stable uninterrupted power supply.
- Cooling & Heat Dissipation System: Covers precision air conditioners, row-level air conditioners, fresh air handling units, humidifiers, dehumidifiers, cold/hot aisle isolation, and optional liquid cooling for high-end scenarios, precisely controlling temperature at 22±2℃ and relative humidity between 40% and 60%.
- Cabinet & Supporting System: Includes standard server cabinets, network cabinets, cold aisle cabinets, cabinet accessories (trays, cable managers, blanking panels), cabinet PDUs, etc., providing standardized mounting carriers for IT equipment.
- Structured Cabling System: Contains optical fibers, twisted pairs, cable trays, trunking, patch panels, cable managers and grounding systems, constructing a high-speed, stable and easy-to-maintain data transmission network.
- Environmental Monitoring System: Integrates temperature & humidity sensors, water leakage detectors, smoke detectors, voltage/current sensors, UPS monitoring modules, air conditioner monitoring modules, monitoring hosts and cloud management platforms, enabling real-time monitoring and intelligent early warning all day long.
- Fire Protection System: Includes heptafluoropropane gas fire suppression devices, smoke/heat detectors, fire alarm control panels, emergency lighting, evacuation indicators and fire blocking, safeguarding fire safety of the computer room.
- Security System: Covers biometric access control (fingerprint/face/card swiping), high-definition video surveillance, infrared intrusion detectors and access control linkage alarms, strictly managing personnel access and implementing comprehensive security defense.
3. System Classification
3.1 Classification by Computer Room Grade
- Class A Computer Room (High-End Configuration): Fault-tolerant, applicable to financial institutions, securities firms, core government departments and large internet enterprises. It supports non-stop operation with fully redundant core equipment and full-system backup, with PUE ≤ 1.2.
- Class B Computer Room (Medium Configuration): Redundant, suitable for medium-sized enterprises, education, medical and scientific research institutions. Key equipment is configured with redundancy for fast failover upon faults, with PUE ≤ 1.4.
- Class C Computer Room (Basic Configuration): Entry-level, for small enterprises, branch offices and office computer rooms to meet basic operational demands. Equipment adopts single-circuit configuration, with PUE ≤ 1.6.
3.2 Classification by Functional Zones
- Main Computer Room Zone: Core area housing servers, storage, network equipment, cabinets and precision air conditioners, accounting for 60%–70% of the total computer room area.
- Auxiliary Zone: Includes UPS rooms, battery rooms, air conditioner rooms, cable entry rooms and spare parts storage rooms, providing supporting services for the main computer room.
- Monitoring & Management Zone: Houses environmental monitoring hosts, security surveillance displays and management terminals, realizing centralized monitoring and operation of the computer room.
- Administrative Zone: Consists of offices, duty rooms and changing rooms to satisfy daily office needs of operation & maintenance staff.
3.3 Classification by Deployment Mode
- Traditional Computer Room: Decentralized deployment with independent design and installation of each sub-system. Suitable for small & medium computer rooms with low cost but limited integration.
- Modular Micro Data Center: Integrated design embedding cabinets, UPS, air conditioners and monitoring into a single plug-and-play module. Cuts deployment cycle by 75%, ideal for medium & large computer rooms.
- Containerized Computer Room: Prefabricated integrated computer room fully manufactured and commissioned in the factory before transportation to site for rapid deployment. Applicable to field sites, temporary computer rooms and disaster recovery centers.
4. System Schematic Logic
(Note: The core logic of the schematic diagram is listed below; detailed drawings can be customized according to actual configurations)
- Power Circuit: Municipal power → High-voltage distribution cabinet → Transformer → Low-voltage distribution cabinet → UPS → Battery pack → Precision power distribution cabinet → Cabinet PDU → IT equipment. Standby generators start within 15 seconds upon municipal power failure to achieve seamless power switching.
- Cooling Circuit: Indoor air → Precision/row-level air conditioner → Cold aisle → Cabinet air intake → Heat dissipation of IT equipment → Hot aisle → Air conditioner air return → Circulating cooling. Fresh air handling units supplement outdoor air to maintain positive pressure inside the computer room.
- Monitoring Circuit: Temperature/humidity/water leakage/voltage/smoke sensors → Data collector → Environmental monitoring host → Local display terminal / Cloud platform. Abnormal data is uploaded in real time with multi-level alerts via SMS, WeChat and audible & visual alarms.
- Fire Protection Circuit: Smoke/heat detectors → Fire alarm control panel → Linked actions including access control unlocking, air conditioner shutdown and activation of heptafluoropropane suppression system for gas fire extinguishing.
- Security Circuit: Card swiping/face verification at access control → Access controller to unlock doors; 24-hour video recording, infrared intrusion triggers alarms and locks access control doors via linkage.
5. Full System Configuration List (KITOZER Brand, Basic / Medium / High-End Tiers)
5.1 Basic Configuration List (Class C Computer Room, 10–30㎡)
表格
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | All-Steel Anti-Static Floor | KT-DB-600 | 600×600×35mm, load ≥8kN/㎡, grounding resistance ≤1Ω, PVC veneer | 1 | Batch | KITOZER | Includes brackets and crossbeams |
| 2 | Fireproof Metal Wall Panel | KT-WB-1200 | 1200×2400×12mm, Class A fire rating, dustproof & moisture-proof, electrostatic spray coating | 1 | Batch | KITOZER | For wall cladding |
| 3 | Microporous Sound-Absorbing Ceiling | KT-DD-600 | 600×600×0.8mm aluminum alloy, sound absorption, fire retardant | 1 | Batch | KITOZER | For ceiling installation |
| 4 | Low-Voltage Distribution Cabinet | KT-PD-400 | 400V, rated current 250A, molded case circuit breaker, overload/short-circuit protection | 1 | Set | KITOZER | Municipal power distribution |
| 5 | UPS Uninterruptible Power Supply | KT-UPS-3KVA | 3KVA/2.4KW online type, 30min backup time, input voltage 160–275VAC | 1 | Unit | KITOZER | Single-circuit power supply |
| 6 | VRLA Lead-Acid Battery | KT-BAT-12V100AH | 12V 100AH sealed maintenance-free, float charging voltage 13.5–13.8V | 16 | Pcs | KITOZER | Matched with 3KVA UPS |
| 7 | Precision Air Conditioner | KT-AC-5KW | 5KW cooling capacity, constant temperature & humidity, temp 18–30℃, RH 40%–60%, air-cooled | 1 | Unit | KITOZER | Computer room cooling |
| 8 | Standard Server Cabinet | KT-CAB-42U | 42U, 600×800×2000mm cold-rolled steel, load ≥800kg, front & rear mesh doors | 2 | Units | KITOZER | IT equipment mounting |
| 9 | Cabinet PDU | KT-PDU-8 Port | 8×10A sockets, 220VAC input, overload protection, aluminum housing | 4 | Pcs | KITOZER | Cabinet power supply |
| 10 | Structured Cabling Tray | KT-QJ-200 | 200×100×1.2mm trough type, cold-rolled steel, fire retardant electrostatic coating | 1 | Batch | KITOZER | Cable routing |
| 11 | Cat5e UTP Cable | KT-CAT5E | 4-pair 8-core oxygen-free copper, 100Mbps transmission, flame-retardant PVC jacket | 1 | Box | KITOZER | Network cabling |
| 12 | Environmental Monitoring Host | KT-MON-100 | 10-inch touch screen, Modbus protocol, supports 10 sensor channels, local storage + cloud upload | 1 | Unit | KITOZER | Centralized monitoring |
| 13 | Temperature & Humidity Sensor | KT-TH-01 | Temp -40~80℃, accuracy ±0.5℃; RH 0–100%, accuracy ±3% RH | 2 | Pcs | KITOZER | Ambient monitoring |
| 14 | Water Leak Detector | KT-LD-01 | 5m sensing cable, detection precision ≤1mm, response time <3s | 1 | Set | KITOZER | Deployed under air conditioners |
| 15 | Heptafluoropropane Fire Suppression Unit | KT-FM-40L | 40L pipe-free, automatic activation, extinguishing concentration ≤8%, non-corrosive | 1 | Set | KITOZER | Main computer room fire protection |
| 16 | Card Swipe Access Control | KT-MJ-01 | ID card recognition, unlock response <1s, supports 1000 user cards, power-off unlock | 1 | Set | KITOZER | Computer room entrance |
| 17 | HD Network Camera | KT-CAM-1080P | 1080P, infrared night vision, IP66, remote mobile viewing | 2 | Units | KITOZER | Video surveillance |
5.2 Medium Configuration List (Class B Computer Room, 30–100㎡)
表格
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Frameless All-Steel Anti-Static Floor | KT-DB-600W | 600×600×40mm, load ≥12kN/㎡, grounding resistance ≤0.5Ω, HPL veneer | 1 | Batch | KITOZER | Adjustable brackets & crossbeams included |
| 2 | Thermal Insulated Fireproof Metal Wall Panel | KT-WB-1200B | 1200×2400×15mm Class A fire rating, thermal conductivity ≤0.03W/m·K, dust & moisture resistant | 1 | Batch | KITOZER | Walls & partitions |
| 3 | Aluminum Microporous Ceiling | KT-DD-600L | 600×600×1.0mm aluminum alloy, NRC ≥0.6, fire retardant | 1 | Batch | KITOZER | Ceiling system |
| 4 | High & Low Voltage Distribution Cabinet Set | KT-PD-630 | 10kV high voltage / 400V low voltage, rated 630A, dual municipal power input, intelligent metering | 1 | Set | KITOZER | Dual power supply access |
| 5 | UPS Uninterruptible Power Supply | KT-UPS-10KVA | 10KVA/8KW online double-conversion, 60min backup, 140–300VAC input, parallel hot standby | 2 | Units | KITOZER | Dual-machine redundant configuration |
| 6 | VRLA Lead-Acid Battery | KT-BAT-12V150AH | 12V 150AH sealed maintenance-free, float voltage 13.5–13.8V, ≥500 charge-discharge cycles | 32 | Pcs | KITOZER | Matched with 10KVA UPS |
| 7 | Precision Power Distribution Cabinet | KT-PDU-200 | 400V, rated 200A, branch voltage/current/power monitoring, surge protection | 1 | Unit | KITOZER | Cabinet power distribution |
| 8 | Row-Level Precision Air Conditioner | KT-AC-12KW | 12KW cooling capacity, constant T&RH, air-cooled, optimized for cold/hot aisle isolation | 2 | Units | KITOZER | Redundant deployment |
| 9 | Fresh Air Handling Unit | KT-XF-1000 | Air volume 1000m³/h, G4 filter, maintain room positive pressure ≥5Pa, noise ≤50dB | 1 | Unit | KITOZER | Fresh air supplementation |
| 10 | Cold Aisle Server Cabinet | KT-CAB-42UC | 42U, 600×1000×2000mm, load ≥1000kg, mesh doors, cold aisle sealing structure | 6 | Units | KITOZER | Centralized IT equipment deployment |
| 11 | Intelligent Cabinet PDU | KT-PDU-16S | 16×10A sockets, remote on/off, voltage/current monitoring, overload protection | 12 | Pcs | KITOZER | Intelligent power management |
| 12 | Enclosed Cable Tray | KT-QJ-300 | 300×150×1.5mm trough type, cold-rolled steel, fire retardant, separate strong/weak current routing | 1 | Batch | KITOZER | Isolated cable laying |
| 13 | Cat6 UTP Cable | KT-CAT6 | 4-pair 8-core oxygen-free copper, 10Gbps transmission, flame-retardant PVC jacket, anti-interference | 1 | Box | KITOZER | High-speed network cabling |
| 14 | Single-Mode Optical Fiber | KT-FIB-SM | 9/125μm core/cladding, transmission distance 10km, low attenuation flame-retardant jacket | 1 | Roll | KITOZER | Core backbone cabling |
| 15 | Integrated Environmental Monitoring System | KT-MON-500 | 15-inch touch screen, Modbus/SNMP, supports 50 sensor channels, cloud platform & mobile APP remote management | 1 | Set | KITOZER | Full-system monitoring |
| 16 | High-Precision T&H Sensor | KT-TH-02 | Temp -40~80℃, accuracy ±0.3℃; RH 0–100%, accuracy ±2% RH | 6 | Pcs | KITOZER | Multi-point monitoring for cabinets & room |
| 17 | Positioning Water Leak Detection System | KT-LD-02 | 20m sensing cable, positioning accuracy ≤0.5m, response time <2s, zone-based alerting | 2 | Sets | KITOZER | Full coverage for AC & water pipes |
| 18 | Smoke Detector | KT-YG-01 | Photoelectric type, response <10s, linkage alarm, adjustable sensitivity | 4 | Pcs | KITOZER | Computer room & battery room deployment |
| 19 | Pipe Network Heptafluoropropane Fire Suppression System | KT-FM-120L | 120L pipe network type, auto/manual activation, linkage with AC & access control | 2 | Sets | KITOZER | Fire protection for main room & battery room |
| 20 | Face & Card Swipe Access Control | KT-MJ-02 | Dual face/ID card recognition, unlock <0.5s, supports 5000 user cards/faces, remote authorization | 2 | Sets | KITOZER | Main room & monitoring room entrances |
| 21 | 4K HD Network Camera | KT-CAM-4K | 4K resolution, infrared night vision, AI motion detection, remote mobile viewing | 6 | Units | KITOZER | Full-area video surveillance |
| 22 | Infrared Intrusion Detector | KT-HW-01 | Detection distance 10m, 120° angle, anti-interference, linkage alarm | 4 | Pcs | KITOZER | Perimeter security protection |
5.3 High-End Configuration List (Class A Computer Room, ≥100㎡)
表格
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | High-Load Anti-Static Floor | KT-DB-600H | 600×600×50mm, load ≥16kN/㎡, grounding resistance ≤0.3Ω, anti-seismic reinforcement, HPL veneer | 1 | Batch | KITOZER | High-strength brackets & crossbeams |
| 2 | Premium Thermal Insulated Fireproof Wall Panel | KT-WB-1200H | 1200×2400×20mm Class A fire rating, thermal conductivity ≤0.02W/m·K, dust/moisture/bacteria resistant coating | 1 | Batch | KITOZER | Integrated wall, partition & ceiling |
| 3 | Modular Ceiling System | KT-DD-600H | 600×600×1.2mm aluminum alloy, NRC ≥0.8, fire retardant, detachable for maintenance | 1 | Batch | KITOZER | Ceiling installation |
| 4 | Intelligent High & Low Voltage Power Distribution System | KT-PD-1250 | 10kV / 400V, rated 1250A, dual independent municipal power input, remote scheduling, surge protection | 1 | Set | KITOZER | Dual mains + generator redundant power supply |
| 5 | Modular UPS Uninterruptible Power Supply | KT-UPS-40KVA | 40KVA/32KW online modular, N+1 redundancy, 120min backup, 120–380VAC input, parallel expansion | 4 | Units | KITOZER | Dual bus power supply architecture |
| 6 | Colloid Lead-Acid Battery | KT-BAT-12V200AH | 12V 200AH sealed colloid maintenance-free, float voltage 13.5–13.8V, ≥1000 charge cycles, low-temperature adaptation | 64 | Pcs | KITOZER | Matched with 40KVA UPS |
| 7 | Intelligent Precision Power Distribution Cabinet | KT-PDU-400 | 400V, rated 400A, branch voltage/current/power/harmonic monitoring, remote control, intelligent load balancing | 2 | Units | KITOZER | Dual-circuit power distribution |
| 8 | Variable-Frequency Row-Level Precision Air Conditioner | KT-AC-25KW | 25KW cooling capacity, constant T&RH, air/water cooling optional, variable frequency energy saving, cold/hot aisle isolation | 4 | Units | KITOZER | 2N redundant deployment |
| 9 | Total Heat Recovery Fresh Air Handling Unit | KT-XF-3000 | Air volume 3000m³/h, H13 filter, heat recovery efficiency ≥75%, room positive pressure ≥10Pa, low noise | 2 | Units | KITOZER | Redundant fresh air supply |
| 10 | Fully Sealed Cold Aisle Cabinet | KT-CAB-42UH | 42U, 600×1200×2200mm high-strength cold-rolled steel, load ≥1500kg, full cold aisle sealing with blanking panels | 20 | Units | KITOZER | High-density IT equipment deployment |
| 11 | Remote Intelligent PDU | KT-PDU-24S | 24×16A sockets, remote power on/off/restart, voltage/current/power monitoring, energy consumption statistics, overvoltage/overload protection | 40 | Pcs | KITOZER | Refined power consumption management |
| 12 | Shielded Structured Cabling Tray | KT-QJ-400 | 400×200×2.0mm trough type, cold-rolled steel with shielding ground layer, fire retardant, strict separation of strong & weak current | 1 | Batch | KITOZER | Full-site cable routing |
| 13 | Cat6A Augmented UTP Cable | KT-CAT6A | 4-pair 8-core oxygen-free copper, 40Gbps transmission, flame-retardant PVC jacket, anti-electromagnetic interference | 1 | Box | KITOZER | Ultra-high-speed network cabling |
| 14 | Ultra-Low Loss Single-Mode Optical Fiber | KT-FIB-SMH | 9/125μm core/cladding, transmission distance 40km, ultra-low attenuation flame-retardant jacket | 1 | Roll | KITOZER | Backbone network transmission |
| 15 | Digital Twin Environmental Monitoring System | KT-MON-1000 | 21-inch touch screen, Modbus/SNMP/HTTP protocols, supports 100 sensor channels, digital twin visualization & AI fault early warning | 1 | Set | KITOZER | Full-site intelligent monitoring |
| 16 | Ultra-High Precision T&H Sensor | KT-TH-03 | Temp -50~100℃, accuracy ±0.1℃; RH 0–100%, accuracy ±1% RH, explosion-proof design | 12 | Pcs | KITOZER | Multi-point monitoring for cabinets, room & battery room |
| 17 | High-Precision Positioning Water Leak Detection System | KT-LD-03 | 50m sensing cable, positioning accuracy ≤0.1m, response time <1s, zone positioning + video linkage alert | 4 | Sets | KITOZER | Full-area leak monitoring without blind spots |
| 18 | Smoke & Heat Composite Detector | KT-YW-01 | Combined photoelectric & heat sensing, response <5s, adjustable sensitivity, explosion-proof design | 8 | Pcs | KITOZER | Computer room, battery room & power distribution room deployment |
| 19 | Large Pipe Network Heptafluoropropane Fire Suppression System | KT-FM-200L | 200L pipe network type, auto/manual/emergency activation, extinguishing concentration ≤8%, full-system linkage + gas pressure relief | 4 | Sets | KITOZER | Zoned fire protection |
| 20 | Multi-Biometric Access Control | KT-MJ-03 | 4-way recognition (face/fingerprint/iris/card), unlock <0.3s, supports 10,000 user credentials, remote authorization & access log tracking | 4 | Sets | KITOZER | Entrances of core functional zones |
| 21 | 8K AI Intelligent HD Camera | KT-CAM-8K | 8K resolution, infrared night vision, IP66, AI intelligent analysis (face/behavior/anomaly detection), encrypted storage, remote mobile viewing | 12 | Units | KITOZER | Full-area intelligent surveillance without blind spots |
| 22 | Infrared & Microwave Dual-Technology Detector | KT-HW-02 | Detection distance 15m, 150° angle, anti-interference, AI false alarm filtering, linkage alert output | 8 | Pcs | KITOZER | Perimeter & core zone security defense |
| 23 | Diesel Generator Set | KT-FD-200KW | 200KW three-phase, auto-start within 10s after power failure, auto switching, 8-hour fuel endurance, remote monitoring | 1 | Unit | KITOZER | Emergency backup power supply |
| 24 | Liquid Cooling Heat Dissipation System | KT-LC-50KW | 50KW cooling capacity cold plate liquid cooling, heat dissipation efficiency improved by 300%, PUE ≤1.1, optimized for high-density computing power | 2 | Sets | KITOZER | Dedicated for high-end computing cabinets |
6. Full Product Technical Specifications
6.1 Architectural Decoration Products
- All-Steel Anti-Static Floor (KT-DB-600/600W/600H): 600×600mm size, thickness 35–50mm, cold-rolled steel material, load capacity 8–16kN/㎡, grounding resistance ≤0.3–1Ω, PVC/HPL veneer, Class A fire rating, surface resistance 10⁶–10⁹Ω.
- Fireproof Metal Wall Panel (KT-WB-1200/1200B/1200H): 1200×2400mm size, thickness 12–20mm, cold-rolled steel, Class A fire rating, thermal conductivity ≤0.02–0.03W/m·K, electrostatic spray / antibacterial coating, dust & moisture resistant, sound insulation ≥30dB.
- Microporous Sound-Absorbing Ceiling (KT-DD-600/600L/600H): 600×600mm size, thickness 0.8–1.2mm aluminum alloy, noise reduction coefficient ≥0.6–0.8, Class A fire rating, load capacity ≥5kg/㎡, detachable for maintenance.
6.2 Power Supply & Distribution Products
- UPS Uninterruptible Power Supply (KT-UPS-3KVA/10KVA/40KVA): Online double-conversion / modular type, power rating 3KVA–40KVA, power factor 0.8, input voltage 120–380VAC, input frequency 50±5Hz, output voltage 220VAC±1%, output frequency 50±0.1Hz, backup time 30–120min, overload capacity 125% for 10min, N+1 redundancy & parallel expansion support.
- Storage Battery (KT-BAT-12V100AH/150AH/200AH): Sealed VRLA lead-acid / colloid type, 12V rated voltage, capacity 100–200AH, float charging voltage 13.5–13.8V, equalizing charging voltage 14.4–14.8V, ≥500–1000 charge-discharge cycles, operating temperature -20~45℃, maintenance-free & low-temperature adaptive.
- Precision Power Distribution Cabinet (KT-PDU-200/400): Rated voltage 400V, rated current 200–400A, 50Hz frequency, 12–24 branch circuits, monitors voltage/current/power/harmonics with ±0.5% precision, Modbus/TCP communication, remote control & intelligent load balancing.
6.3 Cooling & Heat Dissipation Products
- Precision Air Conditioner (KT-AC-5KW/12KW/25KW): Cooling capacity 5–25KW, air/water/row-level cooling options, temperature control range 18–30℃ with ±0.5℃ precision, RH control 40%–60% with ±3% RH precision, adjustable fan speed, variable frequency energy saving, cold/hot aisle adaptive linkage with environmental monitoring.
- Fresh Air Handling Unit (KT-XF-1000/3000): Air volume 1000–3000m³/h, filter grade G4–H13, total heat recovery efficiency ≥75%, room positive pressure ≥5–10Pa, fan power 0.5–2KW, noise ≤50dB, energy-saving redundant backup design.
- Liquid Cooling System (KT-LC-50KW): 50KW cooling capacity cold plate liquid cooling, heat dissipation efficiency increased by 300%, operating temperature 20–30℃, working pressure 0.8–1.2MPa, PUE ≤1.1, optimized for high-density computing clusters with low energy consumption.
6.4 Cabinet & Supporting Products
- Server Cabinet (KT-CAB-42U/42UC/42UH): 42U height (2000–2200mm), 600mm width, depth 800–1200mm, cold-rolled steel, load capacity 800–1500kg, front & rear mesh doors with ≥80% ventilation rate, electrostatic spray coating, cold aisle sealing & blanking panel configuration.
- Cabinet PDU (KT-PDU-8 Port / 16S / 24S): 220VAC input, 10–16A input current, 8–24 standard 10A/16A sockets, monitors voltage/current/power with ±1% precision, RS485/TCP communication, remote control & energy consumption statistics.
6.5 Structured Cabling Products
- Twisted Pair Cable (KT-CAT5E/CAT6/CAT6A): Cat5e / Cat6 / Cat6A, 4-pair 8-core oxygen-free copper, conductor diameter 0.5–0.6mm, transmission rate 100Mbps–40Gbps, bandwidth 100–500MHz, flame-retardant PVC jacket, operating temperature -20~60℃.
- Optical Fiber (KT-FIB-SM/SMH): Single-mode, 9μm core / 125μm cladding, transmission distance 10–40km, attenuation ≤0.3dB/km, flame-retardant jacket, operating temperature -40~85℃, low loss for 10G+ transmission.
- Cable Tray (KT-QJ-200/300/400): Trough type, size 200×100–400×200mm, thickness 1.2–2.0mm cold-rolled steel, electrostatic spray / shielding ground layer, Class A fire rating, load capacity ≥50kg/m, separate routing for strong & weak current to reduce electromagnetic interference.
6.6 Environmental Monitoring Products
- Environmental Monitoring Host (KT-MON-100/500/1000): 10–21-inch touch screen, quad-core processor, 4G RAM, 128G storage, Modbus/SNMP/HTTP protocols, supports 10–100 sensor channels, local + cloud dual storage, digital twin visualization & AI early warning.
- Temperature & Humidity Sensor (KT-TH-01/02/03): Temp range -50~100℃, precision ±0.1–0.5℃; RH 0–100% RH, precision ±1–3% RH, RS485/4–20mA output, operating temperature -40~80℃, high-precision & explosion-proof optional.
- Water Leak Detector (KT-LD-01/02/03): Sensing cable length 5–50m, detection precision ≤0.1–1mm, response time <1–3s, switch/RS485 signal output, operating temperature -20~60℃, positioning & video linkage available.
6.7 Fire Protection Products
- Heptafluoropropane Fire Suppression Unit (KT-FM-40L/120L/200L): Heptafluoropropane agent, capacity 40–200L, extinguishing concentration ≤8%, auto/manual/emergency activation, startup time <30s, working pressure 1.2MPa, non-corrosive & electrically insulating for precision IT equipment.
- Smoke/Heat Detector (KT-YG-01/KT-YW-01): Photoelectric / composite smoke & heat sensing, response <5–10s, operating voltage 12–24VDC, adjustable sensitivity, switch signal output, explosion-proof design with linkage alarm function.
6.8 Security Products
- Access Control Terminal (KT-MJ-01/02/03): Card swiping / face / fingerprint / iris recognition, unlock response <0.3–1s, storage capacity 1000–10000 user credentials, RS485/TCP communication, remote authorization & full access log tracking.
- Network Camera (KT-CAM-1080P/4K/8K): Resolution 1080P–8K, 4–12mm lens, infrared night vision distance 10–50m, IP66 waterproof & dustproof, H.265 compression, 1T–4T storage, AI intelligent analysis & encrypted video storage.
- Infrared Detector (KT-HW-01/02): Detection distance 10–15m, detection angle 120°–150°, operating voltage 12–24VDC, switch signal output, anti-interference with AI false alarm filtering.
7. Full Product Application Scope
7.1 Architectural Decoration Products
- All-Steel Anti-Static Floor: Widely used in computer rooms, data centers, server rooms, communication equipment rooms, precision instrument labs and control centers requiring strict anti-static performance.
- Fireproof Metal Wall Panels & Microporous Sound-Absorbing Ceilings: Applicable to computer rooms, data centers, power distribution rooms, battery rooms, monitoring centers and office zones requiring fire resistance, dust/moisture resistance and noise reduction.
7.2 Power Supply & Distribution Products
- UPS & Storage Batteries: Deployed in financial, securities, government, education, medical and internet enterprise computer rooms, data centers, servers, storage equipment, precision instruments and emergency lighting systems requiring uninterrupted power supply.
- Precision Power Distribution Cabinets: Suitable for data centers, computer rooms, large office buildings, factories and hospitals demanding refined power distribution & real-time monitoring.
- Diesel Generator Sets: Used in Class A data centers, hospitals, banks, government agencies and large shopping malls as emergency standby power with ultra-high power reliability requirements.
7.3 Cooling & Heat Dissipation Products
- Precision Air Conditioners & Fresh Air Units: Extensively applied in computer rooms, data centers, communication rooms, labs, precision instrument rooms, museums and archives requiring constant temperature, humidity and clean air.
- Liquid Cooling Systems: Designed for high-density computing data centers, AI computing clusters and supercomputers with extreme heat dissipation demands.
7.4 Cabinet & Supporting Products
- Server & Network Cabinets: Used in data centers, enterprise network centers, communication base stations and monitoring centers for mounting servers, storage, switches and routers.
- Cabinet PDUs: Matched with all types of server/network cabinets to provide stable power supply and remote control, widely deployed in data centers, computer rooms and office network infrastructure.
7.5 Structured Cabling Products
- Twisted Pair, Optical Fiber & Cable Trays: Applied in data center cabling projects, office buildings, factories, schools, hospitals and residential communities for network communication and weak current system construction.
7.6 Environmental Monitoring Products
- Monitoring Hosts & Sensors: Suitable for data centers, computer rooms, power distribution rooms, battery rooms, communication base stations, transformer substations and factory workshops requiring 24-hour environmental & equipment monitoring.
7.7 Fire Protection Products
- Heptafluoropropane Suppression Units & Detectors: Deployed in computer rooms, data centers, power distribution rooms, battery rooms, archives, museums and precision instrument labs for targeted fire protection of valuable equipment & documents.
7.8 Security Products
- Access Control, Cameras & Infrared Detectors: Widely used in computer rooms, data centers, office buildings, factories, schools, hospitals, residential compounds, shopping malls, banks and government agencies for personnel access management and perimeter security defense.
8. Full Product Competitive Advantages
8.1 Core Brand Advantages
KITOZER integrates R&D, production, sales and after-sales service for computer room infrastructure with over 15 years of industry experience. The factory covers 50,000㎡ with an annual output of more than 100,000 sets of equipment. It holds ISO9001 quality management, ISO14001 environmental management, CE and 3C certifications. All products are independently developed and manufactured, supporting customized design, OEM/ODM confidential production, sufficient spot inventory and short delivery cycles.
8.2 Architectural Decoration Product Advantages
- All-Steel Anti-Static Floor: High load capacity, stable anti-static performance, wear & corrosion resistance, easy installation & maintenance, premium cold-rolled steel with electrostatic coating, service life ≥15 years, customizable size, color and veneer materials.
- Fireproof Metal Wall Panels & Microporous Ceilings: Class A fire rating, thermal insulation, dust & moisture resistance, noise reduction, durable & easy to clean, antibacterial coating inhibits microbial growth, modular design for fast installation and reusable disassembly.
8.3 Power Supply & Distribution Product Advantages
- UPS Uninterruptible Power Supply: Online double-conversion design outputs pure sine wave with high voltage stabilization precision and strong overload resistance; modular N+1 redundancy & parallel expansion support seamless failover without business interruption; intelligent remote monitoring, energy efficiency ≥95%.
- Storage Batteries: Sealed VRLA design with maintenance-free operation and no water refilling; colloid batteries deliver superior low-temperature performance and long cycle life; flame-retardant housing eliminates leakage risks, customizable voltage & capacity for all UPS models.
- Precision Power Distribution Cabinets: Real-time monitoring of voltage/current/power/harmonics, branch circuit fault isolation, remote switch control for refined power management; premium components for long service life & stable operation.
8.4 Cooling & Heat Dissipation Product Advantages
- Precision Air Conditioners: Ultra-accurate constant T&RH control (±0.5℃ temp, ±3% RH), variable frequency energy saving reducing power consumption by over 30%; row-level design close to heat sources improves cooling efficiency, linkage with environmental monitoring for automatic operation adjustment.
- Liquid Cooling Systems: Far higher heat dissipation efficiency than air cooling, ideal for high-density computing clusters; PUE ≤1.1 delivers outstanding energy savings to cut long-term operating costs; closed circulation design prevents dust & moisture ingress to extend equipment lifespan.
8.5 Cabinet & Supporting Product Advantages
- Server Cabinets: High-strength cold-rolled steel with maximum load capacity up to 1500kg; mesh doors with ≥80% ventilation rate for efficient heat dissipation; cold aisle sealing reduces cold air loss and energy consumption; modular accessories for flexible layout, customizable dimensions & colors.
- Intelligent Cabinet PDUs: Remote power switch/restart & energy consumption statistics, multi-layer overvoltage/overload/short-circuit protection, aluminum housing for fast heat dissipation, customizable socket quantity & types for all IT equipment.
8.6 Structured Cabling Product Advantages
- Twisted Pair & Optical Fiber Cables: Oxygen-free copper conductors deliver stable transmission with low signal attenuation; flame-retardant outer jackets improve safety, supports 10G–40G ultra-high bandwidth for future system upgrades, strong anti-electromagnetic interference performance.
- Cable Trays: Trough design organizes cables neatly for convenient maintenance; integrated shielding ground layer eliminates signal interference, durable cold-rolled steel with long service life, modular splicing for fast installation and customizable dimensions.
8.7 Environmental Monitoring Product Advantages
- Environmental Monitoring System: Multi-protocol compatibility to connect all types of equipment; digital twin visualization for intuitive room status display; AI early warning predicts potential faults to minimize downtime; local + cloud dual storage ensures data integrity, mobile APP remote real-time monitoring.
- Sensors: High measurement precision with fast abnormal response, explosion-proof design adapts to harsh environments, stable performance with long maintenance-free service life.
8.8 Fire Protection Product Advantages
- Heptafluoropropane Suppression Units: Fast fire suppression with zero residual pollution and electrical insulation, no corrosion to precision IT equipment; dual auto/manual activation for safe operation, pipe-free models with simple installation and low maintenance cost.
8.9 Security Product Advantages
- Access Control Terminals: Multi-biometric recognition for high security, ultra-fast unlock response, flexible remote access authorization, complete access logs for traceability.
- Network Cameras: High-definition imaging with infrared night vision for 24-hour surveillance; AI intelligent analysis detects human faces, abnormal behaviors and security hazards; encrypted video storage ensures data security, IP66 waterproof & dustproof for all deployment environments.
8.10 Customization & After-Sales Service Advantages
- Customization Service: All products support customized dimensions, specifications, colors and functional modules to meet personalized scenario requirements.
- OEM/ODM Service: Confidential OEM & ODM manufacturing to protect client intellectual property rights.
- Spot Inventory: Core products stocked in large quantities for immediate delivery and shortened lead time.
- Full-Cycle Integrated Service: One-stop support covering planning, design, supply, construction, commissioning, staff training and after-sales maintenance with dedicated professional teams and 7×24-hour technical support.
9. Bid Tender Control Parameters (Marked with *)
9.1 Architectural Decoration Products
- All-steel anti-static floor load ≥8kN/㎡ (Basic), ≥12kN/㎡ (Medium), ≥16kN/㎡ (High-End)
- All-steel anti-static floor grounding resistance ≤1Ω (Basic), ≤0.5Ω (Medium), ≤0.3Ω (High-End)
- Fireproof metal wall panel Class A fire rating, thermal conductivity ≤0.03W/m·K (Medium), ≤0.02W/m·K (High-End)
- Microporous ceiling noise reduction coefficient ≥0.6 (Medium), ≥0.8 (High-End)
9.2 Power Supply & Distribution Products
- UPS power factor ≥0.8, output voltage precision ±1%
- UPS supports N+1 redundancy (Medium), parallel expansion (High-End)
- Storage battery cycle life ≥500 times (Medium), ≥1000 times (High-End)
- Precision power distribution cabinet monitoring precision ±0.5% with remote control function
- Diesel generator auto-start delay ≤10s (High-End)
9.3 Cooling & Heat Dissipation Products
- Precision air conditioner temperature control precision ±0.5℃, RH precision ±3% RH
- Variable frequency precision air conditioner reduces energy consumption by ≥30% (Medium & High-End)
- Fresh air unit filter grade G4 (Basic), H13 (High-End)
- Liquid cooling system PUE ≤1.1 (High-End)
9.4 Cabinet & Supporting Products
- Server cabinet load capacity ≥800kg (Basic), ≥1000kg (Medium), ≥1500kg (High-End)
- Server cabinet front & rear mesh door ventilation rate ≥80%
- Cabinet PDU supports remote control & energy consumption statistics (Medium & High-End)
9.5 Structured Cabling Products
- Twisted pair oxygen-free copper conductor, transmission rate ≥100Mbps (Basic), ≥10Gbps (Medium), ≥40Gbps (High-End)
- Optical fiber transmission distance ≥10km (Medium), ≥40km (High-End)
- Cable tray with shielding ground layer, Class A fire rating
9.6 Environmental Monitoring Products
- Environmental monitoring host supports Modbus/SNMP protocols (Medium & High-End)
- T&H sensor precision ±0.5℃/±3% RH (Basic), ±0.1℃/±1% RH (High-End)
- Water leak detector response time ≤3s (Basic), ≤1s (High-End)
- Environmental monitoring system with digital twin visualization & AI early warning (High-End)
9.7 Fire Protection Products
- Heptafluoropropane suppression unit extinguishing concentration ≤8%, startup time ≤30s
- Smoke & heat composite detector response time ≤5s (High-End)
9.8 Security Products
- Access control supports multi-biometric recognition (Medium & High-End), unlock response ≤1s
- Camera resolution ≥1080P (Basic), ≥4K (Medium), ≥8K (High-End)
- Camera with AI intelligent analysis function (High-End)
10. Full Product Solution Portfolio
10.1 Small & Medium Enterprise Computer Room Solution (Basic Tier, Class C)
Designed for 10–30㎡ small computer rooms with limited budgets and basic operational demands, this solution adopts full-range KITOZER basic-tier products to build a fundamental reliable computer room environment. Core Configuration: 3KVA UPS + 12V100AH batteries, 5KW precision air conditioner, 42U standard cabinets, basic environmental monitoring, heptafluoropropane fire suppression, card swipe access control + HD cameras. Solution Advantages: Low cost, fast deployment, simple operation & maintenance, meets basic stable operation requirements for small enterprise IT equipment and ensures data security.
10.2 Medium Institution Computer Room Solution (Medium Tier, Class B)
Suitable for 30–100㎡ medium computer rooms of mid-sized enterprises, education, medical and scientific research institutions requiring redundant backup and stable continuous operation. Adopts full KITOZER medium-tier products for redundant reliable infrastructure. Core Configuration: 10KVA dual hot-standby UPS + 12V150AH batteries, 12KW row-level precision air conditioner + fresh air unit, cold aisle 42UC cabinets, intelligent environmental monitoring, pipe network heptafluoropropane fire suppression, face & card dual-recognition access control + 4K cameras. Solution Advantages: Redundant key equipment, high integration, intelligent monitoring & energy efficiency, automatic failover upon faults, PUE ≤1.4 to guarantee non-stop business operation.
10.3 Large-Scale Data Center Solution (High-End Tier, Class A)
Built for 100㎡+ large data centers of financial institutions, government departments and large internet enterprises requiring fault-tolerant non-stop operation and high-density computing power, this high-end KITOZER solution delivers intelligent, fault-tolerant and energy-efficient computer room infrastructure. Core Configuration: 40KVA modular N+1 redundant UPS + 12V200AH colloid batteries, 25KW variable-frequency row-level air conditioners + total heat recovery fresh air units, liquid cooling systems, fully sealed cold aisle 42UH cabinets, digital twin environmental monitoring, zoned pipe network fire suppression, multi-biometric access control + 8K AI cameras, 200KW diesel generator set. Solution Advantages: Full-system redundancy, visual intelligent management, AI predictive fault warning, ultra-low energy consumption (PUE ≤1.1), optimized for high-density computing clusters, 7×24-hour zero-interruption operation to meet maximum reliability requirements of core business systems.
10.4 Modular Micro Data Center Solution
Tailored for medium & large computer rooms demanding rapid deployment and modular expansion, the KITOZER micro data center integrates cabinets, UPS, air conditioners, monitoring and cabling into a standardized single module. Core Configuration: Cold aisle cabinets, modular UPS, row-level air conditioners, intelligent PDUs, integrated environmental monitoring, fire & security systems. Solution Advantages: Pre-manufactured and pre-commissioned in factory, on-site deployment cycle reduced by 75%, modular capacity expansion, high integration and easy maintenance, supports flexible scaling alongside business growth.
10.5 Containerized Computer Room Solution
Designed for field sites, temporary computer rooms, disaster recovery centers and remote locations, the prefabricated KITOZER containerized computer room is fully assembled and tested in factory before transportation to the deployment site. Core Configuration: Container enclosure, anti-static floor, cabinets, UPS, precision air conditioners, environmental monitoring, fire & security systems, complete cabling infrastructure. Solution Advantages: Ultra-fast on-site deployment (only water & power connection required), wide environmental adaptability (-40℃~50℃), relocatable & reusable, high safety reliability, ideal for field operations, temporary disaster recovery and emergency command scenarios.
11. Real-World Application Cases
11.1 Financial Industry Case – Branch Computer Room of a Guangdong Bank
- Project Scale: 80㎡ Class B computer room, medium-tier configuration
- Core Products: KITOZER 10KVA dual hot-standby UPS, 12KW row-level precision air conditioners, cold aisle cabinets, intelligent environmental monitoring, pipe network heptafluoropropane fire suppression, face recognition access control + 4K surveillance cameras
- Project Outcomes: Stable operation for 5 consecutive years without major failures, PUE controlled at 1.35, redundant power supply ensures uninterrupted financial services, intelligent monitoring delivers real-time fault alerts and improves maintenance efficiency by 50%, fully meets the high stability & security standards of the financial industry.
11.2 Education Industry Case – AI Computing Center of Shenzhen University of Technology
- Project Scale: 200㎡ Class A computer room, high-end tier configuration
- Core Products: KITOZER 40KVA modular UPS, 25KW variable-frequency row-level air conditioners, liquid cooling heat dissipation systems, fully sealed cold aisle cabinets, digital twin environmental monitoring, zoned fire suppression systems, multi-biometric access control
- Project Outcomes: Resolves heat dissipation bottlenecks for high-density AI computing clusters with PUE maintained at 1.12, digital twin platform realizes full-system visual management, AI early warning predicts potential faults in advance to ensure stable & efficient operation of the university’s high-performance computing center.
11.3 Government Industry Case – Computer Room Renovation for Heyuan Armed Police Detachment
- Project Scale: 50㎡ Class B computer room, medium-tier configuration
- Core Products: KITOZER high/low voltage distribution cabinets, 10KVA UPS, precision air conditioners, standard server cabinets, environmental monitoring, heptafluoropropane fire suppression, full security system
- Project Outcomes: Eliminates historical issues including unstable power supply, out-of-control temperature & humidity and lack of monitoring after upgrading the legacy computer room. The system operates stably and complies with data security & business continuity requirements of armed police business, passing official acceptance with excellent feedback.
11.4 Enterprise Case – Headquarters Computer Room of Kinchengda Group
- Project Scale: 120㎡ Class A computer room, high-end tier configuration
- Core Products: KITOZER modular UPS, row-level precision air conditioners, cold aisle cabinets, integrated environmental monitoring, full fire & security systems
- Project Outcomes: Modular design saves 30% floor space and shortens deployment cycle by 60%, intelligent operation platform enables full remote management, PUE ≤1.2 delivers remarkable energy savings, fully supports core business operation of the corporate headquarters.
11.5 Medical Industry Case – Computer Room of a Grade A Tertiary Hospital in Guangzhou
- Project Scale: 60㎡ Class B computer room, medium-tier configuration
- Core Products: KITOZER UPS, precision air conditioners, server cabinets, environmental monitoring, fire protection & access control systems
- Project Outcomes: Ensures 7×24-hour uninterrupted operation of core hospital systems including HIS, electronic medical records and medical imaging platforms, stable temperature & humidity environment safeguards data integrity, provides reliable infrastructure support for hospital digital transformation.
12. Common Equipment Faults & Maintenance Guidelines
12.1 Power Supply & Distribution System
Common Faults
- UPS fails to boot: Municipal power outage, damaged batteries, tripped input circuit breaker, mainboard failure
- Abnormal UPS output: Unstable voltage, frequency deviation, power cut-off, overload protection trigger
- Swollen / leaking batteries: Overcharging, over-discharging, aging, excessive ambient temperature
- Distribution cabinet tripping: Short circuit, overload, electric leakage, component damage
Maintenance Schedule
- Daily Inspection: Check UPS operating status, voltage/current/temperature readings, battery appearance and cabinet indicator lights, record operational data.
- Monthly Maintenance: Remove dust from UPS and distribution cabinets, fasten wiring terminals, test battery voltage & internal resistance, calibrate system parameters.
- Quarterly Maintenance: Conduct 80% load 2-hour UPS endurance test, power switching test, inspect cooling fans, replace aging components.
- Annual Overhaul: Deep internal cleaning, full battery capacity testing, calibration of precision distribution cabinet monitoring parameters, full-system joint debugging.
12.2 Cooling & Heat Dissipation System
Common Faults
- Air conditioner no cooling: Compressor failure, refrigerant leakage, clogged filter, damaged fan, faulty T&H sensor
- Abnormal temperature & humidity: Inaccurate sensor readings, incorrect AC settings, cold/hot aisle air short-circuit, faulty fresh air unit
- Water leakage: Clogged condensate drain pipe, loose pipe joints, excessive frost melting on evaporator
Maintenance Schedule
- Daily Inspection: Check air conditioner operation, indoor T&H, pipeline pressure and water leakage risks, record data.
- Monthly Maintenance: Clean air filters, evaporators and condensers, inspect fan operation, fasten wiring terminals.
- Quarterly Maintenance: Test refrigerant pressure, top up refrigerant as required, calibrate T&H sensors, verify linkage control functions.
- Annual Overhaul: Deep internal cleaning, inspect compressor & fan bearings, replace aging parts, calibrate overall cooling performance.
12.3 Environmental Monitoring System
Common Faults
- Monitoring host offline: Network disconnection, power failure, mainboard breakdown, software crash
- No data feedback from sensors: Loose wiring, damaged sensors, communication failure, abnormal power supply
- False / missed alarms: Inaccurate sensor calibration, incorrect threshold settings, software malfunction
Maintenance Schedule
- Daily Inspection: Check monitoring host operation, network connectivity, online sensor status and historical alarm logs.
- Monthly Maintenance: Clean sensor dust deposits, fasten wiring connections, calibrate sensor parameters, back up monitoring data.
- Quarterly Maintenance: Test all alarm functions, verify equipment linkage logic, update system software, optimize alarm threshold settings.
- Annual Overhaul: Full hardware inspection, replace aging sensors, full-system joint debugging, data recovery simulation test.
12.4 Fire Protection System
Common Faults
- False detector alarms: Dust accumulation, smoke interference, sensor aging, incorrect sensitivity
- Suppression unit fails to activate: Power failure, insufficient starter cylinder pressure, linkage circuit fault, expired fire suppression agent
- Fire alarm control panel failure: No signal output, abnormal indicator lights, disabled linkage functions
Maintenance Schedule
- Daily Inspection: Check detector status, alarm panel indicators and suppression cylinder pressure, record data.
- Monthly Maintenance: Clean detector dust, test alarm trigger functions, inspect linkage wiring, fasten terminals.
- Quarterly Maintenance: Simulate suppression unit activation test, check agent expiration date, replenish starter gas as required.
- Annual Overhaul: Full fire system inspection, replace aging detectors, test & replace fire suppression agent, full linkage simulation test.
12.5 Security System
Common Faults
- No camera video feed: Power failure, network disconnection, lens obstruction, damaged camera hardware
- Access control cannot unlock: Recognition failure, power cut, broken lock body, faulty controller
- Infrared detector false alarms: Small animal interference, ambient temperature fluctuation, sensor aging
Maintenance Schedule
- Daily Inspection: Check camera video quality, access control status, detector indicator lights and video recording integrity.
- Monthly Maintenance: Clean camera lenses, access control recognition panels and detector surfaces, fasten wiring terminals.
- Quarterly Maintenance: Test access recognition sensitivity, camera night vision performance and detector alarm response, update device firmware.
- Annual Overhaul: Full security hardware inspection, replace aging components, back up surveillance storage data, full-system linkage test.
12.6 Cabinets & Structured Cabling System
Common Faults
- Cabinet static electricity buildup: Poor grounding, floor static leakage, equipment electric leakage
- Cable faults: Open circuit, short circuit, poor contact, aging & damaged outer jacket
- Disorganized cabling: Unmarked tangled cables blocking cabinet airflow and heat dissipation
Maintenance Schedule
- Daily Inspection: Check cabinet grounding, cable connection integrity, cable tidiness and internal equipment operating temperature.
- Monthly Maintenance: Remove cabinet dust, reorganize messy cables, add identification labels, test grounding resistance.
- Quarterly Maintenance: Test cable continuity, replace aged damaged cables, fasten cable managers & support trays.
- Annual Overhaul: Full cable rearrangement, replace aging cable trays & trunking, cabinet anti-rust treatment, re-test full grounding system resistance.
13. Factory Strength & After-Sales Service
13.1 Factory Strength
KITOZER boasts over 15 years of R&D and manufacturing experience in computer room infrastructure, with a production base in Guangzhou covering 50,000㎡ (30,000㎡ building area), more than 500 staff including a 50+ professional R&D team, and an annual output of over 100,000 sets of equipment.
- Production Equipment: Imported German CNC punching machines, laser cutters, bending machines, automatic coating lines and automated assembly lines deliver high-precision, efficient and consistent manufacturing quality.
- R&D Capability: Independent development of core products including UPS, precision air conditioners, environmental monitoring and cabinets, holding over 50 patents and software copyrights with continuous technological innovation aligned with industry trends.
- Quality Control: Strict compliance with ISO9001 quality, ISO14001 environmental, CE and 3C certification standards. Raw material screening, full-process production inspection and 100% finished product testing before delivery guarantee stable product quality.
- Supply Chain: Long-term strategic cooperation with well-known domestic & international component suppliers ensures stable supply and premium raw material quality.
13.2 After-Sales Service
Service Commitments
- Warranty Period: 3-year full product warranty, 5-year warranty for core components; free repair & component replacement plus full technical support during warranty coverage.
- Response Time: 7×24-hour technical hotline with ≤10-minute phone response, ≤30-minute remote fault diagnosis, on-site service within 4 hours for Guangdong Province and within 24 hours nationwide.
- Lifetime Maintenance: Discounted maintenance services after warranty expiration, free technical consultation & software upgrades, only component cost charged for replacements.
Standard Service Process
- Fault Reporting: Customers submit work orders via service hotline or online channels with fault description, equipment model and site address.
- Remote Troubleshooting: Engineers respond within 10 minutes, conduct remote diagnosis via phone & desktop sharing and provide solutions within 30 minutes.
- On-Site Support: If remote resolution fails, local service engineers are dispatched immediately to arrive within the promised time frame for inspection, repair & equipment recovery.
- Acceptance & Follow-Up: Customers sign acceptance forms after repair completion, with follow-up calls within 24 hours to confirm stable equipment operation and collect feedback.
Value-Added Services
- Free On-Site Training: Post-delivery hands-on operation & maintenance training for customer operation & maintenance teams to master equipment daily management.
- Scheduled Inspection Services: Quarterly / annual proactive inspection packages to identify hidden faults and reduce downtime risks.
- Customized VIP Support: Tailored operation & maintenance plans, dedicated technical account managers and priority VIP service channels for enterprise clients.
14. Conclusion
Integrated computer room construction forms the core infrastructure foundation of data center and enterprise informatization projects, directly determining IT equipment operational stability, data security and business continuity. Backed by over 15 years of industry expertise, full-range independent R&D & manufacturing capacity, mature solution portfolio and comprehensive after-sales system, KITOZER delivers one-stop full-cycle services covering planning, design, supply, construction, commissioning and long-term operation & maintenance.
This solution provides three tiered configurations (basic, medium, high-end) to match computer room construction projects of varying scales, industries and budgets, integrating design concepts of energy efficiency, intelligent operation, high safety and modular expandability while strictly complying with national industry standards to ensure stable, efficient and secure long-term computer room operation.
Moving forward, KITOZER will continue technological innovation to optimize products and solutions, following the industry trends of green, intelligent and high-density data center development, and provide higher-quality, more efficient and reliable computer room infrastructure and services to support digital transformation and high-quality development across all industries.
15. SEO Optimization Keywords & Tags
15.1 Core Keyword System
Primary Core Keywords
Integrated computer room construction, KITOZER computer room solution, data center construction, computer room system integration
High-Conversion Long-Tail Keywords
Small & medium enterprise computer room construction solution, Class B computer room integrated design, Class A data center solution, computer room UPS & precision air conditioner configuration, computer room environmental monitoring system, computer room fire & security system, modular micro data center construction, containerized computer room solution
Industry Traffic Keywords
Computer room construction, server room integration, financial computer room solution, education computer room construction, government computer room renovation, medical computer room design, computer room decoration engineering, computer room power supply & distribution system, computer room cooling system, computer room structured cabling
Brand Exclusive Keywords
KITOZER computer room equipment, KITOZER UPS power supply, KITOZER precision air conditioner, KITOZER server cabinet, KITOZER environmental monitoring, KITOZER fire protection equipment, KITOZER security equipment
Search Suggestion Keywords
GB50174 computer room standard, data center PUE optimization, computer room cold & hot aisle isolation, redundant power supply design for computer rooms, intelligent computer room operation & maintenance, high-density computing cooling solution
15.2 SEO Optimization Tag System
Core Page Title Tag
Integrated Computer Room Construction Solution_KITOZER Data Center Construction System Integration Plan
Title Label
Integrated Computer Room Construction Solution | KITOZER Data Center Building | Computer Room System Integration Design
Meta Keywords
Integrated computer room construction, KITOZER computer room solution, data center construction, computer room system integration, small & medium enterprise computer room construction, Class B computer room design, Class A data center plan, computer room UPS configuration, computer room environmental monitoring, computer room fire & security
Meta Description
KITOZER delivers professional integrated computer room construction solutions covering architectural decoration, power supply & distribution, cooling, cabinets, structured cabling, environmental monitoring, fire protection and security systems. Three tiered configurations support small & medium enterprises, large institutions and data center projects. We own robust manufacturing capacity and complete after-sales service to guarantee stable & efficient computer room operation for all industries.
H1 Header Tag
Integrated Computer Room Construction Solution
H2 Header Tags
System Overview, System Composition, System Classification, System Schematic Logic, Full System Configuration List, Full Product Technical Specifications, Full Product Application Scope, Full Product Competitive Advantages, Bid Tender Control Parameters, Full Product Solution Portfolio, Real-World Application Cases, Common Equipment Faults & Maintenance Guidelines, Factory Strength & After-Sales Service, Conclusion
Internal Link Anchor Text Tags
- Core Anchor Text: Integrated computer room construction, KITOZER computer room solution, data center construction
- Long-Tail Anchor Text: Small & medium enterprise computer room construction solution, Class A data center solution, computer room environmental monitoring system, modular micro data center construction
- Related Anchor Text: Computer room power supply & distribution system, computer room cooling system, computer room structured cabling, computer room fire & security system