Integrated Fire Suppression Linkage for Data Centers | KITOZER

Product Overview

Our integrated fire suppression linkage system is a comprehensive fire protection solution designed specifically for data centers and computer rooms. It combines high-sensitivity detection, clean agent gas suppression, and intelligent linkage with power, cooling, access control, and environment monitoring systems to ensure early detection, precise extinguishing, and minimal equipment damage. With strict compliance to national fire codes and multiple activation modes, it provides reliable safety for critical facilities.

Product Introduction

The integrated fire suppression linkage system is an intelligent fire protection solution engineered for data center environments. Centered on a clean agent gas suppression system, it integrates fire detection, alarm control, extinguishing execution, linkage control, and emergency evacuation functions. In the event of a fire, the system achieves early detection, precise alarm, and automatic extinguishing while coordinating with the data center’s power distribution, air conditioning, access control, and environment monitoring systems – all designed to protect personnel safety and minimize equipment damage, ensuring business continuity.

Product Positioning

This system is positioned as the core safety guarantee for data center fire protection. It is strictly designed according to fire protection regulations and is suitable for various scenarios where water-based fire suppression is inappropriate, including data rooms, power distribution rooms, and precision equipment rooms. As an essential safety system for data center construction, it provides reliable fire protection for critical equipment and data.

Core Value

  • Early Warning: High-sensitivity fire detection to identify fire hazards in the earliest stage.
  • Precise Extinguishing: Clean agent gas extinguishes fires without damaging equipment, offering high efficiency.
  • Linked Protection: Automatically coordinates with multiple data center systems – cutting power, closing air conditioning, and preventing fire spread.
  • Compliance: Meets national fire protection standards and passes fire department acceptance.
  • Safe & Reliable: Multiple protective mechanisms ensure personnel safety and prevent accidental discharge.

Product Highlights

  • Multi-system Linkage: Seamless integration with power distribution, air conditioning, access control, and environment monitoring for fully automated fire response.
  • Multi-sensor Detection: Combined smoke, heat, and infrared detection minimizes false alarms.
  • Clean Extinguishing: Uses HFC-227ea (seven-fluoropropane) or IG541 – residue-free and safe for electronic equipment.
  • Triple Activation: Automatic, manual electrical, and mechanical emergency start options guarantee extinguishing reliability.
  • Full-time Monitoring: Fire status is integrated into the environment monitoring platform for visual management.

System Classification and Composition

Product Classification

  • By extinguishing agent: HFC-227ea (seven-fluoropropane) gas suppression system, IG541 mixed gas suppression system, aerosol suppression system.
  • By installation type: cabinet-type gas suppression, piped network gas suppression, and suspended suppression devices.
  • By protection zone: single-zone fire suppression system, multi-zone combined distribution system.

System Composition

  • Fire Detection System: Point-type photoelectric smoke detectors, point-type heat detectors, infrared flame detectors.
  • Alarm Control System: Gas suppression controller, emergency start/stop buttons, audible & visual alarms, discharge indicator lights.
  • Extinguishing Execution System: Agent storage cylinders, container valves, selector valves, piping network, nozzles.
  • Linkage Control System: Linkage control modules for power, air conditioning, access control, and fresh air coordination.
  • Emergency Evacuation System: Emergency lighting, evacuation sign indicators.
  • Monitoring Interface Module: Interfaces with environment monitoring platform for remote status monitoring.

System Principle

The system operates on a “detect – alarm – delay – extinguish – link” logic. When a fire occurs in the protected zone, smoke and heat detectors simultaneously sense the fire condition. The controller triggers audible and visual alarms, starts a 30-second delay countdown, and simultaneously sends linkage signals to cut non-emergency power, shut down precision air conditioning and fresh air systems, and close fire doors for personnel evacuation. After the delay, the agent cylinders are activated, and gas is delivered through the piping network to flood the protected area, rapidly extinguishing the fire. Throughout the process, system status is uploaded to the environment monitoring platform for remote monitoring and alerts. The system also supports manual start, emergency stop, and mechanical emergency activation, ensuring both extinguishing reliability and personnel safety.

Technical Parameters

Parameter Specification Remarks
———– ————— ———
Fire response time Smoke & heat combined alarm ≤10s, discharge delay 0-30s adjustable Standard delay 30s
Flooding time HFC-227ea: electronic equipment room ≥5min Per GB50370
Working pressure HFC-227ea: 2.5MPa / 4.2MPa / 5.6MPa Stored at room temperature
Operating temperature 0℃~50℃ Indoor environment
Detection sensitivity Smoke: obscuration 0.5~10%/m adjustable Per GB4715
Linkage output Dry contacts, multiple loop outputs Customizable quantity
Activation methods Automatic, electrical manual, mechanical emergency Triple activation
Agent shelf life HFC-227ea ≥10 years Periodic pressure check
Power supply AC220V, backup DC24V, backup time ≥8h Per fire code

Configuration List

No. Product Name Specifications Unit Qty Notes
—– ————– —————- —— —– ——-
1 Gas suppression controller Single-zone/multi-zone, DC24V backup Unit As needed 3C certified
2 Photoelectric smoke detector Point type, addressable Piece As needed 1 per 10-15㎡
3 Heat detector Point type, fixed temp 68℃ Piece As needed Paired with smoke
4 HFC-227ea cylinder set 70L/100L/120L, with agent Cylinder As needed Based on volume
5 Cabinet-type suppression unit Single/twin cylinder, with cabinet Set As needed No piping
6 Audible & visual alarm Fire alarm, addressable Piece As needed Inside/outside zone
7 Emergency start/stop button Fire protection, with cover Piece As needed Outside zone door
8 Discharge indicator 24V, fire protection Piece As needed Outside zone door
9 Selector valve For piping zones Piece As needed For network systems
10 Linkage module Input/output, dry contacts Piece As needed For other systems

Materials & Process

Material Details

  • Agent cylinders: High-quality seamless steel tubes, galvanized inside and outside for corrosion resistance and high pressure capability, compliant with pressure vessel standards.
  • Extinguishing agent: HFC-227ea clean gas, non-toxic, non-corrosive, good insulation, residue-free after discharge, safe for electronic equipment.
  • Piping network: Seamless steel tubes, galvanized, pressure and corrosion resistant, reliable sealing.
  • Detector housing: ABS flame-retardant engineering plastic, industrial-grade chips, stable performance.
  • Controller shell: Cold-rolled steel, electrostatic spray coating, corrosion and interference resistant, compliant with fire equipment standards.

Core Process Description

  • Pressure vessel welding: Automatic welding process ensures uniform seams; hydraulic and air-tightness tests guarantee pressure safety.
  • Sealing process: Dedicated seals and sealants at valves and pipe joints ensure zero leakage and stable long-term storage pressure.
  • Surface treatment: Galvanizing + powder coating double anti-corrosion treatment for data center environments, extending service life.
  • System commissioning: Professional fire commissioning personnel perform simulated discharge and linkage tests per standards.
  • Detector calibration: Sensitivity calibrated at factory, functional test after on-site installation.

Safety Certifications

  • CCC Certification for all core fire equipment.
  • Pressure vessel testing certificate for agent cylinders.
  • ISO9001 quality management system certification.
  • Professional contracting qualification for fire protection works.
  • Maintenance & testing qualification for fire protection facilities.

Core Advantages

Material Advantage

All core fire equipment is sourced from certified brands with CCC certification. Agent purity meets standards, and pressure vessels comply with national requirements – securing the system’s safety and reliability from the source.

Process Advantage

A professional fire construction team follows strict fire codes. System commissioning is performed by certified fire engineers to ensure functionality and smooth passage of fire acceptance. Standardized procedures guarantee long-term stable operation.

Customization Advantage

Customized fire protection solutions based on room area, layout, and criticality. Supports cabinet, piped network, and suspended types. Multi-system linkage customization adapts to different data center scenarios.

Cost Advantage

Direct sourcing of fire equipment, integrated design and construction reduce intermediate costs. Optimized design controls budget while meeting specifications, delivering high-cost-performance solutions.

Quality Advantage

System design strictly follows national fire codes. Equipment is legitimate, construction and acceptance are compliant. Long-term maintenance services keep the system in compliant condition for fire inspections.

Product Categories

  • Cabinet-type HFC-227ea suppression system: No piping needed, easy installation, ideal for single protection zones in small/medium rooms.
  • Piped network HFC-227ea system: For multi-zone distribution, suited for large data centers.
  • IG541 mixed gas suppression system: Eco-friendly, for manned computer rooms, no secondary contamination.
  • Suspended gas suppression device: For small zones, simple installation, low cost.
  • Integrated linkage system: Includes detection, alarm, suppression, and full system linkage – delivered as a turnkey solution.

SKU Details

SKU Product Name Protection Zone Area System Type Applicable Scenario
—– ————– ———————- ————- ———————-
LA-XF-001 Cabinet HFC-227ea system ≤50㎡ Cabinet, no piping Small data room
LA-XF-002 Single-zone network system 50-200㎡ Piped network Medium data room
LA-XF-003 Multi-zone combined distribution Total ≥200㎡ Piped network Large data center
LA-XF-004 IG541 gas suppression system Customized Piped network Manned data room
LA-XF-005 Suspended suppression device ≤10㎡ Suspended Small electrical room

Stock Details

  • Common cabinet-type suppression units, detectors, and controllers are kept in stock.
  • Standard products ship within 3 days; network systems are built to order.
  • Adequate inventory of common fire accessories and replacement parts for after-sales support.
  • Urgent orders can be prioritized to meet project schedules.

OEM Services

  • OEM support for fire suppression systems, neutral packaging, and brand labeling.
  • Deep design and construction cooperation with integrators and engineering firms, full confidentiality.
  • Non-disclosure agreements protect client project and business information.
  • Technical support and acceptance assistance to ensure successful project delivery.

Application Scenarios

  • Data centers, server rooms, network rooms.
  • High/low voltage power distribution rooms, transformer rooms, generator rooms.
  • Precision instrument rooms, laboratories, testing rooms.
  • Archives, libraries, valuable storage rooms.
  • Telecommunication rooms, base station rooms.
  • Command centers, monitoring centers.

Customization Services

Customization Scope

  • System type: Cabinet, piped network, or suspended per requirement.
  • Agent type: HFC-227ea, IG541, aerosol, etc.
  • Linkage functions: Integration with power, HVAC, access control, environment monitoring.
  • Zone design: Optimized protection zone and piping layout based on room configuration.
  • Special scenarios: Explosion-proof, low-temperature, high-altitude adaptations.

Customization Process

  1. Needs discussion – understand room area, layout, criticality, and fire protection requirements.
  2. Solution design – produce compliant fire protection design, configuration, and quote.
  3. Solution confirmation – adjust and finalize design and budget.
  4. Detailed design – issue construction drawings and fire protection filings.
  5. Construction & installation – professional team performs on-site work.
  6. Commissioning & acceptance – system testing and assistance with fire department acceptance.
  7. Delivery & maintenance – submit documentation and enter warranty period.

Customization Advantages

  • Professional fire design team ensures compliant, reasonable designs that pass acceptance.
  • Flexible adaptation to different room layouts and requirements.
  • Full lifecycle service from design to acceptance – one-stop solution.
  • Extensive project experience across complex data center scenarios.

Success Cases

Representative Clients

  • Fire protection system for a bank’s data center.
  • Government cloud data center fire protection project.
  • Information center fire protection for a tertiary hospital.
  • University data center fire protection system.
  • Data center fire protection retrofit for a large enterprise.

Case Highlights

  • Bank data center: Used piped network HFC-227ea system with 8 protection zones in combined distribution. Full system linkage passed fire acceptance on first attempt; zero failures in 5 years.
  • Government cloud project: Integrated fire suppression with environment monitoring, power distribution, and air conditioning. Automated response and high intelligence met governmental security requirements.
  • Hospital retrofit: Completed fire system upgrade without downtime, ensuring business continuity and zero construction incidents.

Troubleshooting

Fault Type Troubleshooting Steps Resolution
———— ———————— ————
Detector false alarm 1. Check for actual fire; 2. Inspect for dust/moisture interference; 3. Check for short circuit 1. Reset controller if no fire; 2. Clean detector and remove interference; 3. Repair wiring
Low agent pressure 1. Check pressure gauge; 2. Inspect valve/piping leakage 1. Refill agent if below normal; 2. Locate and seal leaks, then recharge
Linkage failure 1. Check module wiring; 2. Verify controller programming; 3. Check linked equipment status 1. Reconnect wiring; 2. Reprogram linkage logic; 3. Repair linked equipment
Controller alarm 1. Read fault code; 2. Check main/backup power; 3. Inspect loop wiring 1. Resolve based on code; 2. Restore power and check battery; 3. Repair open/short circuits

Maintenance

Monthly Inspection

  • Verify controller status – no fault or fire alarms.
  • Check agent cylinder pressure is within normal range.
  • Inspect detectors, alarms for physical damage.
  • Confirm emergency buttons and discharge indicators are operational.

Quarterly Maintenance

  • Test detector functionality with simulated alarm.
  • Test audible/visual alarms and discharge indicators.
  • Verify linkage output and logic.
  • Test primary/backup power switching and backup battery.

Annual Maintenance

  • Full system function test with simulated discharge.
  • Weigh cylinders / check pressure, refill leaked agent.
  • Test piping airtightness to identify leaks.
  • Clean and calibrate detectors; replace aging or failed units.
  • Review controller software and conduct full functional tests.

Factory Strength & After-sales Service

Factory Strength

  • Holds professional contracting qualification for fire protection works and maintenance/testing qualification.
  • Partners with certified fire equipment brands; all products have CCC certification.
  • Employs certified fire engineers and a professional construction team with rich project experience.
  • Completed over a thousand data center fire projects, familiar with various acceptance standards.

After-sales Service

  • Overall system warranty: 1 year; core equipment per manufacturer’s standards.
  • 7×24 emergency response, prioritizing fire-related faults.
  • Annual maintenance service with regular checks to keep system compliant.
  • Provides fire operation training and guidance for daily management.
  • Supports fire department inspections and provides technical assistance.

Procurement Service Guarantees

Supply Guarantee

Authorized brand partnerships, stocked common equipment, scheduled production for custom items, ensuring project timelines. All equipment is original with complete qualification documents.

Quality Guarantee

All fire equipment holds CCC certification and test reports, compliant with national standards. Professional team follows design drawings and codes strictly to ensure project quality.

Logistics Guarantee

Professional dangerous goods transportation channels ensure compliant agent shipping. Specialized packaging prevents damage, and delivery is door-to-door for convenience.

After-sales Guarantee

Professional fire technical team responds quickly to faults. Free repair/replacement during warranty, long-term maintenance services keep the system consistently compliant.

Invoice Guarantee

Can issue 9% engineering invoices and 13% equipment VAT special invoices. Invoicing standards meet financial and project settlement requirements.

FAQ

Q: Is gas suppression mandatory for data centers?

A: Yes. Data centers contain extensive electronic equipment that cannot be extinguished with water. Clean agents like HFC-227ea are required – they leave no residue and do not damage equipment.

Q: Can the fire system integrate with environment monitoring?

A: Yes. Our integrated linkage supports interfacing with environment monitoring platforms, enabling remote status viewing and alarm notifications for improved management efficiency.

Q: Is gas suppression harmful to humans?

A: Properly designed HFC-227ea systems are harmless at design concentration. The system includes a 30-second evacuation delay, allowing personnel to safely exit.

Q: Do you handle fire acceptance?

A: Yes. We offer full-service from design through construction, commissioning, and acceptance assistance, ensuring the system meets all regulatory requirements.

Conclusion

KITOZER’s integrated fire suppression linkage system delivers comprehensive protection for data centers and critical facilities. Combining reliable clean agent suppression, intelligent multi-sensor detection, and seamless linkage with auxiliary systems, it ensures early response, minimal damage, and regulatory compliance. With certified equipment, experienced engineering, and full after-sales support, our solution is trusted across banking, government, healthcare, and enterprise sectors. Contact us today to secure your data center’s safety.

—