I. Solution Overview
Targeting the core needs of power supply stability and equipment safety during base station operation, this solution integrates the Base Station Power Supply Solution and Base Station Protection Solution to build an integrated guarantee system featuring “stable and reliable power supply, comprehensive and precise protection, efficient and convenient operation and maintenance, and adaptability to multi-scenario deployment”. Covering the entire process of system design, equipment configuration, technical implementation, and later operation and maintenance, the solution can effectively solve common problems such as mains power interruption, power supply fluctuation, lightning strike, electromagnetic interference, physical damage, and environmental erosion of base stations, ensuring 24/7 uninterrupted and safe operation of base stations. It is suitable for the deployment needs of various communication base stations (4G/5G macro base stations, micro base stations, distributed base stations, etc.), can be quickly implemented without additional modification, comprehensively improves the stability, safety and service life of base station operation, and reduces operation and maintenance costs and fault losses.
II. Search Keywords, SEO and Tags
2.1 Search Keywords (Core + Long-tail)
Core Keywords: Base Station Power Supply Solution, Base Station Protection Solution, Base Station Uninterruptible Power Supply System, Base Station Lightning Protection Solution, Base Station Comprehensive Protection System
Long-tail Keywords: Emergency Power Supply Solution for Base Station Mains Interruption, Power Supply Solution for Remote Area Base Stations, Base Station Lightning and Static Electricity Protection Technology, Base Station Equipment Physical Protection Solution, Base Station Power Supply System Stability Optimization, Base Station Protection Engineering Implementation Plan, 4G/5G Base Station Integrated Power Supply and Protection Solution, Base Station Power Supply Fault Solution, Base Station Environmental Protection System, Base Station Electromagnetic Interference Protection Solution
2.2 SEO Optimization Points
1. Natural Keyword Distribution: The core keywords appear 8-12 times in the full text, and long-tail keywords are evenly distributed in each chapter (2-3 per chapter). The frequency of keywords is appropriately increased in key chapters (Technical Solution, Product Advantages, Application Cases) to avoid stacking and ensure fluent sentences.
2. Title Optimization: The main title contains core keywords, and each level 1 and level 2 title integrates keywords with chapter content to improve the priority of search engine crawling; chapter titles are concise and clear, in line with user search habits (such as “Base Station Power Supply System Technical Solution”, “Core Advantages of Base Station Lightning Protection”).
3. Content Optimization: The core content (system introduction, technical parameters, bid control parameters, application cases) is detailed and specific, increasing the originality and practicality of the content, integrating industry technical specifications to improve content weight; key technical points, advantages and cases are presented with clear logic to facilitate search engine crawling and user reading.
4. Adaptation to External Independent Websites: The content complies with the inclusion rules of external search engines, avoids redundant information, focuses on the professionalism, comprehensiveness and implementability of the solution, and meets the search needs of overseas users (focusing on base station stable operation, multi-scenario adaptation, and compliance).
2.3 Tags
Base Station Power Supply, Base Station Protection, Base Station Uninterruptible Power Supply, Base Station Lightning Protection, Base Station Physical Protection, Base Station Electromagnetic Protection, Base Station Power Supply Solution, Base Station Protection Solution, 4G Base Station Solution, 5G Base Station Solution, Remote Base Station Power Supply, Base Station Operation and Maintenance Optimization, Base Station Equipment Protection, Base Station Power Supply Stability
III. Base Station Power Supply Solution
3.1 System Introduction
The base station power supply system is the core infrastructure to ensure the normal operation of base station equipment. It undertakes the core functions of power access, conversion, distribution, storage and emergency power supply, and can adapt to multiple power supply modes such as mains power, photovoltaic power and diesel generator, solving problems such as unstable power supply, mains power interruption and high power supply loss of base stations in different scenarios. Adopting a modular design, the system is mainly composed of five units: power access module, power conversion module, energy storage module, power distribution module and monitoring management module. Each module works collaboratively to achieve the power supply goal of “mains power priority, emergency supplementary, intelligent regulation and high efficiency and energy saving”.
Core Positioning of the System: To provide continuous, stable and precise power supply for various base station equipment (base station main equipment, transmission equipment, monitoring equipment, protection equipment, etc.). When the mains power is normal, it relies on the mains power for efficient power transmission; when the mains power is interrupted, it automatically switches to the energy storage module or backup power supply module to ensure the uninterrupted operation of core base station equipment. At the same time, it has intelligent monitoring, fault early warning and remote operation and maintenance functions, which can real-time monitor power supply parameters and equipment operation status, timely detect and warn power supply faults, and reduce operation and maintenance costs.
The system is suitable for base stations in various scenarios, including urban macro base stations, suburban micro base stations, remote mountainous area base stations, island base stations, etc. According to the power supply conditions of different scenarios (mains coverage, lighting conditions, environmental complexity), the module configuration can be flexibly adjusted to balance power supply stability and energy saving. At the same time, it complies with relevant industry power supply standards to ensure the compliance and reliability of system operation. It can effectively improve the power supply availability of base stations to more than 99.99%, solving the pain points of poor power grid coverage and low power supply reliability in remote areas.
3.2 System Configuration List (Brand: KITOZER)
| No. | Equipment Name | Brand | Specifications and Models | Quantity | Purpose |
| 1 | Mains Access Switch | KITOZER | Adapts to 380V/220V mains power, rated current 100A, protection level IP65 | 1 Unit | Access mains power, control mains on/off, with overload and short circuit protection functions |
| 2 | Rectifier Module | KITOZER | Input voltage 380V±15%, output voltage 48V, output current 50A, efficiency ≥95% | 4 Units (3 in use, 1 standby) | Convert mains AC power to DC power to supply and charge base station equipment and energy storage modules |
| 3 | Energy Storage Lithium Battery Pack | KITOZER | Cell voltage 3.2V, capacity 200Ah, cycle life ≥2000 times, operating temperature -20℃~60℃ | 1 Set (16 cells in series) | Provide emergency power supply for core base station equipment and store surplus power when mains power is interrupted |
| 4 | DC Power Distribution Screen | KITOZER | 16 output circuits, rated current 63A, with overvoltage, undervoltage and overcurrent protection | 1 Unit | Distribute the DC power output by the rectifier module to various DC equipment of the base station |
| 5 | AC Power Distribution Screen | KITOZER | Input voltage 380V, 8 output circuits, rated current 63A, with lightning protection | 1 Unit | Distribute mains AC power to supply base station AC equipment (such as air conditioners, diesel generators) |
| 6 | Intelligent Monitoring Module | KITOZER | Supports real-time monitoring of voltage, current, temperature and humidity, and can realize remote alarm and remote regulation | 1 Unit | Real-time monitor the operation status of the power supply system, collect power supply parameters, and realize fault early warning and remote operation and maintenance |
| 7 | Photovoltaic Controller (Optional) | KITOZER | Input voltage 48V, rated current 30A, supports MPPT maximum power point tracking | 1 Unit | Adapt to photovoltaic power supply mode, control photovoltaic panel charging, and improve photovoltaic power supply efficiency |
| 8 | Photovoltaic Panel (Optional) | KITOZER | Power 550W, conversion efficiency ≥23%, protection level IP67, wind resistance level 12 | 4 Pieces | Provide photovoltaic power supply and supplement electric energy for base stations in remote areas without mains power |
| 9 | Backup Diesel Generator Controller (Optional) | KITOZER | Input voltage 24V, supports automatic start and automatic stop, adapts to 5-10kW diesel generators | 1 Unit | Control the start of the backup diesel generator to supply continuous power to the system when the mains power is interrupted for a long time |
| 10 | Connecting Cables | KITOZER | Copper core, adapted to various equipment interfaces, temperature resistance -40℃~80℃, waterproof and flame-retardant | 1 Batch | Realize power transmission and signal transmission between equipment, ensuring transmission stability and safety |
| 11 | Lightning Arrester | KITOZER | Rated voltage 380V, discharge current capacity 20kA, response time ≤25ns | 2 Units | Prevent power supply equipment from being damaged by lightning overvoltage and improve the lightning protection capability of the system |
3.3 System Schematic Diagram
The base station power supply system adopts the design idea of “multi-power supply mode complementarity, intelligent switching and hierarchical protection”. The core schematic diagram is described in words below (clear and easy to understand, suitable for external display, and can be directly converted into visual drawings):
1. Mains Power Supply Circuit: Mains Power → Mains Access Switch → Lightning Arrester → AC Power Distribution Screen → Divided into two paths (one path directly supplies base station AC equipment; the other path is connected to the rectifier module to convert into DC power) → Rectifier Module → DC Power Distribution Screen → Supply base station DC equipment + Charge energy storage lithium battery pack.
2. Emergency Power Supply Circuit (When Mains Power is Interrupted): Energy Storage Lithium Battery Pack → DC Power Distribution Screen → Automatically switch to power supply mode → Supply core DC equipment of the base station; if long-term emergency is needed, the backup diesel generator (through the diesel generator controller) starts automatically → Connect to AC Power Distribution Screen → Rectifier Module → DC Power Distribution Screen power supply + Energy storage lithium battery pack charging; in remote areas without mains power, Photovoltaic Panel → Photovoltaic Controller → DC Power Distribution Screen → Power supply + Energy storage lithium battery pack charging.
3. Intelligent Monitoring Circuit: Intelligent Monitoring Module → Real-time collect mains voltage, rectifier module output parameters, energy storage battery power, equipment operating temperature/humidity and other data → Upload data to remote monitoring platform → Automatically alarm in case of abnormal conditions (such as mains interruption, voltage abnormality, insufficient battery power) → Operation and maintenance personnel check and regulate remotely (such as remotely starting diesel generator, remotely switching power supply mode).
4. Protection Circuit: All equipment is integrated with overload, short circuit, overvoltage and undervoltage protection functions; lightning arresters are equipped at the mains access end and AC/DC power distribution screens to prevent equipment damage caused by lightning strikes; the energy storage lithium battery pack is equipped with overcharge and over-discharge protection modules to extend battery service life; the whole system has surge protection and leakage protection functions to ensure the safety of equipment and operation and maintenance personnel.
3.4 Product Technical Parameters
3.4.1 Technical Parameters of Core Power Supply Equipment
| Equipment Name | Core Technical Parameters |
| Mains Access Switch | 1. Input voltage: 380V/220V AC, 50Hz; 2. Rated current: 100A; 3. Protection level: IP65; 4. Protection functions: overload, short circuit, leakage protection; 5. Action time: short circuit protection ≤0.1s, overload protection adjustable; 6. Operating temperature: -30℃~70℃; 7. Service life: ≥10 years. |
| Rectifier Module | 1. Input voltage range: 380V±15% AC, 50Hz±5%; 2. Output voltage: 48V DC (adjustable range 42V~58V); 3. Output current: 50A; 4. Conversion efficiency: ≥95% (under rated load); 5. Ripple voltage: ≤50mV; 6. Power factor: ≥0.98; 7. Protection functions: overvoltage, undervoltage, overcurrent, overtemperature, short circuit protection; 8. Operating temperature: -20℃~60℃; 9. Modular design, supporting hot swapping. |
| Energy Storage Lithium Battery Pack | 1. Cell specification: 3.2V, 200Ah; 2. Combination mode: 16 cells in series, total voltage 51.2V, total capacity 200Ah; 3. Cycle life: ≥2000 times (capacity retention rate ≥80%); 4. Charge and discharge rate: 0.5C charging, 1C discharging; 5. Operating temperature: -20℃~60℃ (discharging), 0℃~55℃ (charging); 6. Protection level: IP67; 7. Protection functions: overcharge, over-discharge, overcurrent, overtemperature, short circuit, balance protection; 8. Weight: ≤150kg; 9. Service life: ≥8 years. |
| DC Power Distribution Screen | 1. Input voltage: 48V DC; 2. Output circuits: 16 circuits, each circuit rated current 10A (expandable to 20 circuits); 3. Total rated current: 63A; 4. Protection functions: overvoltage, undervoltage, overcurrent, short circuit, reverse connection protection; 5. Monitoring function: real-time monitoring of each circuit current and voltage; 6. Protection level: IP54; 7. Operating temperature: -20℃~60℃; 8. Size: 600mm×800mm×2000mm (customizable). |
| AC Power Distribution Screen | 1. Input voltage: 380V/220V AC, 50Hz; 2. Output circuits: 8 circuits, each circuit rated current 16A (expandable to 12 circuits); 3. Total rated current: 63A; 4. Protection functions: overload, short circuit, overvoltage, undervoltage, lightning protection; 5. Monitoring function: real-time monitoring of input voltage, current and frequency; 6. Protection level: IP54; 7. Operating temperature: -20℃~60℃; 8. Size: 600mm×800mm×2000mm (customizable). |
| Intelligent Monitoring Module | 1. Monitoring parameters: voltage (AC/DC), current (AC/DC), temperature, humidity, battery power, equipment operating status; 2. Collection accuracy: voltage ±0.5%, current ±1%, temperature ±0.5℃; 3. Communication mode: supports 4G/5G, Ethernet, RS485 remote communication; 4. Alarm function: automatic pop-up window, SMS and sound-light alarm for abnormal conditions (voltage abnormality, battery undercharge, equipment failure); 5. Control function: remote switching of power supply mode, remote start/stop of backup equipment, remote adjustment of output parameters; 6. Data storage: ≥1 year of historical data, supporting export; 7. Operating temperature: -30℃~70℃; 8. Protection level: IP54. |
3.4.2 Technical Parameters of Optional Equipment
| Equipment Name | Core Technical Parameters |
| Photovoltaic Controller | 1. Input voltage: 48V DC; 2. Rated current: 30A; 3. Maximum Power Point Tracking (MPPT) efficiency: ≥99%; 4. Conversion efficiency: ≥97%; 5. Protection functions: overcharge, over-discharge, overcurrent, overtemperature, reverse connection protection; 6. Operating temperature: -25℃~70℃; 7. Protection level: IP65. |
| Photovoltaic Panel | 1. Power: 550W; 2. Conversion efficiency: ≥23%; 3. Size: 1722mm×1134mm×35mm; 4. Protection level: IP67; 5. Wind resistance level: 12; 6. Hail resistance level: diameter 25mm; 7. Operating temperature: -40℃~85℃; 8. Service life: ≥25 years. |
| Backup Diesel Generator Controller | 1. Input voltage: 24V DC; 2. Control power: 5-10kW; 3. Start mode: dual mode of automatic start and manual start; 4. Start delay: adjustable (0-30s); 5. Protection functions: alarm and shutdown for diesel generator overload, overtemperature, low oil pressure and low oil level; 6. Communication mode: supports RS485, 4G/5G remote communication; 7. Operating temperature: -20℃~60℃; 8. Protection level: IP54. |
| Lightning Arrester | 1. Rated voltage: 380V AC; 2. Discharge current capacity: 20kA (8/20μs); 3. Response time: ≤25ns; 4. Protection level: Class B (primary lightning protection); 5. Operating voltage: adjustable, adapted to mains voltage range; 6. Operating temperature: -40℃~85℃; 7. Protection level: IP65; 8. Service life: ≥5 years. |
3.5 Product Application Scope
This base station power supply solution is suitable for various communication base stations and communication-related scenarios. The core application scope is as follows:
1. Communication Base Stations: 4G/5G macro base stations, micro base stations, distributed base stations, integrated base stations, emergency communication base stations, covering various deployment scenarios such as cities, suburbs, towns, remote mountainous areas and islands, especially suitable for remote base stations with unstable mains power or insufficient mains coverage.
2. Special Scenario Base Stations: Highway along-line base stations, railway along-line base stations, tunnel base stations, mining area base stations, offshore platform base stations. The equipment configuration can be adjusted according to scenario characteristics (such as high temperature, low temperature, humidity, frequent lightning strikes) to ensure stable power supply.
3. Emergency Communication Scenarios: Temporary power supply for emergency base stations when mains power is interrupted due to natural disasters such as earthquakes, floods and typhoons; short-term power supply for temporary base stations in large-scale activities (exhibitions, competitions), which can be quickly deployed to ensure smooth emergency communication.
4. Scenarios Without Mains Power: In areas without mains coverage such as remote mountainous areas, deserts and islands, the combination mode of “photovoltaic + energy storage” or “diesel generator + energy storage” is adopted to provide long-term and stable power supply for base stations, solving the pain points of poor power grid coverage and high power supply costs.
5. Scenarios with High Reliability Requirements: Core urban base stations, key guarantee base stations (such as government affairs communication base stations, medical emergency communication base stations). Through dual power supply and redundant configuration, the power supply reliability is improved to ensure uninterrupted operation of base stations, meeting high availability requirements (above 99.99%).
6. Existing Base Station Transformation: Upgrade and transform the power supply system of existing base stations, replace old power supply equipment, improve power supply stability, energy saving and intelligence level, reduce operation and maintenance costs, and adapt to the power consumption needs of new-generation communication equipment.
3.6 Product Advantages
3.6.1 Stability Advantages
1. Complementarity of Multiple Power Supply Modes: Supports flexible switching of four power supply modes: mains power, photovoltaic power, diesel generator and energy storage. When the mains power is normal, it relies on the mains power for efficient power supply; when the mains power is interrupted, it automatically switches to energy storage or diesel generator power supply, ensuring 24/7 uninterrupted operation of core base station equipment. The power supply availability is ≥99.99%, which effectively solves the problem of low power supply reliability in remote areas.
2. Redundant Design: The rectifier module adopts “3 in use, 1 standby” configuration, and core equipment is equipped with backup circuits to avoid the paralysis of the entire power supply system caused by a single point of failure; the energy storage lithium battery pack supports parallel expansion, and the capacity can be flexibly adjusted according to base station power consumption to ensure emergency power supply duration.
3. Wide Environment Adaptability: All equipment has wide temperature working capacity (-40℃~85℃) and high protection level (IP54 and above), which can adapt to harsh environments such as high temperature, low temperature, humidity, dust and frequent lightning strikes, and is suitable for base stations in various outdoor and remote scenarios.
4. Precise Voltage Control: The output voltage of the rectifier module is stable, and the ripple voltage is ≤50mV, which can effectively protect precision base station equipment, avoid equipment failure and communication interruption caused by voltage fluctuation, and extend the service life of base station equipment.
3.6.2 Energy Saving Advantages
1. High Efficiency Conversion: The conversion efficiency of the rectifier module is ≥95%, the conversion efficiency of the photovoltaic panel is ≥23%, and the MPPT efficiency of the photovoltaic controller is ≥99%, which greatly reduces power conversion loss, improves power utilization rate and reduces energy waste.
2. Intelligent Energy Saving Regulation: The intelligent monitoring module can automatically adjust the power supply mode and output parameters according to base station equipment power consumption, mains voltage and photovoltaic power generation, avoiding invalid power supply; the energy storage lithium battery pack adopts intelligent charge and discharge management to extend battery life and reduce operation and maintenance energy consumption.
3. Green and Environmental Protection: Supports the access of photovoltaic clean energy, reduces fossil energy consumption (such as diesel generator use), reduces carbon emissions, and conforms to the development trend of green communication; the equipment adopts environmentally friendly materials without harmful substances, meeting industry environmental protection standards.
3.6.3 Intelligence Advantages
1. Real-time Monitoring of All Parameters: The intelligent monitoring module can real-time collect all core parameters such as mains voltage, current, energy storage battery power, equipment operating temperature and humidity. The data collection accuracy is high, and the system operation status can be checked and mastered in real time remotely.
2. Intelligent Fault Early Warning and Handling: In case of abnormal conditions (mains interruption, voltage abnormality, battery undercharge, equipment failure), it will automatically alarm (SMS, sound and light, platform pop-up window), and at the same time, it can automatically switch power supply mode and start backup equipment, reducing manual intervention and fault handling time.
3. Remote Operation and Maintenance: Supports 4G/5G and Ethernet remote communication. Operation and maintenance personnel can remotely check system operation data, regulate equipment and troubleshoot faults without on-site duty, which greatly reduces operation and maintenance costs and workload, especially suitable for the operation and maintenance needs of remote base stations.
4. Data-based Management: Historical operation data is stored for ≥1 year, supporting data export and analysis, which can provide data support for base station power supply optimization and operation and maintenance plan formulation, realizing refined operation and maintenance.
3.6.4 Practicality Advantages
1. Modular Design: All equipment adopts modular design, supporting hot swapping and flexible expansion. The equipment configuration can be adjusted according to base station scenarios and power consumption needs (such as adding photovoltaic panels and expanding energy storage batteries), which is suitable for base stations of different scales and scenarios and has strong versatility.
2. Convenient Installation: The equipment has moderate volume and reasonable structure, which can be quickly installed and debugged without large-scale transformation of the base station computer room. It is suitable for the transformation of existing base stations and the deployment of new base stations, shortening the project implementation cycle.
3. Long Service Life: The service life of core equipment is ≥8 years, the service life of photovoltaic panels is ≥25 years, and the service life of lightning arresters is ≥5 years. The equipment failure rate is low, which reduces the frequency of equipment replacement and long-term operation and maintenance costs.
4. Strong Compliance: All equipment complies with relevant industry standards (such as base station power supply standards, lightning protection standards), with high compliance, which can smoothly pass industry acceptance and ensure the compliant implementation of the project.
3.7 Product Bid Control Parameters
(Suitable for bidding scenarios, clarify core bid control indicators, no price information, highlight product advantages and compliance, can be directly used in bidding documents, and strictly match KITOZER brand equipment parameters)
| No. | Bid Control Item | Bid Control Parameter Requirements |
| 1 | Core Parameters of Rectifier Module | 1. Input voltage range: 380V±15% AC, 50Hz±5%; 2. Output voltage: 48V DC (42V~58V adjustable), output current ≥50A; 3. Conversion efficiency: ≥95% under rated load, power factor ≥0.98; 4. Ripple voltage ≤50mV; 5. Supports hot swapping, with overvoltage, undervoltage, overcurrent, overtemperature and short circuit protection functions; 6. Operating temperature: -20℃~60℃; 7. Brand requirement: KITOZER, provide product compliance test report. |
| 2 | Core Parameters of Energy Storage Lithium Battery Pack | 1. Cell specification: 3.2V, 200Ah, combination mode 16 cells in series, total voltage 51.2V, total capacity ≥200Ah; 2. Cycle life: ≥2000 times (capacity retention rate ≥80%); 3. Charge and discharge rate: 0.5C charging, 1C discharging; 4. Operating temperature: -20℃~60℃ (discharging), 0℃~55℃ (charging); 5. Protection level ≥IP67, with overcharge, over-discharge, overcurrent, overtemperature, short circuit and balance protection functions; 6. Service life ≥8 years; 7. Brand requirement: KITOZER, provide product battery safety test report. |
| 3 | Core Parameters of Intelligent Monitoring Module | 1. Monitorable parameters: AC/DC voltage, AC/DC current, temperature, humidity, battery power, equipment operating status; 2. Collection accuracy: voltage ±0.5%, current ±1%, temperature ±0.5℃; 3. Communication mode: supports 4G/5G, Ethernet, RS485 remote communication; 4. Has automatic alarm function (SMS, sound and light, platform pop-up window), supports remote regulation and remote fault troubleshooting; 5. Historical data storage ≥1 year, supporting export; 6. Operating temperature: -30℃~70℃, protection level ≥IP54; 7. Brand requirement: KITOZER, provide product intelligence function test report. |
| 4 | Core Parameters of DC Power Distribution Screen | 1. Input voltage: 48V DC, output circuits ≥16, total rated current ≥63A; 2. Each output circuit current is adjustable, with overvoltage, undervoltage, overcurrent, short circuit and reverse connection protection functions; 3. Can real-time monitor each circuit current and voltage, supporting linkage with intelligent monitoring module; 4. Protection level ≥IP54, operating temperature: -20℃~60℃; 5. Size customizable, supporting modular expansion; 6. Brand requirement: KITOZER, provide product power distribution safety test report. |
| 5 | Core Parameters of AC Power Distribution Screen | 1. Input voltage: 380V/220V AC, 50Hz, output circuits ≥8, total rated current ≥63A; 2. Has overload, short circuit, overvoltage, undervoltage and lightning protection functions; 3. Can real-time monitor input voltage, current and frequency, supporting linkage with intelligent monitoring module; 4. Protection level ≥IP54, operating temperature: -20℃~60℃; 5. Size customizable, supporting modular expansion; 6. Brand requirement: KITOZER, provide product power distribution safety test report. |
| 6 | Overall System Requirements | 1. Supports automatic switching of four power supply modes: mains power, photovoltaic power, diesel generator and energy storage, switching time ≤10ms, ensuring uninterrupted operation of core base station equipment; 2. Power supply availability ≥99.99%; 3. Core equipment adopts modular design, supporting hot swapping and flexible expansion; 4. All equipment protection levels meet the requirements of outdoor scenarios, and can adapt to -40℃~85℃ wide temperature environment; 5. The system has lightning protection, surge protection and leakage protection functions, lightning arrester discharge current capacity ≥20kA, response time ≤25ns; 6. Complies with relevant industry communication base station power supply standards, provide system overall compliance test report; 7. Supports remote operation and maintenance, realizing remote monitoring, remote regulation, fault early warning and data statistical analysis. |
| 7 | Bid Control Parameters of Optional Equipment (Photovoltaic Panel) | 1. Power ≥550W, conversion efficiency ≥23%; 2. Protection level ≥IP67, wind resistance level ≥12, hail resistance level ≥diameter 25mm; 3. Operating temperature: -40℃~85℃, service life ≥25 years; 4. Brand requirement: KITOZER, provide product photovoltaic conversion efficiency test report. |
3.8 Technical Solutions
3.8.1 Core Technical Ideas
With the core goals of “stable power supply, energy saving and high efficiency, intelligent operation and maintenance, and multi-scenario adaptation”, this base station power supply solution relies on four core technologies: “multi-power supply mode complementarity, modular design, intelligent monitoring and regulation, and hierarchical protection” to solve various pain points in the process of base station power supply. It takes into account the deployment of new base stations and the transformation of existing base stations, realizes the efficient operation of the power supply system throughout its life cycle, and at the same time adapts to the development needs of green communication, reducing energy consumption and operation and maintenance costs.
3.8.2 Scenario-based Technical Solutions
Scenario 1: Urban Base Stations with Stable Mains Power (New/Existing)
Core Needs: Ensure stable mains power supply, respond to sudden mains power interruption, improve power supply reliability, reduce operation and maintenance costs, and adapt to the needs of high-density deployment and convenient operation and maintenance of urban base stations.
Technical Solution: 1. Core Configuration: Mains Access Switch + Rectifier Module (3 in use, 1 standby) + Energy Storage Lithium Battery Pack + DC/AC Power Distribution Screen + Intelligent Monitoring Module + Lightning Arrester; 2. Power Supply Mode: Mains power is preferred for power supply, and the rectifier module converts mains AC power into DC power to supply base station equipment and charge the energy storage lithium battery pack; 3. Emergency Handling: When the mains power is interrupted, the intelligent monitoring module detects it automatically and switches to the energy storage lithium battery pack for power supply within 10ms to ensure the uninterrupted operation of core base station equipment (main equipment, transmission equipment). When the mains power is restored, it automatically switches back to mains power supply and supplements the energy storage lithium battery pack with charging; 4. Operation and Maintenance Optimization: The intelligent monitoring