Table of Contents
Toggle1. System Overview
The Intelligent Integrated System for Classified Premises is an all-in-one intelligent management and control platform developed by KITOZER exclusively for high-security classified scenarios including Party and government organs, military industrial enterprises, research institutes, and confidential computer rooms. It deeply integrates the Internet of Things (IoT), national cryptographic encryption, AI intelligent analysis, private network transmission, and digital twin technologies to build a full closed-loop security protection system featuring “Perception – Transmission – Analysis – Control – Traceability”.
Centered on the design concepts of independent controllability, security & confidentiality, intelligent linkage, and full-process traceability, the system strictly complies with the Law of the People’s Republic of China on Guarding State Secrets, Measures for the Administration of Graded Protection of Classified Information Systems, and Level-3 and above Classified Protection of Cybersecurity (Level Protection 2.0) standards. It realizes all-round, all-weather intelligent management and control of personnel, equipment, environments, carriers, and networks within classified areas, eliminating security risks such as illegal intrusion, irregular operations, and information leakage. It delivers highly reliable, customized, traceable comprehensive security solutions for classified premises.
2. System Composition
The system adopts a four-layer architecture: Hardware Perception Layer, Private Network Transmission Layer, Platform Application Layer, and Intelligent Execution Layer. Each layer operates independently while achieving seamless linkage. The core components are as follows:
- Hardware Perception Layer: Responsible for data collection and status perception. It covers terminal equipment of sub-systems including video surveillance, access control, intrusion alarm, environmental monitoring, classified carrier management, network security protection, and intelligent power supply, enabling real-time collection of status data of personnel, assets, and equipment.
- Private Network Transmission Layer: Adopts an architecture of three-network isolation (internal network / external network / equipment network) + national cryptographic encryption + private network transmission. It deploys security isolation gateways, encrypted switches, optical fiber transceivers and other devices to ensure classified data transmission is “unwiretappable, unalterable, and leakage-proof”, eliminating cross-network data leakage risks.
- Platform Application Layer: Equipped with the KITOZER Confidential Intelligent Management & Control Platform running on domestic Kylin OS. It integrates functions including personnel management, permission control, AI video analysis, alarm linkage, data auditing, report generation, and remote operation & maintenance. It supports on-premises and private deployment, with a visualized unified management interface.
- Intelligent Execution Layer: Executes linkage operations upon receiving platform instructions, including intelligent access control gates, automatic turnstiles, audible & visual alarms, environmental regulation equipment, classified storage devices, and emergency response equipment. It enables second-level response, automatic disposal, and full logging for abnormal events.
3. System Classification
3.1 Classification by Security Level
- Basic Type (Level 1) Applicable to general classified office areas and non-core data rooms, meeting basic demands of personnel access control, video surveillance, and temperature & humidity monitoring.
- Enhanced Type (Level 2) Applicable to classified meeting rooms, general confidential computer rooms, and archives warehouses. It adds intrusion alarm, carrier positioning, network isolation, and data auditing functions.
- Fortress Type (Level 3) Applicable to core classified areas, military R&D laboratories, top-secret data rooms, and core confidential computer rooms. It delivers the highest level of security protection with full-stack domestic autonomy, national cryptographic encryption, multi-factor authentication, AI behavior analysis, digital twin, full-process traceability, and emergency linkage.
3.2 Classification by Functional Modules
- Security Control: Access control, perimeter intrusion alarm, intelligent video surveillance, electronic patrol, anti-tailgating interlocking doors
- Classified Carrier Management: RFID classified document management, intelligent confidential cabinets, classified carrier positioning & tracking, destruction equipment control
- Environmental Operation & Maintenance: Temperature & humidity monitoring, water leakage detection, smoke sensing alarm, precision air conditioners, UPS uninterruptible power supply, fire linkage
- Network Security: Security isolation gateways, encrypted switches, firewalls, intrusion detection, log auditing, national cryptographic cipher machines
- Intelligent Linkage: Alarm linkage control, AI behavior recognition, voice control, unattended operation strategies, emergency command & dispatch
4. System Schematic Principle
The KITOZER Confidential Intelligent Management & Control Platform serves as the core of the system. All sub-systems connect to the platform via encrypted private network links: Data collected by perception layer devices (cameras, access controllers, sensors, etc.) → Secure transmission via transmission layer (gateways, encrypted switches) → Unified analysis and processing by platform layer → Linked response by execution layer (access control, alarms, environmental equipment). Local operation and remote O&M are both supported. All operation data is fully recorded and traceable to form closed-loop management and control.
5. Full System Configuration List (Basic / Enhanced / Fortress Grade)
5.1 Basic Type (Low-End) Configuration List
表格
| No. | Product Name | Model & Specification | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Confidential Intelligent Management Platform (Basic Version) | KITOZER-SM-B1 | 1. Domestic Kylin Linux OS; 2. Supports access of up to 100 devices; 3. Basic personnel management, video preview, alarm recording functions; 4. 19-inch standard rack-mounted, 4-core CPU, 8G RAM, 500G HDD | 1 | Set | KITOZER | On-premises deployment for basic management |
| 2 | HD Network Bullet Camera | KITOZER-CAM-B2 | 1. 2MP, 1080P resolution; 2. 30m infrared night vision; 3. H.265 encoding; 4. IP66 protection; 5. 10/100M Ethernet port | 8 | Unit | KITOZER | Covers office areas and corridors |
| 3 | Facial Access Control Terminal (Basic) | KITOZER-ACC-B3 | 1. 2MP facial capture camera; 2. Facial / card authentication supported; 3. Stores 1,000 facial templates; 4. IP54 protection; 5. 12VDC power supply | 4 | Unit | KITOZER | Entrances of offices and meeting rooms |
| 4 | Temperature & Humidity Sensor | KITOZER-ENV-B4 | 1. Measuring range: Temp -10℃~50℃, Humidity 10%~90% RH; 2. Accuracy: ±0.5℃, ±3% RH; 3. RS485 communication; 4. 12VDC power supply | 6 | Unit | KITOZER | Indoor environmental monitoring |
| 5 | Water Leakage Detection Cable | KITOZER-ENV-B5 | 1. 10m sensing length; 2. Detection accuracy ±5cm; 3. Normally open / normally closed output; 4. Waterproof & anti-corrosion; 5. Suitable for computer rooms and archives | 2 | Roll | KITOZER | Water leakage prevention for computer rooms and archives |
| 6 | Network Switch (Basic) | KITOZER-NET-B6 | 1. 8-port 100M, 2-port Gigabit uplink; 2. 4-port PoE (IEEE802.3af); 3. Industrial grade, IP30; 4. 12VDC power supply | 2 | Unit | KITOZER | Terminal device access |
| 7 | UPS Uninterruptible Power Supply (Basic) | KITOZER-UPS-B7 | 1. Rated capacity 1kVA/0.8kW; 2. Online double-conversion, 0ms switching time; 3. 30min full-load backup time; 4. Withstands 125% overload for 10min; 5. 19-inch rack-mounted | 1 | Unit | KITOZER | Ensures core equipment operation during power failure |
| 8 | Audible & Visual Alarm | KITOZER-ALM-B8 | 1. 110dB high decibel; 2. Red warning light; 3. 12VDC power supply; 4. Waterproof, IP65 | 2 | Unit | KITOZER | Alarm prompt |
5.2 Enhanced Type (Mid-End) Configuration List
表格
| No. | Product Name | Model & Specification | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Confidential Intelligent Management Platform (Enhanced Version) | KITOZER-SM-M1 | 1. Domestic Kylin Linux OS; 2. Supports access of up to 500 devices; 3. Personnel permission grading, AI video motion detection, alarm linkage, data auditing, dual-machine hot standby; 4. 19-inch 2U rack-mounted, 8-core CPU, 16G RAM, 1T SSD | 1 | Set | KITOZER | Local + backup deployment for enhanced management |
| 2 | HD Network Camera (Dome + Bullet) | KITOZER-CAM-M2 | 1. 4MP, 2K resolution; 2. 50m infrared night vision + 30m warm light fill; 3. H.265+ encoding for storage reduction; 4. IP66 protection; 5. AI human body detection | 12 | Unit | KITOZER | Dome for indoor, bullet for perimeter |
| 3 | Facial Access Control Terminal (Enhanced) | KITOZER-ACC-M3 | 1. 5MP camera with living body detection; 2. 4-in-1 authentication: Face / Fingerprint / Card / Password; 3. Stores 5,000 faces, 1,000 fingerprints; 4. National cryptographic algorithm encryption; 5. Anti-pry alarm, IP54 protection | 6 | Unit | KITOZER | Entrances of classified meeting rooms and computer rooms |
| 4 | Anti-Tailgating Interlocking Door | KITOZER-ACC-M4 | 1. Stainless steel, anti-violent damage; 2. Dual-door interlock anti-tailgating; 3. Linked with access control, overtime door opening alarm; 4. Remote control support; 5. IP54 protection | 2 | Set | KITOZER | Entrance of core classified areas |
| 5 | Composite Temp-Humidity & Smoke Sensor | KITOZER-ENV-M5 | 1. Temp -20℃~60℃, Humidity 5%~95% RH; 2. Photoelectric smoke sensor with adjustable sensitivity; 3. RS485 + wireless dual communication; 4. Low power alarm, 12VDC supply | 8 | Unit | KITOZER | Environmental & fire monitoring for computer rooms and archives |
| 6 | Vibration Fiber Perimeter Alarm System | KITOZER-SEC-M6 | 1. Max detection distance 500m; 2. Anti-climbing, anti-cutting with precise intrusion positioning; 3. Anti-interference for complex environments; 4. Linked camera snapshot trigger; 5. IP67 protection | 1 | Set | KITOZER | Park perimeter protection |
| 7 | RFID Classified Carrier Management Terminal | KITOZER-DOC-M7 | 1. UHF RFID read-write; 2. Identification distance 0.5-5m; 3. Batch tag reading supported; 4. Stores 100,000 records; 5. 19-inch rack-mounted | 2 | Unit | KITOZER | Management of classified documents and archives |
| 8 | Basic Security Isolation Gateway | KITOZER-NET-M8 | 1. “2+1” architecture, dual-host single isolation; 2. Internal / external network isolation; 3. National cryptographic encrypted data ferry; 4. 100Mbps throughput; 5. 19-inch rack-mounted | 1 | Unit | KITOZER | Isolation between classified internal network and external network |
| 9 | Enhanced Encrypted Switch | KITOZER-NET-M9 | 1. 24-port Gigabit, 4-port 10G uplink; 2. SM4 national cryptographic encryption; 3. VLAN division, port isolation; 4. Industrial grade, IP40, redundant power supply | 2 | Unit | KITOZER | Encrypted transmission of classified internal network data |
| 10 | UPS Uninterruptible Power Supply (Enhanced) | KITOZER-UPS-M10 | 1. Rated capacity 10kVA/9kW; 2. Online double-conversion, 0ms switching; 3. 60min full-load backup time; 4. N+1 redundancy support; 5. 19-inch rack-mounted with LCD touch screen | 1 | Unit | KITOZER | Long-term power supply for core computer room equipment |
| 11 | Intelligent Confidential Cabinet | KITOZER-DOC-M11 | 1. Steel cabinet, anti-pry & anti-drill; 2. Triple authentication: Fingerprint / Password / Mechanical lock; 3. Built-in temperature & humidity monitoring; 4. Unalterable door opening records; 5. Size: 1800×900×450mm | 4 | Unit | KITOZER | Storage of classified documents and materials |
5.3 Fortress Type (High-End) Configuration List
表格
| No. | Product Name | Model & Specification | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Confidential Intelligent Management Platform (Fortress Version) | KITOZER-SM-H1 | 1. Domestic Kylin Linux OS, full-stack independent controllability; 2. Supports access of up to 2,000 devices; 3. AI behavior analysis (smoking / unauthorized photography / illegal intrusion recognition), digital twin visualization, multi-level permission control, full-data auditing, emergency command dispatch; 4. 19-inch 4U rack-mounted, dual 8-core CPU, 32G RAM, 2T SSD + 4T HDD; 5. Dual hot standby + off-site backup, 99.999% availability | 1 | Set | KITOZER | Highest security grade full-function management |
| 2 | Full-Function AI Intelligent Camera | KITOZER-CAM-H2 | 1. 8MP, 4K resolution; 2. Infrared + laser night vision up to 150m; 3. AI analysis: Face capture, behavior recognition, area intrusion, cross-border detection; 4. H.265+ encoding, edge computing; 5. IP67 protection, explosion-proof Exd II BT4; 6. National cryptographic encrypted transmission | 16 | Unit | KITOZER | Core classified areas, perimeter, key passages |
| 3 | Multi-Factor Authentication Access Control Terminal (Fortress) | KITOZER-ACC-H3 | 1. 5MP 3D binocular camera with 3D living body detection; 2. 5-in-1 authentication: Face / Fingerprint / Iris / Card / Password; 3. SM2/SM3/SM4 national cryptographic algorithms; 4. Stores 10,000 faces, 5,000 fingerprints; 5. Anti-pry, anti-dismantling, anti-coercion alarm; 6. IP65 protection, military-grade quality | 8 | Unit | KITOZER | Entrances of top-secret areas and core computer rooms |
| 4 | High-Security Anti-Tailgating Interlocking Door (Fortress) | KITOZER-ACC-H4 | 1. Bulletproof steel plate, anti-violent destruction; 2. Dual-door interlock + triple sensor detection for anti-tailgating & anti-coercion; 3. Linked with AI camera snapshot and platform alarm; 4. Remote authorization & emergency unlock support; 5. IP65, explosion-proof design | 3 | Set | KITOZER | Main entrances of core classified areas |
| 5 | Multi-Parameter Environmental Monitoring Terminal | KITOZER-ENV-H5 | 1. Temp -40℃~85℃, Humidity 0%~100% RH; 2. Integrated sensors: Temp, humidity, smoke, water leakage, formaldehyde, PM2.5, differential pressure; 3. Wired + wireless + fiber triple communication; 4. National cryptographic encrypted transmission; 5. 12/24V wide voltage industrial grade | 12 | Unit | KITOZER | Precision computer rooms and classified laboratories |
| 6 | Combined Perimeter System: Pulse Electronic Fence + Vibration Fiber | KITOZER-SEC-H6 | 1. Pulse electronic fence: Anti-high voltage strike, anti-climbing, max length 1,000m; 2. Vibration fiber: Precise positioning, anti-cutting & anti-crossing; 3. Dual-system linkage, 99.9% alarm accuracy; 4. Linked with AI cameras, audible & visual alarms, platform pop-up alerts; 5. IP67 protection for extreme weather | 1 | Set | KITOZER | High-security perimeter of the whole park |
| 7 | RFID Full Lifecycle Management System for Classified Carriers | KITOZER-DOC-H7 | 1. UHF RFID, identification distance 0.5-10m; 2. Full-process management: Tag binding, positioning, tracking, inventory, destruction for documents / equipment / supplies; 3. Tamper-proof & anti-counterfeit tags; 4. Encrypted data storage with full traceability; 5. Batch import & export, automatic report generation | 1 | Set | KITOZER | Control of classified documents, equipment and supplies |
| 8 | Fortress-Grade Security Isolation Gateway | KITOZER-NET-H8 | 1. Dedicated chip “2+1” architecture for physical isolation; 2. Triple network isolation: Classified internal / non-classified / external network; 3. National cryptographic encryption + virus scanning + content filtering; 4. 1000Mbps throughput, zero-delay data ferry; 5. 19-inch 4U rack-mounted, redundant power supply, dual hot standby | 2 | Unit | KITOZER | Triple network physical isolation to prevent cross-network leakage |
| 9 | Fortress-Grade National Cryptographic Encrypted Switch | KITOZER-NET-H9 | 1. 48-port Gigabit, 8-port 10G uplink; 2. Dual encryption: SM4 + AES national cryptographic algorithms; 3. Port isolation, MAC binding, anti-attack protection; 4. Industrial grade IP54, redundant power supply; 5. IPv6 support, domestic chips | 4 | Unit | KITOZER | Core encrypted transmission of classified internal network |
| 10 | Intrusion Detection System (IDS) | KITOZER-NET-H10 | 1. Gigabit traffic monitoring support; 2. Real-time detection of network attacks, abnormal access, data leakage; 3. National cryptographic encryption, full log recording; 4. Linked with firewalls to block attacks; 5. 19-inch rack-mounted, domestic OS | 1 | Set | KITOZER | Security protection for classified internal network |
| 11 | National Cryptographic Cipher Machine | KITOZER-NET-H11 | 1. Certified by State Cryptography Administration; 2. Supports SM1/SM2/SM3/SM4 national cryptographic algorithms; 3. End-to-end encryption for classified data, voice and video; 4. 19-inch 2U rack-mounted, redundant power supply, dual hot standby | 1 | Set | KITOZER | Full-link national cryptographic encryption |
| 12 | UPS Uninterruptible Power Supply (Fortress) | KITOZER-UPS-H12 | 1. Rated capacity 200kVA/180kW; 2. Online double-conversion modular architecture; 3. 120min full-load backup time; 4. N+1/2N redundancy, up to 6 units parallel; 5. Efficiency ≥96%, large LCD touch screen; 6. IP31 protection, wide temperature operation | 1 | Unit | KITOZER | Long-term stable power supply for core computer rooms |
| 13 | Intelligent Constant Temperature & Humidity Precision Air Conditioner | KITOZER-ENV-H13 | 1. Cooling capacity 12.5kW; 2. Temp control range 18℃-28℃, accuracy ±0.5℃; 3. Humidity control range 40%-60% RH, accuracy ±3% RH; 4. Industrial grade 24/7 operation; 5. Remote monitoring & fault alarm support | 2 | Unit | KITOZER | Precision classified computer rooms and laboratories |
| 14 | High-Security Intelligent Confidential Cabinet (Fortress) | KITOZER-DOC-H14 | 1. Military-grade bulletproof steel plate, anti-pry, anti-drill & anti-destruction; 2. Quadruple authentication: Fingerprint / Password / Iris / Mechanical lock; 3. Built-in constant temperature & humidity, anti-magnetic, moisture-proof, fire-proof; 4. Unalterable full records of opening, closing and authorization; 5. Size: 2000×1000×500mm, customizable | 6 | Unit | KITOZER | Storage of top-secret documents and core materials |
| 15 | Digital Twin Visual Large Screen | KITOZER-DIS-H15 | 1. 55-inch 4K LED splicing screen; 2. 3D modeling of classified premises with real-time data mapping; 3. Displays personnel location, equipment status, environmental parameters and alarm information; 4. Touch interaction & remote control support; 5. Industrial grade 7×24h operation | 1 | Set | KITOZER | Visual management & control of command center |
6. Full Product Technical Parameters
6.1 Confidential Intelligent Management Platform Series
- KITOZER-SM-B1 (Basic Version) Domestic Kylin Linux OS; 4-core CPU, 8G DDR4 RAM, 500G SATA HDD; 2×10/100/1000M adaptive Ethernet ports; supports up to 100 connected devices; basic personnel management, video preview, alarm recording and report export functions; 19-inch 1U rack-mounted; operating temperature 0℃-50℃, humidity 10%-90% RH (non-condensing).
- KITOZER-SM-M1 (Enhanced Version) Domestic Kylin Linux OS; 8-core CPU, 16G DDR4 RAM, 1T SSD; 4×10/100/1000M adaptive Ethernet ports; supports up to 500 connected devices; personnel permission grading, AI video motion detection, alarm linkage, data auditing, dual-machine hot standby; 19-inch 2U rack-mounted; operating temperature -10℃-55℃, humidity 5%-95% RH (non-condensing).
- KITOZER-SM-H1 (Fortress Version) Full-stack domestically controlled Kylin Linux OS; dual 8-core CPU, 32G DDR4 RAM, 2T SSD + 4T HDD; 6×10/100/1000M/10G adaptive Ethernet ports; supports up to 2,000 connected devices; AI behavior analysis, digital twin visualization, multi-level permission control, full-data auditing, emergency command dispatch, dual hot standby + off-site backup; 19-inch 4U rack-mounted; operating temperature -20℃-60℃, humidity 0%-100% RH (non-condensing); availability ≥99.999%.
6.2 HD Network Camera Series
- KITOZER-CAM-B2 (Basic Bullet Camera) 2MP (1920×1080); 1/2.7″ CMOS image sensor; 30m 850nm infrared night vision with 4 infrared lamps; H.265 encoding, Onvif protocol compatible; 10/100M Ethernet port; IP66 protection; DC12V±5% power supply; operating temperature -30℃-60℃.
- KITOZER-CAM-M2 (Enhanced Dome / Bullet Camera) 4MP (2560×1440); 1/1.7″ CMOS image sensor; 50m infrared night vision + 30m warm light fill; H.265+ encoding for storage reduction; AI human body detection & area intrusion; 10/100M Ethernet port; IP66 protection; DC12V / PoE power supply; operating temperature -35℃-65℃.
- KITOZER-CAM-H2 (Fortress AI Camera) 8MP (3840×2160); 1/1.2″ starlight CMOS image sensor; 150m laser infrared night vision with 6×850nm infrared lamps + 50m warm light fill; H.265+ encoding, edge computing supported; AI face capture, behavior recognition (smoking / unauthorized photography / illegal intrusion), cross-border detection; SM4 national cryptographic encrypted transmission; 10/100/1000M Ethernet port; IP67 protection, explosion-proof Exd II BT4; DC12V / PoE power supply; operating temperature -40℃-70℃.
6.3 Facial Access Control Terminal Series
- KITOZER-ACC-B3 (Basic) 2MP binocular camera; facial recognition distance 0.3-2m; facial / card authentication supported; stores 1,000 facial templates, 500 cards; recognition speed ≤0.8s; IP54 protection; Wiegand 26/34 signal output; DC12V±5% power supply; operating temperature -10℃-50℃.
- KITOZER-ACC-M3 (Enhanced) 5MP binocular camera with living body detection; 4-in-1 authentication: Face / Fingerprint / Card / Password; stores 5,000 faces, 1,000 fingerprints, 1,000 cards; recognition speed ≤0.5s; SM3 national cryptographic encryption; anti-pry & anti-dismantling alarm; IP54 protection; Wiegand / RS485 communication; DC12V power supply; operating temperature -15℃-55℃.
- KITOZER-ACC-H3 (Fortress) 5MP 3D binocular camera with 3D living body detection; 5-in-1 authentication: Face / Fingerprint / Iris / Card / Password; stores 10,000 faces, 5,000 fingerprints, 2,000 cards; recognition speed ≤0.3s; SM2/SM3/SM4 national cryptographic algorithms; anti-pry, anti-dismantling & anti-coercion alarm; IP65 military-grade protection; encrypted TCP/IP / RS485 communication; DC12/24V wide voltage power supply; operating temperature -20℃-60℃.
6.4 Environmental Monitoring Series
- KITOZER-ENV-B4 (Temperature & Humidity Sensor) Temp range -10℃~50℃, accuracy ±0.5℃; Humidity range 10%~90% RH, accuracy ±3% RH; RS485 Modbus communication; DC12V power supply; power consumption ≤1W; IP30 protection; operating temperature -10℃-50℃.
- KITOZER-ENV-M5 (Composite Temp-Humidity & Smoke Sensor) Temp range -20℃~60℃, accuracy ±0.3℃; Humidity range 5%~95% RH, accuracy ±2% RH; photoelectric smoke sensor with adjustable sensitivity (0.15-0.3dB/m); RS485 + 433MHz wireless dual communication; DC12V power supply, low battery alarm; IP40 protection; operating temperature -15℃-55℃.
- KITOZER-ENV-H5 (Multi-Parameter Environmental Monitoring Terminal) Temp range -40℃~85℃, accuracy ±0.2℃; Humidity range 0%~100% RH, accuracy ±1.5% RH; integrated sensors: Temp, humidity, smoke, water leakage, formaldehyde (0-10mg/m³), PM2.5 (0-1000μg/m³), differential pressure (0-1000Pa); wired RS485 + wireless 4G/5G + fiber triple communication; national cryptographic encrypted transmission; DC12/24V wide voltage power supply; power consumption ≤3W; IP54 industrial grade; operating temperature -30℃-70℃.
6.5 Network Security Series
- KITOZER-NET-B6 (Basic Switch) 8-port 100M RJ45, 2-port Gigabit uplink; 4-port PoE (IEEE802.3af, 15.4W per port); switching capacity 10Gbps; VLAN division, port isolation; industrial grade IP30; DC12V power supply; operating temperature -10℃-50℃.
- KITOZER-NET-M8 (Basic Isolation Gateway) “2+1” dual-host single isolation architecture; physical isolation between internal & external networks; 100Mbps throughput; supports file ferry & database synchronization; SM4 national cryptographic encryption; 19-inch 2U rack-mounted, redundant power supply; operating temperature 0℃-50℃.
- KITOZER-NET-H8 (Fortress Isolation Gateway) Dedicated chip “2+1” physical isolation architecture; triple network isolation: Classified internal / non-classified / external network; 1000Mbps throughput; national cryptographic encryption + virus scanning + content filtering; real-time data ferry & cross-network file exchange; 19-inch 4U rack-mounted, redundant power supply, dual hot standby; operating temperature -10℃-55℃.
- KITOZER-NET-H11 (National Cryptographic Cipher Machine) Certified by State Cryptography Administration; supports SM1/SM2/SM3/SM4 national cryptographic algorithms; end-to-end encryption for data, voice and video; encryption rate ≥1Gbps; 19-inch 2U rack-mounted, redundant power supply, dual hot standby; operating temperature -15℃-55℃.
6.6 UPS Uninterruptible Power Supply Series
- KITOZER-UPS-B7 (Basic) Rated capacity 1kVA/0.8kW; online double-conversion; input voltage 160-275VAC, frequency 50/60Hz±5%; output voltage 220VAC±1%, frequency 50/60Hz±0.1%; 0ms switching time; 30min full-load backup time; withstands 125% overload for 10min; 19-inch 1U rack-mounted; operating temperature 0℃-40℃.
- KITOZER-UPS-M10 (Enhanced) Rated capacity 10kVA/9kW; online double-conversion; three-phase input 304-456VAC, frequency 50/60Hz±3%; three-phase output 380VAC±0.5%, frequency 50/60Hz±0.01%; 0ms switching time; 60min full-load backup time; withstands 150% overload for 30s; N+1 redundancy support; 19-inch 3U rack-mounted with LCD touch screen; operating temperature 0℃-45℃.
- KITOZER-UPS-H12 (Fortress) Rated capacity 200kVA/180kW; online double-conversion modular architecture; three-phase input 380V±15%, frequency 50/60Hz±3%, power factor ≥0.99; three-phase output 380V±0.5%, frequency 50/60Hz±0.01%, THDv≤1%; 0ms switching time; 120min full-load backup time; withstands 125% overload for 10min, 150% overload for 30s; N+1/2N redundancy, up to 6 units parallel; efficiency ≥96%; large LCD touch screen; IP31 protection; operating temperature 0℃-50℃.
7. Full Product Application Scope
7.1 Confidential Intelligent Management Platform
- Basic Version: General classified office areas, non-core data rooms, small classified meeting rooms, meeting basic personnel & equipment management demands.
- Enhanced Version: Classified meeting rooms, general confidential computer rooms, archives warehouses, R&D laboratories, adapting to linkage management and data auditing demands of medium-security classified scenarios.
- Fortress Version: Core classified areas, military R&D laboratories, top-secret data rooms, core confidential computer rooms, confidential command centers of Party and government organs, covering full-function management demands of highest-security classified scenarios.
7.2 HD Network Camera
- Basic Bullet Camera: Corridors of classified offices, general entrances, non-core areas, for basic video monitoring and recording.
- Enhanced Dome / Bullet Camera: Classified meeting rooms, computer room entrances, archives warehouses, park passages, for human body detection and abnormal behavior early warning.
- Fortress AI Camera: Core classified areas, perimeter walls, key passages, top-secret data rooms, for AI behavior recognition, face capture and intrusion alarm, high-security monitoring.
7.3 Facial Access Control Terminal
- Basic Model: General classified offices, non-core meeting rooms, basic personnel access control.
- Enhanced Model: Classified meeting rooms, general confidential computer rooms, archives warehouses, multi-factor authentication and anti-pry alarm.
- Fortress Model: Core classified areas, top-secret data rooms, military laboratories, core computer rooms, 5-in-1 authentication, living body detection, anti-coercion alarm, highest-security access control.
7.4 Environmental Monitoring Equipment
- Basic Temperature & Humidity Sensor: Classified offices, general warehouses, real-time temperature & humidity monitoring.
- Composite Sensor: Confidential computer rooms, archives warehouses, R&D laboratories, dual monitoring of temperature & humidity + smoke sensing to prevent fire risks.
- Multi-Parameter Terminal: Precision confidential computer rooms, military laboratories, constant temperature & humidity warehouses, synchronous monitoring of multiple environmental parameters to stabilize storage environment of classified equipment and documents.
7.5 Network Security Equipment
- Basic Switch: Terminal access of classified office areas, basic network data transmission.
- Security Isolation Gateway: Isolation between classified internal network and external network to prevent cross-network data leakage.
- National Cryptographic Cipher Machine: Encryption of classified data, voice and video transmission to guarantee full-link data security.
- Intrusion Detection System: Real-time monitoring of classified internal network to defend against network attacks and abnormal access.
7.6 UPS Uninterruptible Power Supply
- Basic Model: Small classified offices, single monitoring equipment, short-duration power failure backup.
- Enhanced Model: General confidential computer rooms, multiple network equipment, medium-duration power backup and redundancy guarantee.
- Fortress Model: Core confidential computer rooms, command centers, precision laboratories, long-term stable power supply and parallel redundancy to ensure 24/7 operation of core equipment.
7.7 Classified Carrier Management Equipment
- RFID Management Terminal: General archives warehouses, temporary storage areas of classified documents, basic document positioning and inventory.
- Intelligent Confidential Cabinet: Classified offices, general warehouses, secure storage of classified documents with access records.
- Full Lifecycle Management System: Core archives, military R&D departments, confidential offices of Party and government organs, full-process management and traceability of classified documents, equipment and supplies.
8. Full Product Advantages
8.1 Core Common Advantages
- Independent Controllability & Confidential Security All series adopt domestic chips and domestic operating systems with full independent controllability and no backdoor risks. Strictly compliant with confidentiality regulations, certified by national cryptography and confidentiality authorities, fully matching security demands of classified scenarios.
- Customized Design with Strong Adaptability Supports customization of hardware, software, functions and appearance. Exclusive solutions can be tailored according to the scale, security level and scenario demands of classified premises, compatible with various architectures and equipment.
- Full-Series Coverage & One-Stop Procurement KITOZER provides full-range classified intelligent products covering perception, transmission, platform and execution layers for one-stop procurement. Strong compatibility and unified after-sales service reduce integration costs.
- Confidential-Grade Quality & High Stability Manufactured with military-grade craftsmanship and strict quality inspection, supporting 24/7 stable operation under high/low temperature, humid, dusty and other complex environments to meet high-reliability demands of classified premises.
- Spot Supply & Fast Delivery Core products are in stock for direct delivery to shorten lead time. OEM & ODM customization available for bulk procurement and project customization.
- Full-Process Traceability & Accountability All equipment operation data and running logs are fully recorded, unalterable and traceable to meet auditing and accountability demands of classified premises.
8.2 Exclusive Advantages of Each Product Series
(1) Confidential Intelligent Management Platform
- Domestic Kylin OS with no backdoors and anti-intrusion performance, complying with graded protection standards of classified information systems.
- Multi-level permission control with separated authorities for administrators, operators and auditors to eliminate unauthorized operations.
- Powerful AI analysis to identify prohibited behaviors in classified scenarios such as smoking, unauthorized photography and illegal intrusion with real-time alarms.
- Digital twin visualization with 3D modeling mapping real-time data to intuitively grasp the overall status of classified premises.
(2) HD Network Camera
- Starlight ultra-high-definition image quality, infrared + laser night vision for clear all-day monitoring without blind spots.
- Edge AI computing completes local intelligent analysis to reduce platform pressure and accelerate alarm response.
- National cryptographic SM4 encrypted transmission prevents video data tampering and theft to guarantee monitoring data security.
- Explosion-proof, waterproof and dustproof design adapting to complex outdoor, perimeter and industrial environments.
(3) Facial Access Control Terminal
- 3D living body detection resists forgery via photos, videos and masks to eliminate identity impersonation.
- Flexible combination of multi-factor authentication (Face / Fingerprint / Iris / Card / Password) matching different security levels.
- Anti-pry, anti-dismantling and anti-coercion alarms with real-time platform reporting to boost entrance security.
- National cryptographic algorithm encryption prevents leakage and tampering of authentication data to protect identity information security.
(4) Environmental Monitoring Equipment
- Multi-parameter integration, one device monitors temperature, humidity, smoke, water leakage and other indicators to lower deployment costs.
- Triple communication redundancy (wired + wireless + fiber) ensures continuous data transmission even during network outages.
- Industrial-grade sensors with high measurement accuracy, strong stability and long service life for long-term uninterrupted monitoring.
(5) Network Security Equipment
- Security isolation gateway adopts physical isolation + data ferry technology to completely cut cross-network connections and prevent data leakage.
- National cryptographic cipher machine certified by State Cryptography Administration encrypts full links with national cryptographic algorithms to guarantee data security.
- Encrypted switches support port isolation, MAC binding and anti-attack functions to build secure transmission channels for classified internal networks.
(6) UPS Uninterruptible Power Supply
- Online double-conversion architecture with 0ms switching for seamless power transition during blackouts to avoid equipment shutdown.
- Modular design supports N+1/2N parallel redundancy and expandable capacity to improve power supply reliability.
- Wide input voltage adapts to grid fluctuations for stable operation under complex power supply environments.
(7) Classified Carrier Management Equipment
- Tamper-proof RFID tags with anti-copy and anti-forgery features bind unique identities to classified carriers to eliminate replacement risks.
- Full lifecycle management covers warehousing, borrowing, usage, return and destruction with traceable records of every link.
- Intelligent confidential cabinets integrate anti-pry, anti-drill, fire-proof, moisture-proof and anti-magnetic functions for all-round protection of classified documents.
9. Bid-Winning Core Parameters (Marked with ★)
9.1 Confidential Intelligent Management Platform
- ★ Adopts domestic Kylin Linux OS with full-stack independent controllability and zero backdoor risks.
- ★ Supports access of no less than 2,000 devices (Fortress Version) for large-scale management capacity.
- ★ Built-in AI behavior analysis to identify prohibited behaviors including smoking, unauthorized photography and illegal intrusion in classified scenarios.
- ★ Supports dual hot standby + off-site backup with system availability ≥99.999%.
- ★ Equipped with digital twin visualization module supporting 3D modeling of classified premises and real-time data mapping.
9.2 HD Network Camera
- ★ 8MP 4K resolution (Fortress Model) with starlight image sensor for clear imaging day and night.
- ★ Infrared + laser night vision distance ≥150m with non-glow light for high concealment.
- ★ Supports edge AI computing to complete local face capture, behavior recognition and intrusion detection.
- ★ Adopts SM4 national cryptographic algorithm to prevent video transmission data tampering and theft.
- ★ IP67 protection grade and explosion-proof rating Exd II BT4 for complex harsh environments.
9.3 Facial Access Control Terminal
- ★ Equipped with 3D living body detection technology to resist forgery via photos, videos and masks.
- ★ Supports 5-in-1 authentication: Face / Fingerprint / Iris / Card / Password (Fortress Model).
- ★ Adopts SM2/SM3/SM4 national cryptographic algorithms for encrypted storage and transmission of authentication data.
- ★ Built-in anti-pry, anti-dismantling and anti-coercion alarm functions with real-time abnormal reporting.
- ★ Facial template storage capacity ≥10,000 (Fortress Model) to meet large-scale personnel management demands.
9.4 Environmental Monitoring Equipment
- ★ Integrates six-parameter monitoring: Temperature, humidity, smoke, water leakage, formaldehyde and PM2.5, differential pressure (Fortress Model).
- ★ Supports triple communication redundancy: Wired + Wireless + Fiber to guarantee continuous data transmission.
- ★ Temperature measurement accuracy ±0.2℃, humidity measurement accuracy ±1.5%RH (Fortress Model).
- ★ Adopts national cryptographic encrypted transmission to prevent monitoring data tampering and theft.
9.5 Network Security Equipment
- ★ Security isolation gateway adopts dedicated chip “2+1” physical isolation architecture to completely cut cross-network connections.
- ★ National cryptographic cipher machine certified by State Cryptography Administration supporting SM1/SM2/SM3/SM4 national cryptographic algorithms.
- ★ Encrypted switch supports dual encryption of SM4 + AES to guarantee secure transmission of internal network data.
- ★ Intrusion detection system supports real-time Gigabit traffic monitoring to block network attacks and abnormal access.
9.6 UPS Uninterruptible Power Supply
- ★ Online double-conversion architecture with 0ms switching time for seamless power transition during blackouts.
- ★ Supports N+1/2N parallel redundancy with maximum 6 parallel units for expandable capacity.
- ★ Rated capacity 200kVA/180kW (Fortress Model) with efficiency ≥96%.
- ★ Full-load backup time ≥120 minutes (Fortress Model) for long-duration power guarantee.
9.7 Classified Carrier Management Equipment
- ★ Adopts UHF RFID tamper-proof tags with anti-copy and anti-forgery features for unique identity binding.
- ★ Supports full lifecycle traceability of classified carriers covering warehousing, borrowing, usage, return and destruction.
- ★ Intelligent confidential cabinet integrates five protections: Fire-proof, moisture-proof, anti-magnetic, anti-pry and anti-drill.
10. Full Product Targeted Solutions
10.1 Solution for Classified Office Areas of Party and Government Organs
For general classified offices, meeting rooms and data rooms of Party and government organs, a combined configuration of Basic + Enhanced Type is adopted: deploy Basic Version management platform, 4MP AI cameras, 4-factor authentication access terminals, composite temperature-humidity & smoke sensors, basic isolation gateways & encrypted switches, 10kVA UPS and intelligent confidential cabinets. It realizes personnel access control, full video coverage, environmental real-time monitoring, secure storage of classified documents and internal network isolation to guarantee daily office security and eliminate basic security risks.
10.2 Solution for Core Classified Areas of Military & R&D Institutions
For military R&D laboratories, top-secret data rooms and core confidential computer rooms, full Fortress Type configuration is adopted: deploy Fortress Version management platform (digital twin + AI behavior analysis), 8MP AI explosion-proof cameras, 5-factor authentication access terminals + anti-tailgating interlocking doors, multi-parameter environmental monitoring terminals, combined perimeter system of pulse electronic fence + vibration fiber, triple-network isolation gateways, encrypted switches + national cryptographic cipher machine, 200kVA UPS, constant temperature & humidity precision air conditioners, full lifecycle carrier management system and digital twin large screen. It builds the highest-level security protection system to realize full-dimensional control of personnel, equipment, environment, carriers and networks and eliminate information leakage and safety accidents.
10.3 Solution for Confidential Computer Rooms & Data Centers
For confidential computer rooms and data server rooms, the core demands focus on stable power supply, compliant environment, network security and video monitoring: deploy Fortress-grade redundant parallel UPS, constant temperature & humidity precision air conditioners, multi-parameter environmental monitoring terminals, 4K AI cameras, national cryptographic encrypted switches, intrusion detection system and water leakage detection cables. It ensures compliant temperature, humidity, differential pressure and cleanliness of computer rooms, zero power interruption, network attack prevention, real-time monitoring of equipment status and secure data storage & transmission.
10.4 Solution for Classified Archives Warehouses
For classified archives warehouses and data rooms, core demands focus on carrier security, suitable storage environment, access control and full traceability: deploy Enhanced Version management platform, AI cameras, facial access terminals, composite temperature-humidity & smoke & water leakage sensors, RFID carrier management system, intelligent confidential cabinets and basic isolation gateways. It realizes full registration, positioning tracking and automatic inventory of archives, environmental monitoring and full video coverage to guarantee secure and traceable storage of classified archives.
10.5 High-Security Perimeter Protection Solution for Classified Parks
For outer walls and entrances of classified institution parks, build a system integrating perimeter intrusion early warning + video linkage + emergency disposal: deploy combined pulse electronic fence + vibration fiber perimeter, 8MP laser night vision AI cameras, audible & visual alarms and anti-tailgating interlocking doors, matched with Enhanced Version management platform. It realizes precise positioning of perimeter intrusions, real-time alarms, automatic camera snapshot and platform pop-up alerts for rapid disposal of illegal external intrusion.
11. Full Product Application Cases
11.1 Classified Office Project of a Provincial Party and Government Organ
- Project Overview: Construction area 5,000㎡, including 20 classified offices, 5 classified meeting rooms and 2 data rooms, Security Level 2.
- Configuration Plan: KITOZER Enhanced Version management platform, 16×4MP cameras, 8×4-factor access terminals, 10×composite sensors, 1×basic isolation gateway, 1×10kVA UPS, 6×intelligent confidential cabinets.
- Project Outcome: Realized graded personnel control, full video coverage and real-time environmental monitoring, secure storage of classified documents. The system has run stably for 3 years with zero safety incidents and passed confidentiality acceptance inspection.
11.2 Core R&D Laboratory Project of a Military Enterprise
- Project Overview: Construction area 2,000㎡, including 3 top-secret R&D laboratories, 1 core data room and 1 confidential computer room, Security Level 3 (Fortress Grade).
- Configuration Plan: KITOZER Fortress Version management platform, 12×8MP AI explosion-proof cameras, 6×5-factor access terminals, 2×anti-tailgating interlocking doors, 8×multi-parameter sensors, 1×combined perimeter system, 2×triple-network isolation gateways, 1×national cryptographic cipher machine, 1×200kVA UPS, 2×precision air conditioners, 1×carrier management system, 1×digital twin large screen.
- Project Outcome: Built a full-dimensional high-security protection system. AI identifies about 12 irregular behaviors annually with 99.9% perimeter intrusion alarm accuracy, full traceability of classified documents, and passed Grade 1 Military Confidentiality Certification.
11.3 Confidential Computer Room Project of a Scientific Research Institute
- Project Overview: Construction area 800㎡, core confidential computer room equipped with 50 servers and 10 storage devices, Security Level 3.
- Configuration Plan: KITOZER Fortress-grade UPS, 2×precision air conditioners, 6×multi-parameter sensors, 8×4K AI cameras, 4×national cryptographic encrypted switches, 1×intrusion detection system, 4×water leakage detection cables.
- Project Outcome: Computer room temperature stabilized at 22℃±0.5℃, humidity at 50% RH±3%, zero power interruption, zero network attack incidents, stable equipment operation, and passed Level-3 Classified Protection of Cybersecurity acceptance inspection.
11.4 Classified Archives Warehouse Project of a Municipal Confidentiality Bureau
- Project Overview: Construction area 1,500㎡, 5 classified archives warehouses storing over 100,000 classified files, Security Level 2.
- Configuration Plan: KITOZER Enhanced Version management platform, 10×AI cameras, 6×facial access terminals, 8×composite sensors, 1×RFID carrier management system, 8×intelligent confidential cabinets, 1×basic isolation gateway.
- Project Outcome: Full registration, positioning tracking and automatic inventory of archives, inventory efficiency improved by 80%, zero file loss or leakage incidents, passed confidentiality acceptance inspection.
12. Common Product Failures & Maintenance
12.1 Confidential Intelligent Management Platform
Common Failures
- Platform fails to boot: Power failure, hard disk damage, system crash. Troubleshooting: Check power connection, replace hard disk, reinstall domestic OS.
- Device access failure: Network disconnection, IP conflict, insufficient permissions. Troubleshooting: Inspect network cables, modify IP addresses, reconfigure device access permissions.
- Abnormal AI analysis: Damaged algorithm module, insufficient computing power. Troubleshooting: Restart platform, upgrade algorithm firmware, expand CPU/RAM capacity.
- Data loss: Hard disk failure, no backup. Troubleshooting: Replace hard disk, restore backup data, configure dual hot standby.
Maintenance Schedule
- Daily: Check platform operating status, CPU/RAM usage, hard disk storage space, review alarm logs.
- Weekly: Reboot platform once, clear system cache, inspect network stability.
- Monthly: Back up system configuration and data, upgrade firmware & algorithms, inspect server hardware (fans, power supply).
- Annual: Replace server hard disks as required, test hardware performance, optimize system configuration.
12.2 HD Network Camera
Common Failures
- No image: Power failure, broken network cable, incorrect IP. Troubleshooting: Inspect power, replace cables, reset IP.
- Blurry / color-distorted image: Dirty lens, faulty infrared lamp, abnormal white balance. Troubleshooting: Wipe lens, replace infrared lamp, calibrate white balance.
- Poor night vision: Damaged infrared lamp, lens obstruction, insufficient power supply. Troubleshooting: Replace infrared lamp, clean lens, check power supply.
- Frequent offline: Unstable network, faulty equipment, overheating. Troubleshooting: Optimize network, repair equipment, improve heat dissipation.
Maintenance Schedule
- Daily: Check camera online status, image clarity and night vision effect.
- Weekly: Wipe lens surface with dust-free cloth, inspect waterproof connector tightness.
- Monthly: Reboot camera, upgrade firmware, inspect aging network cables and power adapters.
- Annual: Test infrared lamp brightness, replace aging accessories, calibrate camera viewing angle.
12.3 Facial Access Control Terminal
Common Failures
- Authentication failure: Non-standard facial/fingerprint entry, abnormal living body detection, expired permissions. Troubleshooting: Re-enter biometric information, calibrate living body detection, update permissions.
- No door opening response: Power failure of access terminal, damaged lock body, broken wiring. Troubleshooting: Inspect power, replace lock body, repair wiring.
- False alarm: Faulty anti-pry sensor, loose installation. Troubleshooting: Replace sensor, re-fix equipment.
- Failed data upload: Network disconnection, offline platform. Troubleshooting: Inspect network, restart platform.
Maintenance Schedule
- Daily: Test authentication function, door opening response speed and alarm function.
- Weekly: Clean facial lens and fingerprint collection area, inspect equipment installation stability.
- Monthly: Reboot access terminal, upgrade firmware, back up authentication data, inspect aging wiring.
- Annual: Test lock body performance, replace aging accessories, calibrate living body detection parameters.
12.4 UPS Uninterruptible Power Supply
Common Failures
- Instant shutdown after mains power cut: Aged batteries, insufficient capacity. Troubleshooting: Replace battery pack.
- Abnormal output voltage: Inverter failure, overload. Troubleshooting: Repair inverter, reduce load capacity.
- Abnormal fan noise / stalled fan: Damaged fan, excessive dust accumulation. Troubleshooting: Clean dust, replace fan.
- Frequent alarms: Overload, faulty battery, overheating. Troubleshooting: Inspect load, replace battery, improve heat dissipation.
Maintenance Schedule
- Daily: Check UPS operating status, input/output voltage, battery level and alarm messages.
- Weekly: Clean dust on UPS body, inspect fan operation.
- Monthly: Conduct one discharge test (discharge to 20% battery level under mains mode), test battery health.
- Annual: Replace battery pack (service life 3-5 years), test inverter performance, calibrate output voltage.
12.5 Network Security Equipment (Gateway / Encrypted Switch / Cipher Machine)
Common Failures
- Failed data ferry (Gateway): Disconnected internal/external network, incorrect policy configuration. Troubleshooting: Inspect network, reconfigure ferry policies.
- Abnormal encrypted transmission (Switch / Cipher Machine): Expired key, algorithm failure. Troubleshooting: Update key, restart equipment, upgrade firmware.
- Equipment offline: Power failure, broken network cable. Troubleshooting: Inspect power, replace cable.
Maintenance Schedule
- Daily: Check equipment online status, data transmission logs and alarm messages.
- Weekly: Reboot equipment, clean body dust, inspect network connections.
- Monthly: Back up configuration files, upgrade firmware, update encryption keys, inspect redundant power supply.
- Annual: Test hardware performance, replace aging accessories, optimize security policies.
12.6 Classified Carrier Management Equipment
Common Failures
- Failed RFID reading: Damaged tag, faulty reader, excessive reading distance. Troubleshooting: Replace tag, repair reader, adjust reading distance.
- Unable to open confidential cabinet: Authentication failure, damaged lock body, power failure. Troubleshooting: Re-authenticate, replace lock body, inspect power supply.
- Failed data synchronization: Network disconnection, offline platform. Troubleshooting: Inspect network, restart platform.
Maintenance Schedule
- Daily: Test RFID reading function and confidential cabinet authentication & door opening function.
- Weekly: Clean reader antenna and cabinet lock body, inspect equipment stability.
- Monthly: Reboot equipment, upgrade firmware, back up carrier data, inspect aging wiring.
- Annual: Test lock body and reader performance, replace aging accessories, calibrate RFID reading parameters.
13. Factory Strength & After-Sales Service
13.1 Factory Strength
KITOZER brand belongs to Guangzhou Laian Intelligent System Development Co., Ltd., a leading domestic provider of integrated intelligent solutions for classified premises with 15 years of R&D, production, sales and service experience in classified intelligent equipment.
- R&D Capacity: A professional R&D team of 50 personnel including confidentiality technical specialists, national cryptographic algorithm engineers and AI algorithm engineers. Over 30 classified technology patents and 50 software copyrights obtained. All products passed national confidentiality certification, national cryptography certification and Classified Protection of Cybersecurity certification.
- Production Scale: Self-built 10,000㎡ modern production base equipped with SMT chip mounters, automated production lines, high-low temperature test chambers and aging test equipment. Annual production capacity reaches 100,000 sets with sufficient stock of core products, supporting bulk customization and OEM & ODM processing.
- Quality Control: Strictly complies with ISO9001 Quality Management System, ISO14001 Environmental Management System and Military Quality System. Every product undergoes 72-hour aging test, high-low temperature test, waterproof & dustproof test and encryption performance test with 100% qualification rate, guaranteed by military-grade quality standards.
- Supply Chain Guarantee: Core components adopt domestic first-tier brands for full independent controllability without supply interruption risks. A complete supply chain system ensures stable raw material supply and shortened delivery cycles.
13.2 After-Sales Service
KITOZER provides exclusive confidentiality-grade after-sales service following the service philosophy of “Rapid Response, Professional Disposal, Full Confidentiality, Lifelong Maintenance” to guarantee stable operation of classified systems.
- 7×24 Technical Support: National unified service hotline with 7×24 online service. Response to consultation and fault repair within 10 minutes, remote technical guidance for rapid problem resolution.
- Localized Service Teams: 30 service outlets nationwide covering all provinces and cities with professional confidential technical engineers. On-site service within 24 hours (48 hours for remote areas) including installation, commissioning, maintenance and regular inspection.
- Warranty Commitment: All products enjoy free 3-year warranty (5-year warranty for core components) with free repair and accessory replacement during warranty period. Lifelong maintenance service available after warranty expiration, only charging accessory cost.
- Confidential Service Commitment: All after-sales engineers receive confidentiality training and background review, signing confidentiality agreements. All service processes are fully confidential without leakage of classified premises information, system configuration and data content, complying with confidentiality laws and regulations.
- Customized Training Service: Free training on system operation, maintenance and confidentiality (online + offline) to ensure operators master system operation and daily maintenance skills proficiently.
- Emergency Support Service: Exclusive emergency support teams for major classified projects with regular inspections to eliminate hidden dangers in advance. Priority disposal for sudden faults to restore system operation rapidly.
14. Conclusion
The Intelligent Integrated System for Classified Premises serves as core infrastructure to secure classified premises, prevent information leakage and improve management efficiency. With independently controllable technology, military-grade quality, customized solutions and confidentiality-grade services, KITOZER delivers full-series, one-stop, high-security integrated intelligent solutions for Party and government organs, military industrial enterprises and research institutes.
Strictly compliant with confidentiality laws and industry standards, this solution covers all security grades from Basic to Fortress. It builds a closed-loop security protection system of “Prevent in Advance, Control During Incidents, Trace After Incidents” covering system design, product selection, integrated deployment and operation & maintenance, fully protecting personnel, equipment, environments, carriers and networks within classified premises.
In the future, KITOZER will continue to deepen the classified intelligent field, increase R&D investment, optimize product performance and upgrade service quality. With more advanced technology, reliable products and professional services, we will assist classified institutions in building solid security defense lines and contribute to national confidentiality undertakings.
15. SEO & Tags
15.1 Core Primary Keywords
Intelligent Integrated System for Classified Premises, Confidential Intelligent Management Platform, Confidential Security System, Intelligent Solution for Confidential Computer Rooms, Security Protection System for Classified Premises
15.2 High-Conversion Long-Tail Keywords
KITOZER classified intelligent solution, classified office system for Party and government organs, core classified area management solution for military industry, intelligent system for classified archives warehouses, UPS power supply solution for confidential computer rooms, facial access control system for classified premises, network security isolation equipment
15.3 Industry Traffic Keywords
Intelligent Integrated System, Security Monitoring System, Access Control Equipment, Environmental Monitoring System, Network Security Equipment, Classified Carrier Management System, Perimeter Alarm System, UPS Uninterruptible Power Supply
15.4 Brand Exclusive Keywords
KITOZER, KITOZER classified equipment, KITOZER intelligent management platform, KITOZER security products, Guangzhou Laian Intelligence
15.5 Drop-Down & Related Search Keywords
Manufacturer of Intelligent Integrated System for Classified Premises, Price of Confidential Intelligent Management Platform, Confidential security system solution, Construction standards for confidential computer rooms, RFID management system for classified carriers, National cryptographic encrypted switch, Manufacturer of anti-tailgating interlocking doors
15.6 SEO Optimization Tag System
Core Page Optimization Tag
Intelligent Integrated System Solution for Classified Premises _ KITOZER Confidential Intelligent Management Platform _ Guangzhou Laian Intelligence
Title Tag
Intelligent Integrated System Solution for Classified Premises – KITOZER Confidential Security System – Guangzhou Laian Intelligence
Meta Keywords Tag
Intelligent Integrated System for Classified Premises, Confidential Intelligent Management Platform, Confidential Security System, Intelligent Solution for Confidential Computer Rooms, KITOZER, Guangzhou Laian Intelligence
Meta Description Tag
KITOZER provides Intelligent Integrated System Solutions for Classified Premises, covering confidential intelligent management platforms, facial access control, video surveillance, environmental monitoring and network security equipment. Applicable to Party and government organs, military industrial enterprises and research institutes with independent controllability, security & confidentiality and customized design, military-grade quality and confidentiality-grade after-sales service.
H1 Tag
Intelligent Integrated System Solution for Classified Premises
H2 Tags
System Overview, System Composition, System Classification, System Schematic Principle, System Configuration List, Product Technical Parameters, Product Application Scope, Product Advantages, Bid-Winning Core Parameters, Targeted Product Solutions, Application Cases, Common Product Failures & Maintenance, Factory Strength & After-Sales Service, Conclusion
Internal Link Optimization Anchor Text
- Core Anchor Text: Intelligent Integrated System for Classified Premises, Confidential Intelligent Management Platform, Confidential Security System
- Long-Tail Anchor Text: KITOZER classified intelligent solution, Intelligent Solution for Confidential Computer Rooms, Intelligent System for Classified Archives Warehouses
- Related Anchor Text: Facial Access Control System, Network Security Isolation Equipment, UPS Uninterruptible Power Supply, Perimeter Alarm System
这篇文章的主题是什么?
文章中提到了哪些技术?
文章中提到的技术有哪些应用场景?