KITOZER 1000A ATS Automatic Transfer Switch Main Switchboard

The KITOZER 1000A automatic transfer switch is a heavy-duty main switchboard solution for large facilities requiring dual-source power continuity. Rated at 1000A, 400V three phase, it handles the full load of mid-size data centers, hospitals, shopping malls, and industrial plants. Built with an electrically operated, mechanically interlocked breaker, the ATS transfers between utility and generator in under 100 milliseconds while maintaining zero-break continuity for critical downstream UPS systems.

Product Overview

The floor-standing cabinet houses two molded case circuit breakers on a common bus, with a mechanical and electrical interlock ensuring only one source closes at a time. A microprocessor-based ATS controller monitors both sources, manages generator start, and logs events. The front door includes a touchscreen HMI showing voltage, current, power, and breaker position. A maintenance bypass switch allows safe servicing of the ATS while the load remains energized. The cabinet includes surge protection and auxiliary contacts for remote indication.

Technical Specifications

Rated current is 1000A. Rated voltage is 400V three phase, 50 Hz. Short-time withstand is 50 kA for 1 second. Transfer time is under 100 milliseconds. Mechanical interlock double ensure break-before-make. Controller monitors three-phase voltage, frequency, and phase rotation on both sources. Programmable voltage window, start delay, re-transfer delay, and cool-down. Load current metering on outgoing feed. Event log stores 500 events with timestamp. Communication: Modbus TCP, SNMP, Web HMI. Maintenance bypass allows live servicing. Cabinet dimensions are 1000 mm wide, 2200 mm high, 800 mm deep. Weight is approximately 650 kg. IP42 indoor. Compliance with IEC 60947-6-1 and IEC 61439.

Applications

The 1000A ATS serves as the main transfer switch for data center UPS input, hospital life safety systems, hotel emergency power, manufacturing process lines, and large commercial buildings. It pairs with 800 to 1000 kW generator sets. In utility substations, it switches between two utility feeds for sensitive loads. The maintenance bypass is critical for facilities that cannot afford shutdown even for ATS servicing.

Key Advantages

The heavy-duty breaker design provides high short-circuit withstand and long electrical life. The maintenance bypass eliminates planned downtime. The touchscreen HMI simplifies operation and diagnostics. Remote communication integrates with DCIM and BMS. The event log supports compliance reporting. The cabinet is factory-tested under load before shipment. Multiple units can be paralleled with upstream generator paralleling schemes.

Installation and Maintenance Advice

Install the ATS on a reinforced floor with front and rear access. Size incoming and outgoing cables for 1000A continuous current. Verify phase rotation on both sources. Set voltage windows and delays. Test transfer by opening the utility breaker. Calibrate current transformers. Inspect breaker contacts every 3 years. Tighten busbar joints annually. Test maintenance bypass operation annually. Keep spare auxiliary contacts. The cabinet must be bonded to the station ground.

Price

From $12,500 per ATS cabinet, ex works. Contact us for project engineering and single-line diagram support.