KITOZER
KITOZER

KITOZER 1000kVA American Box Type Substation 10kV Pad Mounted

Product Overview

The KITOZER 1000kVA American style box type substation is a compact pad mounted unit integrating a 10kV oil immersed transformer, high voltage load break switch, and low voltage distribution board into one weatherproof enclosure. Designed for the North American style loop feed or radial feed, the unit is widely used in commercial complexes, residential subdivisions, business parks, and urban infrastructure. KITOZER builds the enclosure from powder coated steel with bolted removable panels for easy front and rear maintenance access, minimizing footprint and installation cost.

Technical Specifications

Transformer rating 1000kVA, 10kV delta to 400V wye, Dyn11. HV side: two way loop feed or radial feed, 600A load break elbows, 900A bus. LV side: main breaker 1600A, up to 12 feeder outgoing circuits with molded case breakers. Transformer impedance 5.5 percent, off circuit taps plus or minus 2 by 2.5 percent. Enclosure NEMA 3R powder coated steel, color on request. Temperature rise 65K, ONAN cooling. Pressure relief device, oil level gauge, silica gel breather. Ground bus bar and internal lighting. Weight approximately 5200kg, dimensions 3000mm by 2000mm by 2200mm. Standards ANSI C57.12, IEC 60076, IEEE, CE.

Application Scenarios

This American pad mounted substation is ideal for shopping mall ring mains, university campus distribution, hospital grounds, residential subdivisions, and outdoor data center expansion. It is also used for temporary construction power and event venue supply. The loop feed configuration allows maintenance without interrupting downstream customers.

Advantages and Features

Compact all in one design reduces civil works and cabling. Loop feed elbows allow live maintenance. NEMA 3R enclosure resists rain, sleet, and external ice. KITOZER offers options including surge arresters, fault indicators, power meter, and remote SCADA communication. The bolted panel construction allows full access to transformer, HV switch, and LV breakers. Factory assembled and tested before shipment reduces on site commissioning time.

Installation and Maintenance

Mount on a reinforced concrete pad with a 100mm plinth. Keep 1500mm clearance on front and rear for panel opening. Connect HV elbows with proper torque and load break tool. LV cables enter through bottom gland plates. Annual maintenance includes oil test, breaker mechanical operation check, enclosure door gasket inspection, and corrosion touch up. KITOZER recommends thermographic scanning of LV busbar under full load.

Construction and Quality Assurance

The American style cabinet is fabricated from 2mm galvanized steel with a powder coated finish. The transformer inside is a fully sealed oil immersed unit with corrugated fins. The HV elbow load break switches are rated for 600A loop feed with visible break. The LV compartment houses main and feeder breakers on a dead front panel. Every unit undergoes a routine test including power frequency, protection relay operation, and interlock check. KITOZER provides a one line diagram, foundation drawing, and test report. NEMA 3R enclosure rating is verified by enclosure protection test.

Packaging and After Sales

The substation is shipped on a steel skid, ready for crane placement. KITOZER provides installation and commissioning support. The 5 year warranty covers transformer, HV switch, and LV breakers. Spare elbows, fuses, and breakers are stocked. For commercial property managers, KITOZER offers an annual inspection contract including oil sample and breaker test.

Price

From $18,800/pc. Contact +86 13922289957 for box substation price.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com