KITOZER 1000kW Generator Synchronizing Panel for Data Center N+1

Product Overview

The KITOZER 1000kW generator synchronizing panel is a high capacity paralleling switchboard engineered for mission critical data center standby plants with N plus 1 or 2N generator redundancy. Each generator breaker feeds a common low voltage bus that supplies the UPS system through an automatic transfer main breaker. KITOZER integrates a dedicated paralleling controller with load management, base load utility interplay, and scheduled exercise testing. The panel is built to withstand high short circuit levels and to support remote monitoring by the BMS and DCIM platforms.

Technical Specifications

Per genset 1000kW, 400V, 50Hz, rated current 1800A. Generator air circuit breakers 2000A, 3 pole, drawout, with shunt trip, undervoltage, and closing coil. Main bus 4000A, copper, 100kA for 1 second. Synchronizing controller with automatic voltage, frequency, and phase matching, close within 3 degrees. Load share line, kW and kVAr droop or isochronous. Protection relays: overcurrent, earth fault, reverse power, over excitation, over speed, under speed. Utility intertie breaker 4000A with synchronism check. Communication: Modbus TCP, SNMP, BACnet, dry contacts. Panel IP31, floor standing, double skin. Standards IEC 61439, GB 7251, CE, UL listed option.

Application Scenarios

This panel is deployed in Tier 3 and Tier 4 data centers, hyperscale computing campuses, and large cloud facilities. It supports 2N redundant power paths and allows staged generator addition as IT load grows. It also serves as the paralleling board for hospital central plants, broadcast studios, and financial transaction centers.

Advantages and Features

The drawout breaker design allows breaker withdrawal without de energizing the bus. Load management starts and stops generators based on actual load, saving fuel and reducing runtime hours. The controller logs every event with timestamp for compliance reporting. KITOZER offers a redundant controller option, a 15 inch touchscreen HMI, and a remote Web dashboard. Factory SAT includes a full load bank test and simulated mains failure sequence.

Installation and Maintenance

Install on a dedicated generator room floor with 1200mm front and rear clearance. Bond the neutral and ground per single or double source configuration. Calibrate current transformers before commissioning. Test each generator breaker trip coil and shunt trip. Annual maintenance includes breaker contact resistance test, controller battery backup check, and a full load bank test at 25, 50, 75, 100 percent. KITOZER recommends quarterly automatic exercise testing under no load.

Construction and Quality Assurance

The data center synchronizing panel is built from double skin sheet steel with internal wire ways. The drawout air circuit breakers are fitted with racking screws and position indicators. The copper busbar is sized for 4000A continuous and 100kA short time. The synchronizing controller is mounted on the door with a 10 inch touchscreen. Every panel undergoes a full simulated load test using a load bank, and KITOZER provides a FAT report including generator start, parallel, and load transfer sequence. Factory witness testing is offered for Tier 3 and Tier 4 data center customers.

Packaging and After Sales

The panel is shipped in a plywood case with the breakers in the disconnected position. KITOZER provides commissioning support and operator training. The 2 year warranty covers controller, breakers, and busbar. Spare controllers, breakers, and auxiliary contacts are stocked. A 24 hour on site response service is available for data center customers.

Price

From $19,800/pc. Contact +86 13922289957 for data center sync panel quote.