KITOZER 100 A high-current power EMI filter is designed for main distribution feeders of data centers, industrial power panels, and large UPS systems where conducted noise from upstream switching converters must be contained. The filter attenuates high-frequency noise on three-phase plus neutral feeders, protecting downstream IT loads, storage arrays, and network switches from conducted susceptibility issues. The modular chassis design allows installation in standard Rittal-style enclosures or floor-mounted switchboards, and the symmetrical Y-capacitor network minimizes neutral-to-ground noise that can interfere with sensitive measurement and grounding systems.
Table of Contents
ToggleTechnical Specifications
Rated voltage 400 V AC three phase plus neutral, rated current 100 A at 40 degrees Celsius, frequency 50 or 60 Hz, common-mode attenuation up to 85 dB at 10 MHz, differential-mode attenuation up to 65 dB at 100 kHz, leakage current below 5 mA, dielectric strength 2800 V AC, operating temperature minus 25 to plus 85 degrees Celsius, enclosure IP20, busbar terminals 25 mm2 and above, certified UL, CE, RoHS, dimensions approximately 360 by 180 by 120 mm, weight 6.5 kg.
Applications
The 100 A filter is installed on UPS output feeders, PDU mains, diesel generator input panels, battery energy storage system converters, and large VFD bypass cabinets. It is also used in broadcast transmitter plants, medical imaging suites, and scientific research facilities where radiated noise from power electronics must not raise the noise floor on sensitive measurement equipment.
Advantages and Features
KITOZER high-current filters use segmented nanocrystalline cores distributed across multiple winding sections to avoid saturation under DC bias from non-linear loads. The low-profile busbar entry reduces stray inductance, and the steel chassis provides magnetic shielding to prevent external coupling. Units are tested for full-rated current at elevated temperature and shipped with a factory test report. Custom taps, warning labels, and conformal coating are available for harsh environments.
Installation and Maintenance
Mount the filter on a flat conductive panel and bond the chassis to the protective earth with short, wide straps. Keep input and output cable trays separated by at least 200 mm, and avoid looping conductors near the filter. Torque busbar lugs to the manufacturer specification, and verify the PE bond before energizing. During commissioning, measure conducted emissions with a LISN to confirm margins. Re-torque connections after the first thermal cycle, and inspect annually in mission-critical installations.
Price
From $680 per piece. Contact +86 13922289957 for high-current filter pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com