KITOZER 100kVA Dry Type Distribution Transformer 10kV To 400V

Product Overview

The KITOZER 100kVA dry type distribution transformer steps down 10 kV medium voltage to 400 V three phase low voltage for commercial buildings, data centers, and industrial plants. With epoxy resin encapsulated windings and a class F insulation system, the transformer delivers 100 kVA continuous power with low no load loss and low noise. The unit is designed for indoor installation in transformer rooms, and it can be fitted with an enclosure, temperature controller, and fan cooling for higher ambient conditions.

Technical Specifications

Rated power: 100 kVA. Primary voltage: 10 kV plus or minus 2 x 2.5 percent. Secondary voltage: 400 V three phase. Frequency: 50 or 60 Hz. Connection: Dyn11. Insulation class F, temperature rise 100 K. No load loss 300 W, load loss 1500 W at 120 degrees. Impedance 4 percent. Noise level 55 dB(A). Cooling: AN, optional AF with fans. Protection: IP00 open, IP23 or IP31 enclosure optional. Standards CE, IEC 60076, KITOZER 5 year warranty.

Application Scenarios

The 100 kVA transformer is used at small commercial buildings, retail centers, and factory workshops that draw 80 to 100 kW of continuous load. It is also specified at edge data centers, telecom exchanges, and hospital wings that need dedicated transformer capacity. The dry type design is preferred in indoor locations where oil filled transformers would pose a fire risk.

Advantages and Features

Epoxy resin encapsulation provides excellent resistance to dust and moisture, which extends service life in harsh environments. Low no load loss reduces standby energy cost, which matters for transformers that run 24/7. The Dyn11 connection suppresses harmonic neutral current, which protects connected loads. The optional temperature controller and fan cooling allow the transformer to deliver up to 20 percent extra capacity in hot ambient. The unit is free of PCB and mineral oil, so no oil containment pit is required.

Installation and Maintenance

Place the transformer on a level concrete floor in a ventilated transformer room with at least 300 mm clearance on all sides. Connect the MV side via a 200 A load break switch, and the LV side to the main distribution panel via a 250 A MCCB. Earth the transformer tank and neutral bar separately. Commissioning includes insulation resistance test and turns ratio check. Annual maintenance includes tightening terminals, cleaning the epoxy surface, and verifying the temperature controller calibration.

Price

From $1,880 per unit. Contact plus 86 13922289957 for enclosure and fan options.