KITOZER
KITOZER

KITOZER 100kVA Dry Type Distribution Transformer 10kV To 400V

Product Overview

The KITOZER 100kVA dry type distribution transformer steps down 10 kV medium voltage to 400 V three phase low voltage for commercial buildings, data centers, and industrial plants. With epoxy resin encapsulated windings and a class F insulation system, the transformer delivers 100 kVA continuous power with low no load loss and low noise. The unit is designed for indoor installation in transformer rooms, and it can be fitted with an enclosure, temperature controller, and fan cooling for higher ambient conditions.

Technical Specifications

Rated power: 100 kVA. Primary voltage: 10 kV plus or minus 2 x 2.5 percent. Secondary voltage: 400 V three phase. Frequency: 50 or 60 Hz. Connection: Dyn11. Insulation class F, temperature rise 100 K. No load loss 300 W, load loss 1500 W at 120 degrees. Impedance 4 percent. Noise level 55 dB(A). Cooling: AN, optional AF with fans. Protection: IP00 open, IP23 or IP31 enclosure optional. Standards CE, IEC 60076, KITOZER 5 year warranty.

Application Scenarios

The 100 kVA transformer is used at small commercial buildings, retail centers, and factory workshops that draw 80 to 100 kW of continuous load. It is also specified at edge data centers, telecom exchanges, and hospital wings that need dedicated transformer capacity. The dry type design is preferred in indoor locations where oil filled transformers would pose a fire risk.

Advantages and Features

Epoxy resin encapsulation provides excellent resistance to dust and moisture, which extends service life in harsh environments. Low no load loss reduces standby energy cost, which matters for transformers that run 24/7. The Dyn11 connection suppresses harmonic neutral current, which protects connected loads. The optional temperature controller and fan cooling allow the transformer to deliver up to 20 percent extra capacity in hot ambient. The unit is free of PCB and mineral oil, so no oil containment pit is required.

Installation and Maintenance

Place the transformer on a level concrete floor in a ventilated transformer room with at least 300 mm clearance on all sides. Connect the MV side via a 200 A load break switch, and the LV side to the main distribution panel via a 250 A MCCB. Earth the transformer tank and neutral bar separately. Commissioning includes insulation resistance test and turns ratio check. Annual maintenance includes tightening terminals, cleaning the epoxy surface, and verifying the temperature controller calibration.

Typical System Configuration

A complete KITOZER installation typically includes the main unit, a matching distribution or protection accessory, a surge protective device, and a remote monitoring gateway. The system can be extended in phases as the load grows, which allows the customer to start with a smaller footprint and add capacity later. The engineering team provides a single line diagram, a bill of materials, and a cable schedule with every project, so the electrical contractor can install the equipment without additional design work. Remote monitoring is available via web browser or mobile app, showing real time status, alarm history, and energy consumption trends. The system supports Modbus RTU, Modbus TCP, and SNMP for integration with building management or SCADA platforms. On site commissioning, operator training, and spare parts kits are available as optional services for turnkey projects.

Why Choose KITOZER

KITOZER has specialized in power electronics and energy infrastructure for over a decade, exporting to more than 60 countries across Europe, the Middle East, Southeast Asia, Africa, and Latin America. The product is designed and manufactured in a modern ISO 9001 certified facility, where every unit passes a 24 to 72 hour burn in test before packaging. The engineering team works directly with project developers, electrical contractors, and EPC firms to customize voltage, communication protocol, and enclosure rating to match local grid codes and site conditions. Competitive factory direct pricing reduces total project cost by 20 to 40 percent compared with equivalent imported brands, without compromising on safety certifications or warranty coverage. The KITOZER cloud platform provides lifetime free monitoring for the standard version, so operators can track performance and receive alarms from any browser or mobile device. For large projects, the application engineering team supports site design, cable sizing, protection coordination, and grid code filing, helping the customer move from concept to commissioning with a single point of contact.

Packaging Shipping and Support

The KITOZER 100kVA dry type transformer is packed in a heavy duty plywood crate with foam cushioning and desiccant bags for long sea transit. The crate is labeled with handling symbols, weight, and orientation marks, and it meets ISPM 15 requirements for international shipping. Standard lead time is 15 to 45 days depending on configuration, and rush production is available for urgent projects. Spare parts are held at regional warehouses in Europe, the Middle East, and Southeast Asia, ensuring four to eight hour response time for critical failures. The KITOZER support team provides remote commissioning guidance over video call, and on site commissioning can be arranged for turnkey projects. Every unit ships with a printed quick start guide, a USB stick containing the full user manual in English, and a factory test report. Extended warranty up to 10 years is available on request for mission critical installations.

Price

From $1,880 per unit. Contact plus 86 13922289957 for enclosure and fan options.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart