ToggleProduct Overview
The KITOZER 100kVA dry type transformer is a cast resin encapsulated distribution transformer designed for stepping down 10kV medium voltage to 400V three phase low voltage in commercial, industrial, and infrastructure projects. Unlike oil filled units, this dry type transformer uses vacuum cast epoxy resin to fully encapsulate both the high voltage and low voltage windings, completely eliminating fire risk, oil leakage, and environmental contamination. The core is built from high permeability grain oriented silicon steel laminations with step lap construction to reduce no load loss and exciting current while keeping audible noise to a minimum. KITOZER engineers each unit for continuous duty, low audible noise, and reliable operation in indoor installations where fire safety and low maintenance are critical. The compact footprint and light weight make the 100kVA unit ideal for rooftop transformer rooms, basements, and retrofit projects where space is limited.
Technical Specifications
Rated power is 100kVA with a primary voltage of 10kV and secondary voltage of 400V, suitable for three phase 50Hz power systems worldwide. The vector group is Dyn11, impedance voltage is 4 percent, and insulation class is F with a temperature rise limit of 100K over a 40 degree ambient. Cooling method is AN air natural convection as standard, with optional AF forced air fans to deliver up to 40 percent overload when required. Protection enclosure is IP00 for open indoor transformer rooms, with optional IP21, IP23, or IP31 sheet steel or aluminum enclosure for dusty or damp environments. Tap range is plus or minus 2.5 percent off circuit tap changer on the HV side. Temperature monitoring includes PT100 sensors embedded in the windings connected to a digital controller with fan start, pre alarm, and trip dry contacts. Standard compliance includes IEC 60076, GB/T 1094, GB/T 6451, and CE marking. Noise level is below 55dB at one meter. Weight is approximately 680kg and overall dimensions are 1150mm by 750mm by 1250mm. Routine factory tests include ratio measurement, DC resistance, no load loss, load loss, induced voltage withstand, and partial discharge check below 10pC.
Application Scenarios
This 100kVA dry type transformer is widely used in shopping malls, office towers, hospitals, schools, hotels, underground parking lots, and indoor substations where oil filled transformers are prohibited by local fire code. It is also suitable for data center edge rooms, industrial process plants, water treatment stations, and renewable energy grid tie applications such as solar PV inverter step up. Because the unit produces no oil spill risk, it can be installed in basements, high rise building transformer rooms, and adjacent to public areas without additional bunding. The compact footprint makes it ideal for retrofit projects where space is constrained and where a conventional oil pad would not fit. It commonly feeds low voltage distribution panels, motor control centers, HVAC chillers, and lighting busways in buildings up to ten floors.
Advantages and Features
The cast resin winding is moisture proof, dust resistant, and short circuit proof, allowing operation in humid or dusty environments without derating. The step lap core reduces no load loss by up to 30 percent compared with conventional stack cores, lowering annual electricity cost over the 30 year service life. The Dyn11 vector group suppresses triplen harmonic currents and provides a stable neutral point for single phase loads. Built in PT100 thermal sensors protect against over temperature with both alarm and trip thresholds. KITOZER offers optional forced air cooling fans, an enclosure with ventilation louvers, and an RS485 Modbus communication module for remote monitoring from a building management system. Every unit undergoes routine tests before shipment and is supplied with a factory test certificate. The stainless steel nameplate and corrosion resistant enclosure coating ensure decades of outdoor or semi outdoor service.
Installation and Maintenance
Install the transformer on a level concrete or steel foundation with adequate clearance for cable entry and cooling air flow. Maintain at least 300mm clearance on sides and 500mm on top to allow natural convection. Ensure intake air temperature stays below 40 degrees Celsius and does not exceed 20 degrees Celsius average over a 24 hour period. Connect the HV and LV cables with properly sized copper or aluminum lugs and torque to the manufacturer specification. Periodically inspect winding insulation resistance with a 2500V megohmmeter, tighten busbar bolts, clean dust from cooling ducts, and verify thermal sensor calibration. KITOZER recommends annual preventive maintenance by a qualified electrician and a full insulation resistance test every three years. In dusty environments, clean the winding surface with dry compressed air at least twice a year to maintain cooling efficiency.
Construction and Quality Assurance
KITOZER windings are wound with oxygen free copper conductors and fully vacuum cast in epoxy resin to eliminate voids. The core is annealed after cutting and finished with epoxy coated laminations to reduce vibration. Every core and coil assembly passes a partial discharge test at 1.5 times rated voltage, and every completed transformer undergoes a full routine test schedule. The factory is ISO 9001 certified and traceability records are kept for steel, copper, and resin batches. This quality discipline ensures consistent performance across units and supports the 5 year warranty.
Price