The KITOZER 100kVA dry type transformer is a cast resin encapsulated distribution transformer designed for stepping down 10kV medium voltage to 400V three-phase low voltage in commercial, industrial, and infrastructure projects. Unlike oil filled units, this dry type transformer uses vacuum cast epoxy resin to fully encapsulate the high voltage and low voltage windings, eliminating fire risk, oil leakage, and environmental contamination. The core is built from high permeability grain oriented silicon steel laminations with step lap construction to reduce no load loss and exciting current. KITOZER engineers each unit for continuous duty, low audible noise, and reliable operation in indoor installations where fire safety and low maintenance are critical.
Technical Specifications
Rated power is 100kVA with a primary voltage of 10kV and secondary voltage of 400V, suitable for three phase 50Hz systems. The vector group is Dyn11, impedance voltage is 4 percent, and insulation class is F with temperature rise limit of 100K. Cooling method is AN (air natural) with optional AF (air forced) fans to deliver up to 40 percent overload. Protection enclosure is IP00 for indoor transformer rooms, with optional IP21, IP23, or IP31 sheet steel or aluminum enclosure. Tap range is plus or minus 2.5 percent off circuit tap changer on the HV side. Temperature monitoring includes PT100 sensors embedded in the windings connected to a digital controller with fan start, alarm, and trip contacts. Standard compliance includes IEC 60076, GB/T 1094, GB/T 6451, and CE marking. Noise level is below 55dB at one meter. Weight is approximately 680kg and dimensions are 1150mm by 750mm by 1250mm.
Application Scenarios
This 100kVA dry type transformer is widely used in shopping malls, office towers, hospitals, schools, hotels, underground parking lots, and indoor substations where oil filled transformers are prohibited by fire code. It is also suitable for data center edge rooms, industrial process plants, water treatment stations, and renewable energy grid tie applications such as solar PV inverter step up. Because the unit produces no oil spill risk, it can be installed in basements, high rise building transformer rooms, and adjacent to public areas. The compact footprint makes it ideal for retrofit projects where space is constrained.
Advantages and Features
The cast resin winding is moisture proof, dust resistant, and short circuit proof, allowing operation in humid or dusty environments without derating. The step lap core reduces no load loss by up to 30 percent compared with conventional stack cores, lowering annual electricity cost. The Dyn11 vector group suppresses harmonic currents and provides neutral point grounding for single phase loads. Built in PT100 thermal sensors protect against over temperature with both alarm and trip thresholds. KITOZER offers optional forced air cooling fans, an enclosure with ventilation louvers, and a RS485 Modbus communication module for remote monitoring. Every unit undergoes routine tests including ratio measurement, resistance measurement, no load loss, load loss, and induced voltage withstand before shipment.
Installation and Maintenance
Install the transformer on a level concrete or steel foundation with adequate clearance for cable entry and cooling air flow. Maintain at least 300mm clearance on sides and 500mm on top. Ensure intake air temperature stays below 40 degrees Celsius and does not exceed 20 degrees Celsius average over 24 hours. Connect the HV and LV cables with properly sized lugs and torque to manufacturer specification. Periodically inspect winding insulation resistance with a 2500V megohmmeter, tighten busbar bolts, clean dust from cooling ducts, and verify thermal sensor calibration. KITOZER recommends annual preventive maintenance by a qualified electrician and a full insulation test every three years.
Price
From $2,380/pc. Contact +86 13922289957 for factory quotation and lead time.