KITOZER 100kW Containerized Energy Storage PCS

Product Overview

The KITOZER 100kW PCS is a floor standing bi directional inverter for commercial and industrial energy storage systems. It doubles the power rating of the 50 kW model while sharing the same control software and communication protocol. The unit is housed in a steel cabinet with front access, forced air cooling, and a 7 inch touch screen showing real time power, battery voltage, and grid status. Up to ten units can be paralleled to form a 1 MW storage plant, making the 100 kW PCS the default choice for medium sized commercial storage projects.

Technical Specifications

AC side: three phase 400 V, 50 or 60 Hz, 100 kW continuous. DC side: 400 to 820 Vdc battery, 200 A maximum. Efficiency 97.5 percent peak, 97 percent European. THDi less than 3 percent, power factor adjustable 0.8 leading to 0.8 lagging. Islanding detection compliant with IEEE 1547, VDE 0126, GB/T. Communication: CAN, Modbus TCP, Modbus RTU, Ethernet, optional 4G. Cooling: redundant forced air. Protection: DC over voltage, AC over voltage, islanding, over temperature, arc fault. Enclosure IP20, weight 150 kg, dimensions 700 by 600 by 1800 mm. Standards CE, IEC 62109, KITOZER 5 year warranty.

Application Scenarios

The 100 kW PCS is specified for 200 kWh to 500 kWh commercial storage cabinets used in shopping malls, hospital wings, and data center UPS augmentation. It is also the standard building block for 1 MWh shipping container storage systems that pair two 100 kW PCS units with a 215 kWh battery rack array. Microgrid projects on islands and remote telecom sites use the 100 kW PCS as the grid forming inverter, supplying stable 400 V three phase power when the utility is absent.

Advantages and Features

The grid forming function allows the PCS to build its own voltage and frequency reference in off grid mode, which means the system can start without a utility connection. Redundant fans ensure continuous operation even if one fan fails. The built in STATCOM function provides reactive power support to the local grid, which can earn additional revenue under ancillary service programs. Parallel operation supports hot swap, so a faulty PCS can be replaced while the rest of the array stays online.

Installation and Maintenance

Place the PCS on a level floor in a ventilated battery room. Connect the DC side to the battery rack via a 250 A DC breaker, and the AC side to the LV switchboard via a 250 A MCCB. Run the CAN daisy chain to the battery management system and to the site energy management controller. Commissioning includes setting the grid code, charge discharge schedule, and remote communication parameters. Annual maintenance covers fan filter cleaning, power terminal torque, and firmware update.