KITOZER Indirect Evaporative Cooler: 100kW Wet Bulb Economy

Product Overview

The KITOZER 100 kW indirect evaporative cooler (IEC) supplies clean, dry, conditioned air to data halls without mixing outside air into the occupied space. The unit uses a cross-flow heat exchanger: process air from the data hall passes through one side of the exchanger, while working air passes through the other side and is humidified at the surface. Evaporation cools the working air, which absorbs heat from the process air across the membrane. Because the two air streams never mix, IT equipment is never exposed to humidity, dust, or outdoor pollutants. A small trim DX coil handles peak-load days.

Technical Specifications

Rated cooling capacity is 100 kW at 26 degrees Celsius entering process air and 20 degree Celsius wet-bulb ambient. Process airflow is 20,000 cubic meters per hour. Working air exhaust is 10,000 cubic meters per hour. Saturation efficiency is 85 percent. Power supply is three phase 400 V 50 Hz, with fan power 4.5 kW and water pump 0.55 kW. Trim DX coil adds 30 kW for extreme days. Water consumption is 180 liters per hour at full evaporative load. Dimensions are 2800 mm wide by 1800 mm deep by 2500 mm high. Weight is 1450 kg. The controller supports Modbus TCP and BACnet IP.

Application Scenarios

Indirect evaporative coolers are used in data centers in dry, continental climates where wet-bulb temperatures remain below 22 degrees for most of the year. Typical sites include desert-edge cloud campuses, telecom central offices in inland regions, and industrial process cooling halls. They are also used in museums and archives where strict humidity control is required. The unit is equally suited to agricultural processing facilities and textile mills in dry regions. It is also used in museum climate zones and archival storage rooms where strict humidity control is required and outdoor air must not be mixed directly into the occupied space. The unit also supports a 4 to 20 mA external humidity signal, so it can be tied into a building-wide environmental control system.

Advantages and Features

Because the data hall air stream never mixes with outside air, contamination risk is zero. Evaporative cooling uses a fraction of the energy of mechanical refrigeration, yielding PUE values below 1.2 in dry climates. The unit has no compressor in the base mode, dramatically reducing moving parts. Water treatment includes a bleed-off loop and optional reverse-osmosis feed. The controller modulates working airflow to match wet-bulb conditions and automatically switches on the DX trim coil when outdoor wet-bulb exceeds threshold. A built-in web server exposes live trends and alarm history to any authorized browser on the local network. The unit also supports scheduled setpoint changes, so supply temperature rises automatically during low-utilization periods.

Installation and Maintenance Recommendations

Install the unit on a level concrete pad with duct connections to the data hall. Provide a municipal water feed with a pressure-reducing valve and a drain line sized for bleed-off. Clean the heat exchanger plates annually with low-pressure water. Inspect pump strainers monthly. Test UV water treatment quarterly. Replace ELAP pads every 3 to 5 years depending on water hardness. Commissioning should include a wet-bulb sensor calibration and a 24-hour process-air temperature stability test. A remote alarm forwarding module can send fault messages to a dedicated phone line or email address, so the site team is paged before a small issue becomes a room-temperature excursion. Operators should be trained on water bleed-off adjustment, pump strainer cleaning, and the procedure for switching the trim DX coil on or off seasonally.

Energy and Environmental Performance

Evaporative cooling uses roughly one tenth the energy of mechanical compression for the same cooling load. In dry climates, the unit can run in pure evaporative mode for 80 percent or more of the year. No refrigerants are used in the base cooling circuit. The water bleed-off loop prevents mineral buildup and can be routed to site irrigation. The unit qualifies for most green-building rating schemes targeting low-energy data centers. The controller also records energy use by mode, so sustainability teams can report annual evaporative-only hours and the corresponding carbon avoidance to management.

Configuration Options and Warranty

The unit is offered in multiple airflow sizes and with optional DX trim coils. Optional extras include a reverse-osmosis water feed, a UV disinfection lamp, a BACnet routing module, and a stainless-steel cabinet for coastal sites. The standard warranty covers the cabinet and fans for 2 years, with extended coverage up to 5 years available. A preventive maintenance package with annual plate cleaning is recommended. The package includes a plate wash, a pump strainer cleaning, and a water quality test every quarter.