The KITOZER 100kW indirect evaporative cooler (IEC) supplies clean, dry, conditioned air to data halls without mixing outside air into the occupied space. The unit uses a cross-flow heat exchanger: process air from the data hall passes through one side of the exchanger, while working air passes through the other side and is humidified at the surface. Evaporation cools the working air, which absorbs heat from the process air across the membrane. Because the two air streams never mix, IT equipment is never exposed to humidity, dust, or outdoor pollutants. A small trim DX coil handles peak-load days.
Technical Specifications
Rated cooling capacity is 100kW at 26 degrees Celsius entering process air and 20 degree Celsius wet-bulb ambient. Process airflow is 20,000 cubic meters per hour. Working air exhaust is 10,000 cubic meters per hour. Saturation efficiency is 85 percent. Power supply is three phase 400V 50Hz, with fan power 4.5kW and water pump 0.55kW. Trim DX coil adds 30kW for extreme days. Water consumption is 180 liters per hour at full evaporative load. Dimensions are 2800mm wide by 1800mm deep by 2500mm high. Weight is 1450kg. The controller supports Modbus TCP and BACnet IP.
Application Scenarios
Indirect evaporative coolers are used in data centers in dry, continental climates where wet-bulb temperatures remain below 22 degrees for most of the year. Typical sites include desert-edge cloud campuses, telecom central offices in inland regions, and industrial process cooling halls. They are also used in museums and archives where strict humidity control is required.
Advantages and Features
Because the data hall air stream never mixes with outside air, contamination risk is zero. Evaporative cooling uses a fraction of the energy of mechanical refrigeration, yielding PUE values below 1.2 in dry climates. The unit has no compressor in the base mode, dramatically reducing moving parts. Water treatment includes a bleed-off loop and optional reverse-osmosis feed. The controller modulates working airflow to match wet-bulb conditions and automatically switches on the DX trim coil when outdoor wet-bulb exceeds threshold.
Installation and Maintenance Recommendations
Install the unit on a level concrete pad with duct connections to the data hall. Provide a municipal water feed with a pressure-reducing valve and a drain line sized for bleed-off. Clean the heat exchanger plates annually with low-pressure water. Inspect pump strainers monthly. Test UV water treatment quarterly. Replace ELAP pads every 3 to 5 years depending on water quality.