The KITOZER 100kW open frame diesel generator set is engineered for standby and prime power duty in commercial, industrial, and construction environments where a sheltered equipment room is available. Built around a genuine Cummins 6CTA8.3-G2 diesel engine coupled with a KITOZER brushless alternator, this unit delivers dependable three-phase 400V output at 50Hz (or 480V at 60Hz on request). The open frame configuration lowers acquisition cost, simplifies servicing, and allows integration into existing genset rooms, sound-attenuated enclosures, or modular power stations. Every KITOZER 100kW set is factory-tested under load and supplied with full test certificates before shipment.
Table of Contents
ToggleProduct Overview
The open frame package consists of a heavy-duty welded steel base frame with integral fuel-sump, isolation mounts between engine and frame, a radiator cooling system sized for 50C ambient, a 12V starting motor, and a battery charger. The control panel is mounted on the alternator end and includes a DeepSea or ComAp controller with LCD display, LED alarm lamps, and RS485 Modbus communication. The base frame incorporates a 24-hour base fuel tank at 75 percent load, and a drain valve for maintenance. All cable connections are routed through protective conduit to prevent abrasion during operation. The unit is painted with epoxy primer and polyurethane topcoat in industrial gray, suitable for indoor installation with proper ventilation.
Technical Specifications
Prime power output is 100 kVA at 80 kW continuous standby rating up to 110 kVA. Engine displacement is 8.3 liters, inline six-cylinder, turbocharged and aftercooled. Fuel consumption at 75 percent load is approximately 21 liters per hour. Bore and stroke are 114 mm by 135 mm. Governor is electronic, maintaining frequency within plus or minus 0.5 percent steady state. Alternator is single-bearing, self-excited, brushless, with class H insulation and IP23 protection. Voltage regulation is plus or minus 1.5 percent. Frequency is 50 Hz at 1500 rpm. Starting voltage is 24V DC. Noise level at 7 meters in open air is approximately 102 dB(A). Dimensions are 2200 mm long, 950 mm wide, and 1400 mm high. Dry weight is approximately 1450 kg. Certifications include CE, ISO 8528, and relevant emission compliance for non-road mobile machinery.
Applications
This 100kW open frame set is widely used as standby power for small data rooms, retail malls, hospitals clinics, schools, office buildings, and water treatment plants. It also serves as prime power on construction sites, quarry plants, concrete batching stations, and remote mining camps where utility supply is absent or unreliable. In agricultural operations, it powers irrigation pumps, grain dryers, and poultry house ventilation systems. Telecom operators deploy it as backup power for base stations and microwave repeater sites. Because the open frame allows easy modification, it can be fitted with a customer-specified soundproof canopy, trailer chassis, or container housing for outdoor duty.
Key Advantages
The KITOZER 100kW set combines genuine Cummins power with a KITOZER alternator to achieve excellent fuel economy, long overhaul intervals, and broad parts availability worldwide. Electronic governor ensures stable voltage and frequency during sudden load steps, protecting sensitive electronics. The brushless alternator eliminates brush maintenance and provides superior short-circuit recovery. Isolation mounts reduce structure-borne noise and vibration. The control panel offers automatic mains failure starting, remote start contacts, and schedule-based exercise testing. A wide range of optional extras are available including water jacket heaters, battery float chargers, parallel kits, and custom base tank capacities.
Installation and Maintenance Advice
Install the unit on a level concrete foundation at least 150 mm thick, with enough clearance on all sides for radiator airflow and panel access. Route exhaust through an insulated pipe fitted with a flexible bellows and an industrial silencer, discharging away from air intakes. Maintain a dedicated ventilated room with air exchange calculated for radiator heat rejection. Use UL or IEC rated cables sized for 125 percent of rated current. Perform first service after 50 hours, then every 250 hours or annually: change engine oil and filter, fuel filter, and coolant. Inspect air filter differential indicator monthly. Exercise the set under at least 30 percent load once per month for 30 minutes to prevent wet-stacking. Store fuel with stabilizer if standby duty exceeds three months between run cycles.
Price
From $12,500 per set, ex works Guangzhou. Contact us for CIF delivery to your nearest port and full quotation including ATS, fuel tank, and commissioning support.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com