KITOZER
KITOZER

KITOZER PCS: 100kW Energy Storage Inverter C I &

The KITOZER 100kW power conversion system is a three-phase bi-directional inverter engineered for medium commercial and industrial storage projects. It bridges the gap between small 50kW behind-the-meter systems and 250kW container-class PCS, making it ideal for factories, warehouses, hospitals, and hotels that need 200kWh to 500kWh of battery capacity under a single inverter. The cabinet is built for indoor wall or floor installation and can be paralleled with up to twelve units to reach megawatt-scale without a separate master controller.

Product Overview

KITOZER designs the 100kW PCS with a three-level NPC topology and an LCL output filter, reaching 98.7 percent peak efficiency and near-sinusoidal current even under nonlinear loads. The controller supports grid-following and grid-forming modes, so the same unit can ride through faults on the grid and island to supply critical loads when the upstream breaker trips. A built-in STATCOM function provides reactive power support to the local bus, helping sites meet power factor penalty clauses without installing a separate SVG. The front LCD and web HMI show live DC and AC voltage, current, state of charge, and fault history, while the rear terminal block provides Modbus TCP, CAN, and dry contacts for plant integration.

Technical Specifications

Rated power 100kW, overload 110 percent for 10 minutes, 120 percent for 1 minute. DC voltage range 500 to 850V, optimized for 600V LFP clusters. AC output 400V three phase, 50 or 60Hz. Maximum efficiency 98.7 percent. THDi less than 3 percent. Power factor 0.8 adjustable. Response time to EMS command less than 20 milliseconds. Islanding per IEEE 1547, VDE 4105, and GB/T 19964. Cooling smart fan. IP20 indoor, optional IP54 outdoor kit. Dimensions 800 x 900 x 1900 millimeters, weight 320 kilograms. KITOZER five-year warranty.

Application Scenarios

The 100kW PCS is a workhorse for C and I storage projects: peak shaving at manufacturing plants with time-of-use tariffs, backup power for data cabinets in a small server room, and microgrid support at remote mining or agriculture sites. It pairs naturally with a 215kWh or 431kWh LFP battery cabinet, delivering a one-box storage skid that contractors can wheel into an electrical room and wire in a single day. Solar installers also use it as the hybrid heart of a PV-plus-storage rooftop system, where PV charges the battery during the day and the PCS discharges into the building in the evening.

Key Advantages

The three-level NPC topology reduces switching losses and keeps thermal stress on the IGBTs low, which translates into longer service life and quieter fans. Built-in STATCOM reactive support defers the cost of a separate power factor correction cubicle. Parallel operation without a master controller simplifies expansion, and the standard Modbus TCP integration works with most EMS platforms already deployed at customer sites. The wide 500 to 850V DC window lets integrators choose 600V or 700V battery racks without re-engineering the cabinet.

Installation and Maintenance

Mount the PCS on a concrete floor or a reinforced steel frame, and leave at least 600 millimeters on the fan side for hot-air discharge. Use shielded cable for the BMS CAN bus and ground the shield at one end to avoid loop currents. Commissioning must verify the grid code setting matches the local utility requirement, because voltage and frequency ride-through curves differ by region. Every two years, inspect the DC busbar torque and the fan filters, and every five years plan a capacitor inspection as part of preventive maintenance. KITOZER provides a remote OTA firmware update service for registered units.

Quality, Warranty and Delivery

KITOZER subjects every 100kW PCS to a four-hour load burn-in, a full grid-code test cycle, and an insulation test before it leaves the factory. The unit ships on a wooden pallet with a corrugated corner post, wrapped in anti-static film, and is accompanied by a factory test report, a USB stick with the manual and communication point list, a bag of spare fuses, and a pair of spare fan filters. For multi-unit projects, KITOZER offers pre-shipment witness testing at the factory, where the owner or EPC can verify efficiency, THD, and islanding behavior on a real battery cabinet. The five-year warranty covers the power stage, the controller, and the cooling fans, and can be extended to ten years with an annual preventive-maintenance contract. KITOZER keeps spare power modules and communication boards in regional warehouses, and provides remote OTA firmware updates for registered units so the grid-code library stays current as local regulations evolve.

Configuration and Ordering. KITOZER supplies each unit with the options specified at order placement, including the communication protocol, protection level, mounting orientation, and labeling language. Optional accessories such as external disconnect switches, surge protection kits, spare fuse sets, wall brackets, and remote monitoring gateways are available at a discount when ordered together with the main unit. The factory provides a final dimension and wiring drawing for customer approval before production starts, and the approved drawing becomes the manufacturing specification. Standard packaging is suitable for sea freight, and KITOZER can arrange air freight for urgent replacement orders on request. Every unit ships with a factory test report, a quick-start guide, and a bag of spare cable glands.

Price

From $11,800 per unit. Contact KITOZER for multi-unit project pricing and lead time.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com