KITOZER Water Cooled Condenser: 100kW Shell Tube

Product Overview

The KITOZER 100kW shell-and-tube water-cooled condenser is a pressure vessel designed to reject heat from refrigerant circuits to a circulating water loop. It is typically paired with a cooling tower, groundwater well, or closed-circuit cooler in central plant applications. Copper tubes mounted inside a steel shell provide high heat-transfer efficiency and easy mechanical cleaning. The condenser is supplied with refrigerant inlet and outlet flanges, water inlet and outlet flanges, safety relief valve, and sight glass.

Technical Specifications

Nominal heat rejection is 100kW at 32 degree Celsius condensing temperature and 30 degree Celsius entering water. Water flow is 21 liters per second. Water pressure drop is 40 kPa. Refrigerant side design pressure is 3.0 MPa. Water side design pressure is 1.0 MPa. Connection sizes are 3 inch water flanges and 2-5/8 inch refrigerant weld ends. The shell is carbon steel with internal anti-corrosion coating. Tubes are 0.5 mm thick copper. Dimensions are 1800mm long by 400mm diameter. Weight is 220kg dry.

Application Scenarios

This condenser is used in central chiller plants, industrial process refrigeration, marine HVAC, and district cooling stations. It is preferred where outdoor space for air-cooled condensers is unavailable, or where cooling tower water is already distributed. It is also used in high-rise buildings where rooftop loading is limited.

Advantages and Features

Water-cooled condensers achieve smaller condensing temperature differential than air-cooled units, raising chiller efficiency by 10 to 20 percent. Shell-and-tube construction is robust and serviceable: tubes can be mechanically rodded or chemically cleaned without removing the shell. The unit is rated for continuous 24/7 operation. A high-pressure safety relief valve and refrigerant sight glass aid commissioning and maintenance.

Installation and Maintenance Recommendations

Mount the condenser on a steel frame with vibration isolators. Install Y-strainers on the water inlet. Treat cooling tower water to prevent fouling and biological growth. Inspect tube wall thickness every three years via eddy-current test. Clean tubes annually if water quality is poor. Verify relief valve calibration every five years.

Price

From $2,680 per unit. Contact plus 86 13922289957 for shell-and-tube condenser pricing and selection.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com