The KITOZER 100kWh lithium iron phosphate battery cabinet is a plug-and-play energy storage block designed for commercial and industrial behind-the-meter installations. It houses LFP battery modules, a battery management system, fire detection, and a thermal management interface in a single floor-standing cabinet that can be wheel into an electrical room and wired to a 50kW or 100kW PCS. The cabinet is the building block for peak-shaving, backup power, and solar self-consumption projects in factories, supermarkets, schools, and small offices.
Table of Contents
ToggleProduct Overview
Inside the KITOZER 100kWh cabinet, sixteen 5.12kWh LFP modules are connected in series to form a 51.2V by 2P cluster, delivering 100kWh at 51.2V nominal and around 100A continuous. Each module carries its own slave BMS board that measures cell voltage and temperature and reports to the master BMS on the rear door. The master BMS balances cells, estimates state of charge and state of health, and communicates with the PCS over CAN. The cabinet includes a manual DC disconnect, a maintenance bypass, and a pre-charge contactor to protect the PCS DC bus on startup. A built-in gas detection and aerosol fire suppression module gives early warning and a first line of defense before the building fire system arrives.
Technical Specifications
Nominal energy 100kWh, nominal voltage 51.2V, usable energy 90 percent. Chemistry LFP, cycle life 6000 cycles to 80 percent depth of discharge at 25 degrees Celsius. Continuous charge and discharge current 100A, peak 200A for 30 seconds. Operating temperature charge 0 to 50 degrees Celsius, discharge minus 20 to 55 degrees Celsius. Protection IP20 indoor. Communication CAN 2.0B, RS485 Modbus. Fire detection: smoke, gas, and temperature sensors; aerosol suppression built in. Dimensions 800 x 800 x 2000 millimeters, weight 650 kilograms. Certifications IEC 62619, UL 1973, CE, UN 38.3. KITOZER five-year warranty or 6000 cycles.
Application Scenarios
The 100kWh cabinet pairs with a 50kW PCS to form a two-hour storage block for small commercial buildings, and can be paralleled with up to ten cabinets to reach 1MWh for larger factories. It is used for peak shaving at facilities with time-of-use tariffs, for backup power at clinics and data closets, and for self-consumption at rooftop PV sites where the array produces more than the daytime load. Integrators like the cabinet because it ships pre-tested, so on-site work is limited to lifting, leveling, and connecting the DC and communication cables.
Key Advantages
LFP chemistry delivers long cycle life and a wide thermal stability margin compared with NMC, which matters in indoor rooms where fire safety is a top priority. The integrated BMS, fire detection, and suppression remove the need for the integrator to source and wire those components separately, reducing commissioning time and risk. The 51.2V nominal voltage is safe for installers and avoids the high-voltage qualification needed for larger racks. Up to ten cabinets can parallel on one PCS bus, so a site can start at 100kWh and scale to 1MWh without replacing hardware.
Installation and Maintenance
Place the cabinet on a level concrete floor with at least 50 millimeters of clearance at the rear for cable bending, and keep ambient temperature between 20 and 30 degrees Celsius for best cycle life. Connect the battery to the PCS with the cross-section recommended in the installation manual, and verify the CAN bus termination resistor is fitted at the end of the daisy chain. Commissioning includes a cell voltage balance check, a capacity test, and a communication handshake with the PCS. Quarterly inspections include cleaning the air filter, reading the BMS state-of-health trend, and checking that no cell has drifted more than 50 millivolts from the pack average. Keep the cabinet door closed and locked when not in service.
Price
From $11,800 per cabinet. Contact KITOZER for bundled PCS and cabinet pricing, and for shipping to project sites.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com