The KITOZER 100kWh lithium iron phosphate battery cabinet is a floor-standing energy storage unit for commercial peak shaving, solar self-consumption, and backup power. It combines high-density LFP modules, a master and slave BMS, liquid or forced-air thermal management, and DC protection in a single cabinet that pairs with a 50kW or 100kW PCS. The unit is engineered for multi-shift operation in factories, offices, and retail buildings, and it can be paralleled to form multi-megawatt installations.
Table of Contents
ToggleProduct Overview
The cabinet stacks two 50kWh LFP battery clusters, each with its own slave BMS and a master BMS that coordinates the clusters and communicates with the PCS. The thermal management system maintains cell temperature within a 5-degree Celsius band, reducing degradation and extending cycle life. A built-in DC main breaker, pre-charge resistor, and fuse protect the battery string from faults. Smoke and gas detection connect to the site fire alarm panel.
The cabinet uses a high-voltage DC bus above 600V, which lowers current for a given power and reduces cable cross-section. Each cluster has its own contactor and fuse, so a fault in one cluster can be isolated without shutting down the whole cabinet. The front door houses a 7-inch HMI that shows state of charge, cluster voltage, current, and alarm history. The rear door gives access to the DC terminals and the thermal management unit.
Technical Specifications
Rated energy 100kWh, usable 95kWh. Nominal voltage 614V DC, range 540 to 672V. Continuous charge and discharge 100A, peak 150A for 30 seconds. Round-trip efficiency more than 95 percent. Cycle life 8000 cycles at 80 percent DOD. LFP chemistry. Communication CAN to PCS, Modbus TCP to EMS. Protection IP20, optional IP55 outdoor. Operating temperature charge 0 to 50 degrees Celsius. Dimensions 1200x1000x2000mm, weight 980kg. Certifications CE, IEC 62619, IEC 62040, UN38.3. KITOZER brand, 5-year warranty or 8000 cycles.
Applications
This cabinet is used in C&I peak shaving systems, combined PV plus storage at factories and shopping malls, and critical load backup at small data centers and hospitals. It can also be paralleled up to 10 cabinets to form a 1MWh cluster behind a 500kW PCS for larger grid services or microgrid applications. In cold climates, the heater option allows charging down to -20 degrees Celsius.
Advantages and Features
Active balancing across cells and clusters minimizes capacity fade and prolongs pack life. The thermal management system ensures uniform cell temperatures, reducing the risk of early outlier cell failures. A high-voltage DC bus lowers current for the same power, reducing cable cost and losses. The cabinet supports remote firmware upgrade and state of health reporting to the cloud EMS. Mechanical design allows forklift and crane handling with integrated lifting eyes.
The cabinet includes a module-level fire detection and gas exhaust path, and an optional module-level aerosol suppression system. The master BMS supports dual redundant CAN communication to the PCS, improving reliability. The HMI displays a cell voltage heat map, so maintenance staff can identify a weak cluster early. The cabinet can be transported with about 30 percent state of charge, and the shipping weight complies with standard road freight limits.
Installation and Maintenance
Install on a level concrete plinth in a dedicated battery room with fire-rated walls and independent ventilation. Maintain 1000mm front clearance and 800mm rear clearance. Use shielded DC cables rated for 1000V, torque per connector specification, and connect the protective earth to the cabinet bonding bar. Commissioning includes cell voltage spread check, insulation resistance, and a simulated fault test of the BMS trip outputs.
Maintenance quarterly includes thermal imaging of connectors, annual includes fan and coolant check, and every two years include contactor inspection. Keep the room temperature between 20 and 25 degrees Celsius for maximum service life. Store spare modules in a dry area at 50 percent state of charge. The BMS logs the last 1000 events with timestamp, which helps diagnose gradual degradation. If a module replacement is needed, KITOZER ships a matched module with state of charge and state of health calibrated to the existing pack.
Price
From $11,800/cabinet. Contact +86 13922289957 for 100kWh storage system pricing and multi-cabinet cluster design.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com