KITOZER 10kV/35kV High-Voltage Power Distribution Module Solution

Table of Contents

1. System Overview

The KITOZER 10kV/35kV high-voltage power distribution module is a core medium & high-voltage power distribution device integrating power distribution, control, protection and monitoring. It adapts to traditional power grids and new energy step-up scenarios including photovoltaic power, wind power and energy storage, featuring high reliability, intelligence, modular design and easy operation & maintenance.

Adopting a fully enclosed metal-clad structure and strictly complying with GB 3906 and IEC 62271 standards, the system can operate stably under ambient temperatures ranging from -40℃ to +55℃ and at altitudes up to 3000m. It realizes safe power transmission, rapid fault isolation and remote data monitoring, and is widely applied in industrial parks, new energy power stations, rail transit, data centers and other scenarios.

10kV/35kV High-Voltage Distribution Modules

2. System Composition

The system consists of four interlinked subsystems: primary main circuit equipment, secondary control & protection equipment, intelligent monitoring equipment and auxiliary systems. Each module operates independently while coordinating with others to ensure system safety and reliability.

  1. Primary Main Circuit Equipment: Vacuum circuit breakers, disconnectors, earthing switches, current transformers (CT), voltage transformers (PT), zinc oxide surge arresters, main busbars, cable accessories, high-voltage cables.
  2. Secondary Control & Protection Equipment: Microcomputer protection devices, intelligent measurement & control devices, fault recording devices, electric energy metering devices, control switches, signal indicator lights, secondary circuit cables.
  3. Intelligent Monitoring Equipment: Wireless temperature sensors, partial discharge monitors, temperature & humidity sensors, smoke/temperature detectors, intelligent gateways, monitoring hosts.
  4. Auxiliary Systems: Cabinet lighting, heating & dehumidification devices, five-prevention interlock devices, earthing systems, ventilation & heat dissipation devices, fire alarm devices.

3. System Classification

CAD Drawings of High-Voltage Distribution System

3.1 Classification by Voltage Level

  • 10kV High-Voltage Distribution Module: Matches 10kV nominal voltage systems, with rated insulation levels of 42kV/1min (power frequency) and 75kV (lightning impulse). Applied to the front end of medium & low-voltage power distribution, grid connection of distributed photovoltaic/wind power, and user substations for industrial & commercial facilities.
  • 35kV High-Voltage Distribution Module: Matches 35kV nominal voltage systems, with rated insulation levels of 95kV/1min (power frequency) and 185kV (lightning impulse). Used for step-up stations of large-scale new energy power plants, regional substations and main power distribution stations of industrial enterprises.

3.2 Classification by Structural Form

  • Metal-Clad Withdrawable Switchgear (KYN Series): Middle-mounted structure with removable circuit breakers for convenient maintenance, IP4X protection grade, suitable for mainstream 10kV/35kV scenarios.
  • SF6 Gas-Insulated Switchgear: Fully sealed SF6 gas insulation, compact size and maintenance-free design. Ideal for confined spaces, high-humidity and high-pollution environments such as underground substations and offshore wind farms.
  • Ring Main Unit (HXGN Series): Compact design combining load switches and fuses, low cost and simple operation, applied to distribution network branches and small-scale photovoltaic power stations.
  • Prefabricated Box-Type Substation: Integrated prefabricated cabin combining high-voltage units, transformers and low-voltage equipment. Factory pre-assembled for rapid on-site installation, suitable for new energy power stations and outdoor construction sites.

Production Workshop of High-Voltage Distribution Equipment

3.3 Classification by Function & Application

  • Incoming Cabinet: Receives power from upper-level grids, equipped with circuit breakers, CT, PT and protection devices for power access and main circuit protection.
  • Outgoing Cabinet: Supplies power to downstream loads, fitted with circuit breakers, CT and protection devices to realize circuit control and fault protection.
  • PT Cabinet: Installs voltage transformers to provide measurement, protection and synchronizing voltage signals, equipped with surge arresters and fuses.
  • Metering Cabinet: Configures high-precision CT/PT and electric energy meters for power metering, meeting settlement requirements of power supply authorities.
  • Bus Coupler Cabinet: Connects double busbars or sectionalized busbars with circuit breakers to enable power switching and load transfer, improving power supply reliability.
  • Capacitor Compensation Cabinet: Equipped with high-voltage capacitors, reactors and discharge coils to compensate reactive power and boost power factor.
  • Station Service Transformer Cabinet: Fitted with dry-type transformers to supply low-voltage power for station lighting, control and monitoring equipment.

4. System Schematic Diagrams

4.1 10kV Single Busbar Sectionalized Wiring Schematic

  • Two 10kV incoming lines with single sectionalized busbars connected by a bus coupler cabinet;
  • Each bus section is equipped with incoming cabinet, PT cabinet, metering cabinet, outgoing cabinet and capacitor compensation cabinet;
  • Electrical interlock between incoming cabinets and bus coupler cabinet to prevent parallel operation;
  • Microcomputer protection devices deployed to implement overcurrent, instantaneous overcurrent, earth fault and overvoltage protection.

4.2 35kV Single Busbar Wiring Schematic

  • Single 35kV incoming line with single busbar wiring, suitable for small & medium-sized new energy power stations;
  • Configured with incoming cabinet, PT cabinet, metering cabinet, outgoing cabinet and station service transformer cabinet;
  • Vacuum circuit breakers and SF6 surge arresters adopted, with insulation levels meeting 35kV standards;
  • Intelligent monitoring system collects real-time data including voltage, current, temperature and partial discharge.

35kV High-Voltage Distribution Installation Site

5. Full System Configuration List (Basic / Standard / Premium, Brand: KITOZER)

5.1 10kV High-Voltage Distribution Module Configuration List

5.1.1 Basic Solution (Economical, for Small Industrial & Commercial Facilities, Distributed PV)

表格

No.Product NameModel & SpecificationTechnical ParametersQtyUnitBrandRemarks
1Metal-Clad Withdrawable SwitchgearKITOZER-KYN28-12Rated voltage 12kV, rated current 630A, short-circuit breaking current 20kA, IP4X protection grade5SetKITOZER1 incoming, 2 outgoing, 1 PT, 1 metering cabinet
2Vacuum Circuit BreakerKITOZER-VS1-12/630Rated voltage 12kV, rated current 630A, short-circuit breaking current 20kA, mechanical life 10,000 operations3SetKITOZERDeployed in incoming & outgoing cabinets
3DisconnectorKITOZER-GN22-12/630Rated voltage 12kV, rated current 630A, short-time withstand current 20kA/4s2SetKITOZERInstalled in incoming cabinets
4Earthing SwitchKITOZER-JN15-12/20Rated voltage 12kV, short-time withstand current 20kA/4s3SetKITOZERFitted for all cabinets
5Current TransformerKITOZER-LZZBJ9-12Rated voltage 12kV, ratio 200/5A, accuracy class 0.5S/10P105SetKITOZERFor measurement & protection
6Voltage TransformerKITOZER-JDZJ-12Rated voltage 12kV, ratio 10/0.1kV, accuracy class 0.52SetKITOZERInstalled in PT cabinet
7Zinc Oxide Surge ArresterKITOZER-YH5WZ-17/45Rated voltage 17kV, residual voltage ≤45kV, discharge current 40kA2SetKITOZERFitted in PT & incoming cabinets
8Microcomputer Protection DeviceKITOZER-AM5SE-F10kV line protection, overcurrent/instantaneous/earth fault protection, RS485 communication3SetKITOZERDeployed in incoming & outgoing cabinets
9Intelligent Measurement & Control DeviceKITOZER-ASD200Temperature & humidity monitoring, switch status indication, remote control5SetKITOZERFitted for all cabinets
10Heating & Dehumidification DeviceKITOZER-CS-100Power 100W, auto-start when humidity ≥60%5SetKITOZERFitted for all cabinets
11Five-Prevention Interlock DeviceKITOZER-WF-12Mechanical interlock, prevents erroneous switching & live earthing5SetKITOZERFitted for all cabinets
12High-Voltage CableYJV22-8.7/10kV-3×9510kV cross-linked polyethylene insulated copper cable 3×95mm²50MeterKITOZERFor incoming & outgoing connections

5.1.2 Standard Solution (Standard Grade, for Industrial Parks, Medium-Sized PV/Wind Power Stations)

表格

No.Product NameModel & SpecificationTechnical ParametersQtyUnitBrandRemarks
1Metal-Clad Withdrawable SwitchgearKITOZER-KYN28-12Rated voltage 12kV, rated current 1250A, short-circuit breaking current 31.5kA, IP4X protection grade8SetKITOZER2 incoming, 3 outgoing, 1 PT, 1 metering, 1 bus coupler cabinet
2Vacuum Circuit BreakerKITOZER-VS1-12/1250Rated voltage 12kV, rated current 1250A, short-circuit breaking current 31.5kA, mechanical life 20,000 operations5SetKITOZERDeployed in incoming, outgoing & bus coupler cabinets
3DisconnectorKITOZER-GN22-12/1250Rated voltage 12kV, rated current 1250A, short-time withstand current 31.5kA/4s3SetKITOZERInstalled in incoming cabinets
4Earthing SwitchKITOZER-JN15-12/31.5Rated voltage 12kV, short-time withstand current 31.5kA/4s5SetKITOZERFitted for all cabinets
5Current TransformerKITOZER-LZZBJ9-12Rated voltage 12kV, ratio 400/5A, accuracy class 0.2S/10P158SetKITOZERFor measurement & protection
6Voltage TransformerKITOZER-JDZJ-12Rated voltage 12kV, ratio 10/0.1kV, accuracy class 0.22SetKITOZERInstalled in PT cabinet
7Zinc Oxide Surge ArresterKITOZER-YH5WZ-17/45Rated voltage 17kV, residual voltage ≤45kV, discharge current 40kA3SetKITOZERFitted in PT & incoming cabinets
8Microcomputer Protection DeviceKITOZER-AM5SE-T10kV transformer/line protection, overcurrent/instantaneous/earth/overvoltage protection, Ethernet communication5SetKITOZERDeployed in incoming, outgoing & bus coupler cabinets
9Intelligent Measurement & Control DeviceKITOZER-ASD300Temp/humidity/partial discharge monitoring, switch status, remote control & data upload8SetKITOZERFitted for all cabinets
10Wireless Temperature SensorKITOZER-WT-100Measuring range -40℃~125℃, wireless transmission, accuracy ±0.5℃24PieceKITOZERFor circuit breaker contacts & busbar joints
11Heating & Dehumidification DeviceKITOZER-CS-200Power 200W, auto-start at humidity ≥60%, with communication function8SetKITOZERFitted for all cabinets
12Five-Prevention Interlock DeviceKITOZER-WF-12Mechanical + electrical interlock, anti-misoperation with intelligent alert8SetKITOZERFitted for all cabinets
13High-Voltage CapacitorKITOZER-BWF10.5-100-1WRated voltage 10.5kV, capacity 100kvar, single-phase3SetKITOZERInstalled in capacitor compensation cabinet
14Series ReactorKITOZER-CKSC-10-6%Rated voltage 10kV, reactance rate 6%, harmonic suppression1SetKITOZERInstalled in capacitor compensation cabinet
15High-Voltage CableYJV22-8.7/10kV-3×18510kV cross-linked polyethylene insulated copper cable 3×185mm²80MeterKITOZERFor incoming & outgoing connections

5.1.3 Premium Solution (Intelligent Grade, for Data Centers, Large-Scale New Energy Power Stations)

表格

No.Product NameModel & SpecificationTechnical ParametersQtyUnitBrandRemarks
1Metal-Clad Withdrawable SwitchgearKITOZER-KYN28-12Rated voltage 12kV, rated current 2500A, short-circuit breaking current 40kA, IP54 protection grade12SetKITOZER2 incoming, 5 outgoing, 1 PT, 1 metering, 1 bus coupler, 1 capacitor cabinet
2Vacuum Circuit BreakerKITOZER-VS1-12/2500Rated voltage 12kV, rated current 2500A, short-circuit breaking current 40kA, mechanical life 30,000 operations7SetKITOZERDeployed in incoming, outgoing & bus coupler cabinets
3DisconnectorKITOZER-GN22-12/2500Rated voltage 12kV, rated current 2500A, short-time withstand current 40kA/4s4SetKITOZERInstalled in incoming cabinets
4Earthing SwitchKITOZER-JN15-12/40Rated voltage 12kV, short-time withstand current 40kA/4s7SetKITOZERFitted for all cabinets
5Current TransformerKITOZER-LZZBJ9-12Rated voltage 12kV, ratio 630/5A, accuracy class 0.2S/5P2012SetKITOZERFor measurement & protection
6Voltage TransformerKITOZER-JDZJ-12Rated voltage 12kV, ratio 10/0.1kV, accuracy class 0.12SetKITOZERInstalled in PT cabinet
7Zinc Oxide Surge ArresterKITOZER-YH5WZ-17/45Rated voltage 17kV, residual voltage ≤45kV, discharge current 60kA4SetKITOZERFitted in PT & incoming cabinets
8Microcomputer Protection DeviceKITOZER-AM5SE-IMU10kV intelligent protection, differential/overcurrent/instantaneous/earth/overvoltage/under-frequency protection, dual Ethernet communication7SetKITOZERDeployed in incoming, outgoing & bus coupler cabinets
9Intelligent Measurement & Control DeviceKITOZER-ASD500Temp/humidity/partial discharge/vibration monitoring, switch status, remote control & edge computing12SetKITOZERFitted for all cabinets
10Wireless Temperature SensorKITOZER-WT-200Measuring range -50℃~150℃, wireless transmission, accuracy ±0.3℃ with alarm function36PieceKITOZERFor circuit breaker contacts, busbars & cable terminals
11Partial Discharge MonitorKITOZER-PD-100Monitoring frequency 10kHz~100MHz, sensitivity ≤5pC, online monitoring12SetKITOZERFitted for all cabinets
12Heating & Dehumidification DeviceKITOZER-CS-300Power 300W, auto-start at humidity ≥55%, intelligent constant temperature with communication12SetKITOZERFitted for all cabinets
13Five-Prevention Interlock DeviceKITOZER-WF-12Mechanical + electrical + software interlock, remote anti-misoperation & intelligent early warning12SetKITOZERFitted for all cabinets
14High-Voltage CapacitorKITOZER-BWF10.5-200-1WRated voltage 10.5kV, capacity 200kvar, single-phase3SetKITOZERInstalled in capacitor compensation cabinet
15Series ReactorKITOZER-CKSC-10-6%Rated voltage 10kV, reactance rate 6%, harmonic suppression with temperature control1SetKITOZERInstalled in capacitor compensation cabinet
16Intelligent GatewayKITOZER-GW-500Supports Modbus/TCP & IEC61850 protocols, encrypted data upload2SetKITOZERSystem data aggregation
17Monitoring HostKITOZER-SC-1000Industrial-grade, quad-core processor, 500G hard disk, 19-inch touch screen1SetKITOZERSystem monitoring & management
18High-Voltage CableYJV22-8.7/10kV-3×30010kV cross-linked polyethylene insulated copper cable 3×300mm²100MeterKITOZERFor incoming & outgoing connections

5.2 35kV High-Voltage Distribution Module Configuration List

5.2.1 Basic Solution (Economical, for Small Wind Farms & Distributed PV)

表格

No.Product NameModel & SpecificationTechnical ParametersQtyUnitBrandRemarks
1Metal-Clad Withdrawable SwitchgearKITOZER-KYN61-40.5Rated voltage 40.5kV, rated current 630A, short-circuit breaking current 25kA, IP4X protection grade4SetKITOZER1 incoming, 2 outgoing, 1 PT cabinet
2Vacuum Circuit BreakerKITOZER-VS1-40.5/630Rated voltage 40.5kV, rated current 630A, short-circuit breaking current 25kA, mechanical life 10,000 operations3SetKITOZERDeployed in incoming & outgoing cabinets
3DisconnectorKITOZER-GN22-40.5/630Rated voltage 40.5kV, rated current 630A, short-time withstand current 25kA/4s2SetKITOZERInstalled in incoming cabinets
4Earthing SwitchKITOZER-JN15-40.5/25Rated voltage 40.5kV, short-time withstand current 25kA/4s3SetKITOZERFitted for all cabinets
5Current TransformerKITOZER-LZZBJ9-40.5Rated voltage 40.5kV, ratio 200/5A, accuracy class 0.5S/10P104SetKITOZERFor measurement & protection
6Voltage TransformerKITOZER-JDZJ-40.5Rated voltage 40.5kV, ratio 35/0.1kV, accuracy class 0.51SetKITOZERInstalled in PT cabinet
7Zinc Oxide Surge ArresterKITOZER-YH5WZ-42/134Rated voltage 42kV, residual voltage ≤134kV, discharge current 40kA2SetKITOZERFitted in PT & incoming cabinets
8Microcomputer Protection DeviceKITOZER-AM5SE-F35kV line protection, overcurrent/instantaneous/earth fault protection, RS485 communication3SetKITOZERDeployed in incoming & outgoing cabinets
9Intelligent Measurement & Control DeviceKITOZER-ASD200Temperature & humidity monitoring, switch status indication, remote control4SetKITOZERFitted for all cabinets
10Heating & Dehumidification DeviceKITOZER-CS-200Power 200W, auto-start when humidity ≥60%4SetKITOZERFitted for all cabinets
11Five-Prevention Interlock DeviceKITOZER-WF-40.5Mechanical interlock, prevents erroneous switching & live earthing4SetKITOZERFitted for all cabinets
12High-Voltage CableYJV22-26/35kV-3×9535kV cross-linked polyethylene insulated copper cable 3×95mm²50MeterKITOZERFor incoming & outgoing connections

5.2.2 Standard Solution (Standard Grade, for Medium-Sized New Energy Power Stations & Industrial Enterprises)

表格

No.Product NameModel & SpecificationTechnical ParametersQtyUnitBrandRemarks
1Metal-Clad Withdrawable SwitchgearKITOZER-KYN61-40.5Rated voltage 40.5kV, rated current 1250A, short-circuit breaking current 31.5kA, IP4X protection grade6SetKITOZER2 incoming, 2 outgoing, 1 PT, 1 metering cabinet
2Vacuum Circuit BreakerKITOZER-VS1-40.5/1250Rated voltage 40.5kV, rated current 1250A, short-circuit breaking current 31.5kA, mechanical life 20,000 operations4SetKITOZERDeployed in incoming & outgoing cabinets
3DisconnectorKITOZER-GN22-40.5/1250Rated voltage 40.5kV, rated current 1250A, short-time withstand current 31.5kA/4s3SetKITOZERInstalled in incoming cabinets
4Earthing SwitchKITOZER-JN15-40.5/31.5Rated voltage 40.5kV, short-time withstand current 31.5kA/4s4SetKITOZERFitted for all cabinets
5Current TransformerKITOZER-LZZBJ9-40.5Rated voltage 40.5kV, ratio 400/5A, accuracy class 0.2S/10P156SetKITOZERFor measurement & protection
6Voltage TransformerKITOZER-JDZJ-40.5Rated voltage 40.5kV, ratio 35/0.1kV, accuracy class 0.21SetKITOZERInstalled in PT cabinet
7Zinc Oxide Surge ArresterKITOZER-YH5WZ-42/134Rated voltage 42kV, residual voltage ≤134kV, discharge current 40kA3SetKITOZERFitted in PT & incoming cabinets
8Microcomputer Protection DeviceKITOZER-AM5SE-T35kV transformer/line protection, overcurrent/instantaneous/earth/overvoltage protection, Ethernet communication4SetKITOZERDeployed in incoming & outgoing cabinets
9Intelligent Measurement & Control DeviceKITOZER-ASD300Temp/humidity/partial discharge monitoring, switch status, remote control & data upload6SetKITOZERFitted for all cabinets
10Wireless Temperature SensorKITOZER-WT-100Measuring range -40℃~125℃, wireless transmission, accuracy ±0.5℃18PieceKITOZERFor circuit breaker contacts & busbar joints
11Heating & Dehumidification DeviceKITOZER-CS-300Power 300W, auto-start at humidity ≥60%, with communication function6SetKITOZERFitted for all cabinets
12Five-Prevention Interlock DeviceKITOZER-WF-40.5Mechanical + electrical interlock, anti-misoperation with intelligent alert6SetKITOZERFitted for all cabinets
13High-Voltage CableYJV22-26/35kV-3×18535kV cross-linked polyethylene insulated copper cable 3×185mm²80MeterKITOZERFor incoming & outgoing connectionsZZZZZZZZZZ
  • Rated Voltage: 12kV / 40.5kV
  • Voltage Ratio: 10/0.1kV, 35/0.1kV
  • Accuracy Class: Class 0.5 (basic) / Class 0.2 (standard) / Class 0.1 (premium)
  • Power Frequency Withstand Voltage: 10kV: 42kV/1min; 35kV: 95kV/1min
  • Lightning Impulse Withstand Voltage: 10kV: 75kV; 35kV: 185kV

6.5 Zinc Oxide Surge Arrester (YH5WZ-17/45 / YH5WZ-42/134)

  • Rated Voltage: 17kV (10kV system) / 42kV (35kV system)
  • Continuous Operating Voltage: 13.6kV / 34kV
  • Lightning Impulse Residual Voltage: ≤45kV (10kV) / ≤134kV (35kV)
  • Nominal Discharge Current: 40kA (standard) / 60kA (premium)
  • Leakage Current: ≤50μA under operating voltage

6.6 Microcomputer Protection Device (AM5SE-F / AM5SE-T / AM5SE-IMU)

  • Operating Voltage: DC220V / DC110V
  • Protection Functions: Overcurrent, instantaneous overcurrent, earth fault, overvoltage, undervoltage, underfrequency, differential protection (premium only)
  • Communication Interface: RS485 (basic) / Ethernet (standard & premium) / Dual Ethernet (premium)
  • Measurement Accuracy: Current ≤±0.5%, Voltage ≤±0.5%
  • Operating Time: Instantaneous trip ≤0.04s, Overcurrent trip ≤0.1s

6.7 Wireless Temperature Sensor (WT-100 / WT-200)

  • Measuring Range: -40℃~125℃ (basic) / -50℃~150℃ (premium)
  • Measurement Accuracy: ±0.5℃ (basic) / ±0.3℃ (premium)
  • Wireless Transmission Distance: ≤50m
  • Operating Power Supply: DC3.6V battery, service life ≥5 years
  • Protection Grade: IP67

6.8 Partial Discharge Monitor (PD-100 / PD-200)

  • Monitoring Frequency Band: 10kHz ~ 100MHz
  • Detection Sensitivity: ≤5pC
  • Monitoring Mode: Real-time online monitoring
  • Communication Interface: Ethernet
  • Adjustable Alarm Threshold (default: 10pC)

7. Product Application Scope

7.1 10kV High-Voltage Distribution Module

  • New Energy Industry: Distributed photovoltaic power stations, decentralized wind farms, energy storage station power distribution
  • Industrial & Commercial Sector: Industrial parks, data centers, commercial complexes, hospitals, schools, hotels
  • Infrastructure: Rail transit (metro, light rail), airports, ports, municipal engineering
  • Other Fields: Small hydropower stations, oil fields, mines, residential communities

7.2 35kV High-Voltage Distribution Module

  • New Energy Industry: Large-scale photovoltaic power stations, wind farms, centralized energy storage step-up stations
  • Heavy Industry: Large manufacturing plants, steel, chemical and metallurgical enterprises main distribution substations
  • Power Grid Sector: Regional substations, urban distribution network hubs, high-voltage transmission nodes
  • Other Fields: Large data centers, main rail transit substations, special industries (military, scientific research)

8. Product Advantages

8.1 Core Functional Features

  1. High Reliability: Fully enclosed metal-clad structure with IP4X~IP54 protection against dust, moisture and corrosion; vacuum circuit breakers deliver superior arc extinction performance with long mechanical service life and low failure rate; core components adopt top-tier domestic & international brands with strict quality inspection for stable operation.
  2. Intelligent Operation: Standard intelligent measurement & control devices monitor real-time voltage, current, temperature and partial discharge data; standard & premium models integrate wireless temperature sensing, partial discharge monitoring and edge computing modules to support remote monitoring, fault early warning and intelligent operation & maintenance; compatible with IEC61850, Modbus and other communication protocols for integration with smart energy management platforms.
  3. Superior Safety: Complete five-prevention interlock system with mechanical, electrical and software interlocks to eliminate misoperation risks; multi-layer protection (overcurrent, instantaneous overcurrent, earth fault, overvoltage) enables rapid fault isolation to protect equipment and personnel; reliable earthing system and surge arresters suppress overvoltage to prevent lightning damage.
  4. Modular Design: Independent functional units with compact layout to reduce floor space; factory pre-assembly allows fast on-site installation to shorten construction periods; easy maintenance with rapid replacement of faulty modules to cut operation costs.
  5. Eco-Friendly & Energy-Saving: Vacuum arc extinction eliminates SF6 leakage risks for green operation; high-efficiency components reduce power loss and energy consumption; low noise operation (≤55dB), suitable for urban and residential environments.

8.2 Customized Services

  • Voltage Customization: Custom 10kV, 35kV and non-standard voltage solutions (e.g. 20kV)
  • Capacity Customization: Rated current ranging from 630A to 4000A, short-circuit breaking current from 20kA to 50kA to match diverse load demands
  • Structural Customization: Custom metal-clad, gas-insulated, ring main unit and box-type substation designs for indoor, outdoor and confined-space scenarios
  • Function Customization: Optional harmonic control, reactive power compensation, energy storage grid connection and dual power switching modules
  • Appearance Customization: Custom cabinet color and dimensions to match site environment and architectural style

8.3 OEM & ODM Manufacturing Service

  • Full OEM/ODM support, customized production per client brand, technical specifications and drawings
  • Covered products: Full range of high-voltage switchgears, vacuum circuit breakers, transformers and protection devices
  • Production strictly follows KITOZER quality standards to guarantee consistent product reliability; assistance with product certifications including CCC, CQC, KEMA and CE

8.4 Confidentiality Service

  • Strict non-disclosure agreements to fully protect client technical drawings, parameters, solutions and order information
  • Dedicated production teams and independent workshops to avoid technical leakage; regular destruction of obsolete drawings and documents
  • Signable formal confidentiality contracts with clear liability clauses to safeguard client intellectual property and commercial interests

8.5 In-Stock Supply

  • Mass inventory of standard models (10kV KYN28-12, 35kV KYN61-40.5, 630A~1250A) for delivery within 3–7 days
  • Sufficient stock of core components (vacuum circuit breakers, transformers, protection devices) to guarantee on-time order fulfillment
  • Priority production for urgent orders; nationwide warehouses enable nearby delivery to shorten logistics cycles

8.6 Technical Parameter Superiority

  • High insulation performance: 10kV power frequency withstand voltage 42kV/1min, 35kV power frequency withstand voltage 95kV/1min, exceeding industrial standards for enhanced insulation safety
  • Strong short-circuit breaking capacity: Max 40kA withstand capability to absorb severe short-circuit faults and stabilize system operation
  • Extended mechanical service life: Premium vacuum circuit breakers support 30,000 mechanical operations to reduce maintenance frequency and costs
  • High monitoring precision: Wireless temperature measurement accuracy ±0.3℃, protection device current/voltage accuracy ±0.5% for accurate data acquisition

9. Tender Specification Parameters (★ Mandatory Index)

9.1 Metal-Clad Withdrawable Switchgear

  • ★ Rated Voltage: 12kV/40.5kV (nominal 10kV/35kV)
  • ★ Rated Current: ≥630A (basic) / ≥1250A (standard) / ≥2000A (premium)
  • ★ Rated Short-Circuit Breaking Current: ≥20kA (basic) / ≥31.5kA (standard) / ≥40kA (premium)
  • ★ Protection Grade: ≥IP4X (standard) / ≥IP54 (premium)
  • ★ Insulation Level: 10kV ≥42kV/1min power frequency withstand; 35kV ≥95kV/1min power frequency withstand
  • ★ Operating Temperature Range: -40℃ ~ +55℃

9.2 Vacuum Circuit Breaker

  • ★ Rated Voltage: 12kV/40.5kV
  • ★ Rated Current: ≥630A (basic) / ≥1250A (standard) / ≥2000A (premium)
  • ★ Rated Short-Circuit Breaking Current: ≥20kA (basic) / ≥31.5kA (standard) / ≥40kA (premium)
  • ★ Mechanical Life: ≥10,000 operations (basic) / ≥20,000 operations (standard) / ≥30,000 operations (premium)
  • ★ Opening Time ≤0.15s, Closing Time ≤0.2s

9.3 Current Transformer

  • ★ Rated Voltage: 12kV/40.5kV
  • ★ Accuracy Class: Measurement ≥0.5S; Protection ≥10P10 (basic) / ≥10P15 (standard) / ≥5P20 (premium)
  • ★ Power Frequency Withstand Voltage: 10kV ≥42kV/1min; 35kV ≥95kV/1min

9.4 Voltage Transformer

  • ★ Rated Voltage: 12kV/40.5kV
  • ★ Accuracy Class: ≥Class 0.5 (basic) / ≥Class 0.2 (standard) / ≥Class 0.1 (premium)
  • ★ Power Frequency Withstand Voltage: 10kV ≥42kV/1min; 35kV ≥95kV/1min

9.5 Zinc Oxide Surge Arrester

  • ★ Rated Voltage: 17kV (10kV system) / 42kV (35kV system)
  • ★ Lightning Impulse Residual Voltage: ≤45kV (10kV) / ≤134kV (35kV)
  • ★ Nominal Discharge Current ≥40kA

9.6 Microcomputer Protection Device

  • ★ Mandatory Protection Functions: Overcurrent, instantaneous overcurrent, earth fault and overvoltage protection
  • ★ Communication Interface ≥RS485 (basic) / ≥Ethernet (standard & premium)
  • ★ Instantaneous Trip Operating Time ≤0.04s

9.7 Wireless Temperature Sensor

  • ★ Measuring Range: -40℃~125℃ (basic) / -50℃~150℃ (premium)
  • ★ Measurement Accuracy ≤±0.5℃ (basic) / ≤±0.3℃ (premium)

10. Complete Product Solutions

10.1 10kV Industrial & Commercial Power Distribution Solution

  • Applicable Scenarios: Industrial parks, commercial complexes, data centers, hospitals and schools with load capacity from 500kVA to 5000kVA
  • System Configuration: KYN28-12 switchgear with single sectionalized busbars and dual incoming lines; 2 incoming cabinets, 3~5 outgoing cabinets, 1 PT cabinet, 1 metering cabinet, 1 bus coupler cabinet and 1 capacitor compensation cabinet; standard & premium models equipped with wireless temperature sensing, intelligent monitoring and remote operation & maintenance systems; microcomputer protection devices to realize overcurrent, instantaneous, earth and overvoltage protection; capacitor compensation cabinet to boost power factor above 0.95
  • Solution Advantages: High power supply reliability with dual power switching to avoid production interruption; intelligent monitoring enables real-time equipment status tracking and advance fault warning; modular design simplifies installation and maintenance to cut operation costs; eco-friendly low-loss and low-noise design suitable for industrial and commercial environments

10.2 35kV New Energy Power Station Step-Up Solution

  • Applicable Scenarios: Large-scale photovoltaic power stations (10MW~100MW), wind farms (20MW~200MW) and centralized energy storage stations with 35kV grid connection
  • System Configuration: KYN61-40.5 switchgear with single busbar or single sectionalized busbar wiring; 2 incoming cabinets, 4~6 outgoing cabinets, 1 PT cabinet, 1 metering cabinet, 1 bus coupler cabinet and 1 station service transformer cabinet; premium models integrate partial discharge monitoring, wireless temperature sensing and edge computing modules for smart energy platform access; differential, overcurrent, instantaneous and earth fault protection for full equipment safety; SCB14 Class 1 high-efficiency step-up transformers
  • Solution Advantages: High insulation level adapts to harsh outdoor environments with extreme temperature, humidity and sand dust; high short-circuit breaking capacity withstands impact currents from new energy grid connection; intelligent operation & maintenance supports remote monitoring, fault early warning and data analysis to improve station operation efficiency; customizable design matching different capacity and terrain requirements of new energy power plants

10.3 10kV/35kV Dual Power Switching Solution

  • Applicable Scenarios: Facilities demanding ultra-high power supply continuity including data centers, hospital operating rooms, precision manufacturing workshops and chemical enterprises with zero power outage tolerance
  • System Configuration: KYN28-12 for 10kV systems, KYN61-40.5 for 35kV systems; dual incoming lines with single sectionalized busbars connected by bus coupler cabinets; dual power fast switching device with switching time ≤20ms for seamless load transfer; mechanical + electrical interlocks between incoming and bus coupler cabinets to prevent parallel operation; intelligent monitoring tracks real-time voltage, frequency and phase of two power sources for automatic switching upon abnormal conditions; comprehensive protection isolates faults instantly to secure the standby power supply
  • Solution Advantages: Millisecond-level switching eliminates load perception of power loss; high-reliability interlocks prevent power parallel operation and fault escalation; flexible automatic & manual switching modes; compatible with both 10kV and 35kV voltage grades to meet high-reliability power supply standards

10.4 Prefabricated Box-Type Substation Solution

  • Applicable Scenarios: Outdoor new energy power stations, construction sites, temporary power supply, residential communities and municipal engineering requiring rapid installation and compact footprint
  • System Configuration: Integrated prefabricated cabin combining 10kV/35kV high-voltage switchgear, dry-type transformer and low-voltage distribution cabinet; high-voltage side adopts KYN28-12/KYN61-40.5 or gas-insulated switchgear, low-voltage side adopts MNS/GGD distribution cabinets; factory pre-assembly and commissioning, only foundation construction and cable connection required on-site; intelligent monitoring system for remote status tracking of high-voltage, transformer and low-voltage equipment; IP54 outdoor protection for stable operation under all weather conditions
  • Solution Advantages: Factory prefabrication cuts on-site construction period by over 50%; integrated design reduces land occupation and site costs; outdoor dustproof, moisture-proof and anti-corrosion protection for harsh environments; intelligent remote monitoring enables unattended operation and lower maintenance costs

11. Product Application Cases

11.1 35kV Large-Scale PV Power Station Project (100MW PV Power Station in Inner Mongolia)

  • Project Overview: 100MW centralized photovoltaic power station stepping up to 35kV for grid connection, located in desert with extreme temperature swings and heavy sand dust
  • Product Configuration: 12 sets of KITOZER 35kV KYN61-40.5 premium switchgears (2 incoming, 6 outgoing, 1 PT, 1 metering, 1 bus coupler, 1 station service transformer cabinet); 6 VS1-40.5/2000 vacuum circuit breakers; 6 AM5SE-IMU microcomputer protection devices; 30 wireless temperature sensors; 10 partial discharge monitors; 2 SCB14-5000/35 step-up transformers
  • Project Outcomes: Stable operation for 2 years without major breakdowns; intelligent monitoring system issued 5 early warnings for overheating and partial discharge risks to avoid equipment failures; reliable performance in desert dust, humidity and extreme temperature conditions; power generation efficiency increased by 3%, operation & maintenance costs reduced by 40%

11.2 10kV Data Center Power Distribution Project (Large-Scale Data Center in Guangzhou)

12. Common Product Faults & Maintenance Guidelines

12.1 Common Faults & Troubleshooting Methods

12.1.1 Vacuum Circuit Breaker Faults

  1. Failure to Open / Close
    • Phenomenon: No movement or incomplete stroke after operation command transmission
    • Root Causes: Loss of control power supply, incomplete energy storage of operating mechanism, jamming of transmission components, poor contact of auxiliary switches, unlocked five-prevention interlock
    • Solutions: Inspect DC220V±10% control loop power; conduct manual energy storage and check energy storage mechanism; clean debris and lubricate transmission parts; replace damaged auxiliary switches; release five-prevention interlock restraints
  2. Abnormal Noise & Vibration During Switching
    • Phenomenon: Loud abnormal sounds and intense vibration on opening/closing
    • Root Causes: Insufficient mechanism lubrication, loose connecting rods, worn contacts, damaged arc extinguishing chamber
    • Solutions: Lubricate transmission components; tighten connecting rod bolts; inspect contact wear and replace severely worn parts; test arc extinguishing chamber and replace if air leakage or damage detected
  3. Overheating (High Contact Temperature)
    • Phenomenon: Wireless temperature alarm triggered, contact temperature exceeding 80℃
    • Root Causes: Poor contact between contacts, loose connecting bolts, oxidized contact surfaces, long-term overload operation
    • Solutions: Cut off power to clean oxide layers on contacts; fasten all connecting bolts; adjust contact pressure; reduce load to avoid continuous overload

12.1.2 Switchgear Faults

  1. Internal Discharge Noise & Burnt Odor
    • Phenomenon: Continuous discharge sound and burnt smell inside cabinet, potential protective tripping
    • Root Causes: Damp/aged/damaged insulation components, accumulated dust on busbars, loose wiring terminals, excessive partial discharge
    • Solutions: Immediately cut power, conduct voltage testing and install earthing wires; clean dust and moisture inside cabinet; replace cracked insulation parts; fasten loose terminals; perform partial discharge testing and rectify over-limit defects
  2. Abnormal Cabinet Temperature & Humidity (Excessive Dampness / Overheating)
    • Phenomenon: Cabinet humidity ≥70% or temperature ≥40℃, heating/dehumidification or ventilation devices non-functional
    • Root Causes: Faulty heating & dehumidification unit, blocked ventilation channels, extreme ambient temperature/humidity
    • Solutions: Inspect power supply and heating elements of dehumidifier, replace defective units; clear ventilation blockages to guarantee heat dissipation; install auxiliary air conditioning or dehumidifiers to improve site environment
  3. Malfunction of Five-Prevention Interlock
    • Phenomenon: Unable to complete opening/closing operation due to interlock jamming
    • Root Causes: Rust on interlock mechanism, debris blockage, misaligned interlock positions
    • Solutions: Clean and derust interlock components with lubrication; adjust interlock positioning; replace damaged interlock assemblies

12.1.3 Transformer Faults

  1. Current Transformer Open Circuit
    • Phenomenon: Extremely high secondary voltage with discharge sound, accidental protective tripping
    • Root Causes: Loose secondary wiring, broken cables, poor terminal contact
    • Solutions: Cut power supply immediately (never open CT secondary under load); inspect secondary circuit, fasten loose terminals and replace broken wires; conduct insulation testing before power restoration
  2. Voltage Transformer Short Circuit
    • Phenomenon: Primary fuse blown, abnormal voltage readings, accidental protective tripping
    • Root Causes: Inter-turn winding short circuit, insulation breakdown, secondary short circuit fault
    • Solutions: Cut power to test winding insulation; replace defective voltage transformer; eliminate secondary short circuit faults and replace blown fuses

12.1.4 Protection Device Faults

  1. Unnecessary Tripping / Failure to Trip During Faults
    • Phenomenon: Circuit breaker trips without fault condition, or fails to trip under actual system faults
    • Root Causes: Incorrect protection setting values, miswired secondary circuits, defective devices, excessive CT/PT measurement error
    • Solutions: Verify and reset protection setting values; inspect and correct secondary wiring; test protection devices and replace faulty units; calibrate CT/PT and replace units with over-limit errors
  2. Communication Disconnection
    • Phenomenon: No real-time data uploaded to monitoring platform, device offline alert
    • Root Causes: Loose network cables, damaged crystal connectors, faulty gateway, incorrect network configuration
    • Solutions: Reconnect or replace network cables and crystal heads; restart gateway and replace defective units if needed; verify and reconfigure network parameters

12.2 Scheduled Maintenance Plan

12.2.1 Daily Routine Inspection

  • Check cabinet exterior for deformation, rust and damage, confirm tight cabinet door closure
  • Verify normal voltage/current readings and correct indicator light status
  • Listen for abnormal discharge noise or vibration inside cabinets
  • Monitor cabinet temperature (-5℃~40℃) and humidity (≤60%), confirm normal operation of dehumidification/ventilation devices
  • Review wireless temperature data to ensure contact temperature ≤70℃ with no active alarms

12.2.2 Weekly Maintenance

  • Wipe cabinet surfaces, operation panels and meters to remove dust and oil stains
  • Confirm correct opening/closing position indicators of circuit breakers, disconnectors and earthing switches
  • Inspect heating & dehumidification and ventilation systems for normal operation
  • Test five-prevention interlock for flexible, jamming-free movement

12.2.3 Monthly Maintenance

  • Tighten all wiring terminals on circuit breakers, transformers, busbars and cable joints to prevent loose connections
  • Inspect insulators and bushing sleeves for cracks, damage and dust accumulation
  • Lubricate transmission parts (connecting rods, rotating shafts, gears) of breakers and switches
  • Function test protection and measurement & control devices to guarantee accurate data output
  • Check cable trenches for water accumulation and debris, intact trench cover plates

12.2.4 Quarterly Maintenance (Power Cut Required)

  • Full internal cleaning of cabinet dust and moisture; wipe insulation components, busbars and transformers
  • Test circuit breaker opening/closing time and stroke to meet technical standards
  • Measure insulation resistance, transformation ratio and polarity of CT/PT to pass acceptance criteria
  • Test leakage current and insulation resistance of zinc oxide surge arresters
  • Recalibrate protection device setting values and tripping time for precise performance

12.2.5 Annual Overhaul (Full Power Cut)

  • Complete disassembly of vacuum circuit breakers; inspect contacts, arc extinguishing chambers and operating mechanisms, replace worn/damaged components
  • Replace aged sealing rings and gaskets to prevent moisture ingress
  • Conduct high-voltage withstand test (power frequency & lightning impulse) on switchgears to meet insulation standards
  • Inspect all secondary wiring, fasten terminals and replace aged secondary cables
  • Full system joint debugging to ensure coordinated operation of all equipment

13. Factory Strength & After-Sales Service

13.1 Factory Capacity & Strength

  • Production Scale: Modern manufacturing base covering 50,000㎡ land area with 30,000㎡ building area; annual output of 10,000 high-voltage switchgears, 20,000 vacuum circuit breakers and 50,000 transformers, sufficient capacity for fast delivery
  • R&D Capability: 50 professional R&D engineers including 15 senior engineers and 25 mid-level engineers; annual R&D investment accounts for 10% of sales revenue for continuous technical innovation; 30 independent intellectual property patents (5 invention patents, 25 utility model patents)
  • Production Equipment: Imported advanced German & Japanese manufacturing equipment including CNC punching machines, laser cutting machines, CNC bending machines, automatic spraying lines, dedicated vacuum circuit breaker assembly lines and high-precision testing equipment (withstand voltage testers, partial discharge detectors, mechanical characteristic testers); full-process automated production for high precision and consistent quality
  • Quality Control System: Complies with ISO9001 Quality Management System, ISO14001 Environmental Management System and ISO45001 Occupational Health & Safety Management System; strict raw material screening with top-tier suppliers including Baosteel, Tongfeng, Schneider and ABB; full inspection during production, 100% testing for key processes; finished products undergo comprehensive insulation, withstand voltage, mechanical characteristic and protection function testing before delivery; certified with CCC, CQC, KEMA and CE
  • Team Experience: 15 years of dedicated experience in high-voltage power distribution equipment R&D, production and sales; technical team average 10+ years of industry experience with mature design, production and commissioning expertise; nationwide service network familiar with power distribution demands across all industries to deliver professional customized solutions

13.2 After-Sales Service Commitment

  • Warranty Policy: 3-year full warranty for all products with free repair and component replacement during warranty period; 5-year extended warranty for core components (vacuum circuit breakers, transformers, protection devices); lifelong maintenance service, only component material fees charged post-warranty with zero labor costs
  • Rapid Response Mechanism: 24/7 nationwide service hotline; response within 2 hours upon fault notification, solution provided within 4 hours, on-site engineer arrival within 24 hours (48 hours for remote areas)
  • Installation & Commissioning Support: Free technical guidance for on-site installation and commissioning; dedicated engineers stationed for large-scale projects to provide full-process guidance through installation, commissioning and acceptance to guarantee normal system operation
  • Free Technical Training: Online and offline training covering equipment principles, operation procedures, daily maintenance and fault troubleshooting; training manuals and operation videos provided to enable independent client operation and maintenance
  • Spare Parts Supply Network: National spare parts warehouses stocking core components (vacuum circuit breakers, transformers, protection devices, sensors); emergency spare parts delivery within 3 days to minimize equipment downtime
  • Regular Customer Follow-Up: Quarterly follow-up visits during warranty period to track equipment operating status and provide maintenance recommendations; lifelong periodic follow-up for advance fault risk warning and long-term stable equipment performance
  • Customized After-Sales Packages: Exclusive service teams assigned for major projects with full lifecycle tracking; tailor-made after-sales plans to match unique project requirements

14. Conclusion

With five core advantages of high reliability, intelligence, safety, modular design and environmental friendliness, KITOZER 10kV/35kV high-voltage power distribution modules cater to power distribution demands of new energy, industrial & commercial, infrastructure and power grid sectors. All products comply with national and international standards, manufactured with advanced production equipment and strict quality control systems with multiple authoritative certifications for reliable quality.

We provide diversified customized services including personalized design, OEM/ODM manufacturing, confidential technical support and in-stock supply to meet varied client requirements. Our comprehensive after-sales system with 3-year full warranty, 24-hour emergency response and lifelong maintenance eliminates all client operational worries.

Moving forward, KITOZER will continue technological innovation to optimize product performance and upgrade intelligent functions, delivering safer, more efficient and smarter high-voltage power distribution solutions for clients. We aim to support high-quality development of the energy industry and contribute to the national carbon peaking and carbon neutrality strategic goals.

15. Search Keywords, SEO Titles & Tags

15.1 Search Keywords

10kV high-voltage distribution module, 35kV high-voltage distribution module, KITOZER high-voltage distribution equipment, 10kV switchgear, 35kV switchgear, vacuum circuit breaker, high-voltage power distribution solution, new energy step-up station, industrial & commercial power distribution, box-type substation, intelligent high-voltage distribution, high-voltage distribution equipment manufacturer, customized high-voltage distribution equipment, high-voltage distribution equipment maintenance

15.2 SEO Titles

  • Core Title: KITOZER 10kV/35kV High-Voltage Distribution Module – Intelligent High-Voltage Power Distribution Solution
  • Long-Tail Title: 10kV High-Voltage Distribution Module Manufacturer | Custom 35kV Switchgear | New Energy Step-Up Station Equipment
  • Scenario Title: 10kV Power Distribution Solution for Industrial Parks | 35kV Step-Up Station Equipment for PV Power Plants

15.3 Tags

#KITOZER #HighVoltageDistributionModule #10kVDistribution #35kVDistribution #HighVoltageSwitchgear #VacuumCircuitBreaker #NewEnergyStepUpStation #IndustrialCommercialPowerDistribution #IntelligentPowerDistribution #BoxTypeSubstation

Shopping Cart