Table of Contents
ToggleProduct Overview
The KITOZER 10kW three phase on grid solar inverter is a commercial string inverter for rooftop photovoltaic systems on small factories, office buildings, and retail centers. With three MPPT channels and a wide MPPT voltage range of 200 to 800 Vdc, it handles multiple roof orientations without derating. The inverter weighs 25 kg and mounts on a wall or floor stand, while a built in Wi-Fi and Ethernet module transmits generation data to a cloud portal. A 5 inch LCD shows yield, fault codes, and grid parameters.
Technical Specifications
AC side: three phase 400 V, 50 or 60 Hz, 10 kW continuous. DC side: three MPPT, 200 to 800 Vdc, 20 A per MPPT. Maximum DC input 15 kW. Efficiency 98 percent peak, 97.5 percent European. THDi less than 3 percent, power factor 0.99. Islanding compliant with VDE 0126, G99, EN 50549. Communication: Wi-Fi, Ethernet, optional 4G. Protection: DC switch, type 2 surge on DC and AC, arc fault detection. Enclosure IP65, weight 25 kg, dimensions 500 by 400 by 180 mm. Standards CE, IEC 62109, KITOZER 5 year warranty.
Application Scenarios
The 10 kW inverter is the standard choice for small commercial rooftop systems of 10 to 15 kW, covering factory roofs, office buildings, and shopping centers. It is also used at agricultural greenhouses and small farm installations that feed into a three phase grid. The IP65 enclosure allows outdoor mounting on a wall or ground stand, keeping the inverter out of indoor production space.
Advantages and Features
Three MPPT channels handle east, west, and south roof orientations independently, maximizing yield on complex roofs. The built in DC switch and type 2 surge protection reduce balance of system cost. Arc fault detection disconnects strings within seconds. The cloud portal shows generation data on a phone, and the inverter supports self consumption mode that adjusts export based on building load. Multiple units can be paralleled for larger systems.
Installation and Maintenance
Mount the inverter on a shaded wall or floor stand at eye level. Connect the DC strings via the integrated DC switch, and the AC side to the building distribution board via a 25 A three phase MCB and type A RCD. Pair the Ethernet with the building router during commissioning. Maintenance is limited to wiping the casing and inspecting DC connectors annually. No internal fans or consumable parts.
Price
From $680 per unit. Contact plus 86 13922289957 for commercial installer pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com