KITOZER 12 Container Data Center Quotation List
Table of Contents
Toggle2. Project Requirement Description
Project Scope: Supply and configuration of 12 containerized data center modules, each with approximate dimensions of 13.5m × 3m × 3m (IP54 protection rating, Q235B structural steel).
System Composition: Container shell and foundation, server racks and PDUs, modular UPS power supply systems (separate units for server load and precision AC load), complete power distribution, lightning protection and earthing, interior fit-out, load distribution frames, precision air conditioning (60kW × 4 units per container), environment and power monitoring (DCIM), gas fire suppression, structured network cabling, fresh air supply and forced exhaust systems.
Performance Requirements:
- UPS: Online double-conversion topology, efficiency ≥ 96%, 12V 250Ah gel batteries with 6-year warranty
- Precision AC: Constant temperature and humidity, overhead air supply, 1 unit per 2 server racks (60kW each)
- Fire Suppression: Heptafluoropropane, 8% concentration + reserve margin, total flooding type
- Monitoring: Local display + centralized platform (B/S architecture, mobile APP support)
- Earthing Resistance: ≤ 4Ω; lightning protection class B+C
- Delivery Form: Factory ex-works (EXW Guangzhou), excluding tax and freight
3. System Composition Introduction
The 12-container computing data center solution integrates the following thirteen subsystems per container:
1. Container Shell & Foundation — Welded Q235B steel structure, IP54 protection, thermal insulation, anti-corrosion coating, lighting and emergency systems
2. Server Racks & PDU Distribution — 42U standard racks, network row-head racks, dual-circuit intelligent PDUs
3. Modular UPS System (Server Load) — 150kVA modular UPS with N+1 redundancy, 12V 250Ah gel battery banks
4. Modular UPS System (Precision AC Load) — Dedicated 150kVA UPS for air conditioning loads
5. Complete Power Distribution — XL-21 distribution cabinets, ATS dual-power transfer switches, full cable suite
6. Lightning Protection & Earthing — Class B+C SPDs, dedicated earthing grid, copper busbars, ≤4Ω resistance
7. Interior Fit-out — Perforated aluminum ceiling, anti-static flooring, fire-rated steel panel walls
8. Load Distribution Frames — Custom steel frames beneath all heavy equipment for load spreading
9. Precision Air Conditioning — 60kW CRAC units, constant temp/humidity, overhead supply
10. Environment & Power Monitoring (DCIM) — Sensors, cameras, access control, centralized B/S platform
11. Gas Fire Suppression — HFC-227ea total flooding system with full detection and alarm suite
12. Network Structured Cabling — CAT6 copper + 12-core single-mode fiber, open mesh trays
13. Fresh Air & Forced Exhaust — Energy recovery ventilators, relief dampers, post-fire exhaust fans
4. Core Product Specifications & Parameters
| Category | Model | Key Parameters |
|---|---|---|
| Container Shell | KITOZER-CON-13.5 | 13.5m×3m×3m, Q235B steel, thickness ≥1.2mm, IP54, welded integral |
| Server Rack | KITOZER-RACK-42U | 600×1000×2000mm, 42U, mesh doors, load ≥1500kg, 20kW power class |
| Modular UPS | KITOZER-UPS-150K | 150kVA/135kW, three-in/three-out, online double-conversion, efficiency ≥96% |
| Gel Battery | KITOZER-BAT-250 | 12V 250Ah, gel, deep-cycle, 6-year warranty (free replacement <80% capacity) |
| Precision AC Indoor | KITOZER-CRAC-60 | 60kW cooling capacity, air-cooled, constant temp/humidity, overhead supply |
| Precision AC Outdoor | KITOZER-CRAC-CU | 60kW, air-cooled condenser, wall/rack mounted on container exterior |
| Fire Suppression Agent | KITOZER-FM-AGENT | Heptafluoropropane, purity ≥99.9%, 90L cylinders, 2.5MPa |
| DCIM Host | KITOZER-DCIM-HOST | Industrial ARM, Linux, RS485/Ethernet, local acquisition & storage |
| DCIM Platform | KITOZER-DCIM-SW | B/S architecture, centralized monitoring for 12 containers, mobile APP |
| Energy Recovery Ventilator | KITOZER-HRV-300 | 300m³/h, heat exchange ≥70%, PM2.5 filtration ≥90% |
| ATS Transfer Switch | KITOZER-ATS-400 | 400A/3P, automatic transfer ≤0.2s |
| Class B SPD | KITOZER-SPD-B | Imax=100kA, Up≤2.5kV, three-phase four-wire |
| Class C SPD | KITOZER-SPD-C | Imax=40kA, Up≤1.5kV, three-phase four-wire |
| CAT6 Cable | KITOZER-CAT6 | 4-pair UTP, CAT6, bandwidth 250MHz |
| Fiber Optic Cable | KITOZER-FIB-12 | 12-core indoor single-mode, G.652D, LSZH sheath |
5. Core Functions & Features of Products
Modular UPS (KITOZER-UPS-150K):
- Online double-conversion topology with zero transfer time
- Efficiency ≥ 96% in online mode, energy-saving ECO mode available
- N+1 parallel redundancy configuration for uninterruptible operation
- Full parameter monitoring via RS485 interface
Gel Battery (KITOZER-BAT-250):
- Valve-regulated sealed lead-acid, maintenance-free
- Deep-cycle design with 6-year warranty; free replacement if capacity drops below 80%
- Wide operating temperature range, excellent discharge performance
Precision Air Conditioning (KITOZER-CRAC-60):
- 60kW cooling capacity per unit, constant temperature (±1°C) and humidity (±5% RH)
- Overhead air supply with downward return; EC fans with variable speed
- Built-in condensate pump with ≥5m head
Fire Suppression System:
- HFC-227ea (heptafluoropropane) total flooding, 8% design concentration + 10% reserve
- Complete detection suite: photoelectric smoke + fixed-temperature heat detectors
- Emergency start/stop buttons, gas release indicator, audible & visual alarms
DCIM Monitoring Platform (KITOZER-DCIM-SW):
- B/S architecture supporting centralized monitoring of all 12 containers
- Real-time temperature, humidity, power, UPS, CRAC, leak, and access status
- Mobile APP for remote alerts and management; local 10-inch HMI touchscreen per container
Container Shell:
- IP54 protection, Q235B steel with wall thickness ≥1.2mm, fully welded
- 50mm A-grade rock wool insulation, epoxy-zinc-rich anti-corrosion coating
- Class A fire-rated steel doors with door closers and sequential closers
6. Core Advantages of The Solution
1. Turnkey Integration — All 13 subsystems supplied from a single source with unified KITOZER branding; eliminates multi-vendor coordination issues.
2. Rapid Deployment — Pre-fabricated containerized design enables fast on-site installation; each container is factory pre-assembled and tested.
3. High Reliability — N+1 redundant UPS configuration, dual power supply paths, ATS automatic transfer, and Class B+C lightning protection ensure maximum uptime.
4. Energy Efficiency — UPS efficiency ≥96%, free-cooling capable precision AC, energy recovery ventilators, and high-efficiency LED lighting reduce total operational costs.
5. Complete Monitoring — B/S-based DCIM platform with mobile APP provides 24/7 remote visibility of all power, environmental, and security parameters across all 12 containers.
6. Scalable Architecture — Standardized container modules allow incremental capacity expansion; each container is independently operable.
7. Full Compliance — ISO 9001 quality management, ISO 14001 environmental, and ISO 45001 occupational health & safety certified manufacturing.
7. Manufacturer Strength Introduction
Guangzhou Lai’an Intelligent System Development Co., Ltd. (brand: KITOZER) was founded in 2002 and is a leading provider of intelligent data center infrastructure solutions in China. The company is ISO 9001:2015 (Quality Management), ISO 14001:2015 (Environmental Management), and ISO 45001:2018 (Occupational Health & Safety) certified.
Key Strengths:
- project-confirmed Manufacturing: Own production facilities in Guangzhou, ensuring strict quality control and competitive project-confirmed pricing
- 20+ Years of Experience: Two decades of specialization in precision air conditioning, UPS power systems, DCIM monitoring, and modular data center solutions
- Comprehensive Product Line: Full in-house design and manufacturing of container shelters, racks, PDUs, distribution cabinets, monitoring systems, and integration services
- Proven Track Record: Hundreds of delivered projects across telecom, finance, government, education, and enterprise sectors
- R&D Capability: Dedicated engineering team for custom designs and project-specific configurations
8. Detailed Quotation Table
| No. | Product Name | Model & Spec | Technical Parameter | Qty | Unit | Unit Price (USD) | Total Price (USD) | Brand | Remark |
|---|---|---|---|---|---|---|---|---|---|
| Section I: Container Shell & Foundation System | |||||||||
| 1.1 | Container Data Center Shell | KITOZER-CON-13.5 | 13.5m×3m×3m, Q235B steel, wall ≥1.2mm, welded, IP54 | 12 | pcs | 43,955.31 | 527,463.67 | KITOZER | Includes frame, roof, floor, side panels; cable entry ports reserved |
| 1.2 | Double-leaf Container Door | KITOZER-DOOR-21 | 1800×2100mm, Class A steel fire door, door closer & sequential closer | 60 | sets | 2,131.07 | 127,867.10 | KITOZER | 2 front, 2 rear, 1 side per container |
| 1.3 | Container Thermal Insulation | KITOZER-INS-50 | 50mm Class A rock wool, density ≥80kg/m³, aluminum foil faced | 2,160 | m² | 30.19 | 65,213.91 | KITOZER | All six surfaces covered |
| 1.4 | Internal Anti-corrosion Treatment | KITOZER-RUST-3C | Epoxy zinc-rich primer + micaceous iron intermediate + polyurethane topcoat | 2,160 | m² | 30.19 | 65,213.91 | KITOZER | Three-coat system |
| 1.5 | General Lighting System | KITOZER-LED-40W | LED panel light, 40W, 600×600mm, 6500K, ≥300 lux | 72 | pcs | 124.32 | 8,951.59 | KITOZER | 6 pcs per container |
| 1.6 | Emergency Lighting System | KITOZER-EMG-LED | Fire-rated LED emergency light, continuous operation ≥90 min | 24 | pcs | 111.00 | 2,663.91 | KITOZER | At entrances and corridors |
| 1.7 | Safety Exit Sign | KITOZER-EXIT-LED | Fire-certified, wall-mounted | 24 | pcs | 124.32 | 2,983.57 | KITOZER | Above entrances/exits |
| 1.8 | Industrial Socket | KITOZER-SKT-10A | 10A 5-hole, with shutter protection | 96 | pcs | 55.50 | 5,327.81 | KITOZER | 8 per container, 1 per 3m |
| 1.9 | Lighting Switch | KITOZER-SW-2W | Single-pole two-way switch | 24 | pcs | 51.06 | 1,225.40 | KITOZER | 1 inside + 1 outside each door |
| Section II: Rack & PDU Power Distribution System | |||||||||
| 2.1 | Standard Server Rack | KITOZER-RACK-42U | 600×1000×2000mm, 42U, mesh door, load ≥1500kg | 105 | pcs | 1,775.94 | 186,473.29 | KITOZER | 20kW power class |
| 2.2 | Network Row-Head Rack | KITOZER-NET-42U | 600×1000×2000mm, 42U, mesh door, load ≥1000kg | 12 | pcs | 3,329.88 | 39,958.56 | KITOZER | Leftmost of each row |
| 2.3 | Rack PDU | KITOZER-PDU-32A | 16 outlets, 32A input, 8×10A + 8×16A output, display, SPD | 312 | pcs | 377.44 | 117,746.34 | KITOZER | 2 per rack, dual-circuit |
| 2.4 | Rack Fixing Bolts | KITOZER-BOLT-M12 | M12×100mm expansion bolts | 1,248 | sets | 1.33 | 1,662.33 | KITOZER | 4 sets per rack |
| 2.5 | Rack Earthing Cable | KITOZER-GND-6 | 6mm² stranded copper yellow-green wire | 312 | pcs | 16.87 | 5,263.87 | KITOZER | 2 per rack |
| Section IIIa: Modular UPS System (Server Rack Load) | |||||||||
| 3.1.1 | Modular UPS Main Unit | KITOZER-UPS-150K | 150kVA/135kW, three-in/three-out, online double-conversion, efficiency ≥96% | 12 | pcs | 75,389.08 | 904,668.94 | KITOZER | 2 units parallel, N+1 redundancy per container |
| 3.1.2 | Valve-regulated Sealed Lead-acid Battery | KITOZER-BAT-250 | 12V 250Ah, gel, deep-cycle, 6-year warranty | 576 | pcs | 888.00 | 511,427.26 | KITOZER | Free replacement if capacity <80% |
| 3.1.3 | Battery Cabinet | KITOZER-BC-C20 | C20 type, steel, holds 24× 12V batteries | 24 | pcs | 1,243.16 | 29,836.59 | KITOZER | 24 batteries per cabinet |
| 3.1.4 | Battery Connection Cable | KITOZER-BAT-CAB-70 | 70mm² flame-retardant copper, with lugs | 600 | pcs | 19.98 | 11,987.58 | KITOZER | Series connection cable |
| 3.1.5 | Battery Cabinet Earthing Cable | KITOZER-GND-16 | 16mm² stranded copper yellow-green wire | 24 | pcs | 16.87 | 404.91 | KITOZER | To earth copper busbar |
| Section IIIb: Modular UPS System (Precision AC Load) | |||||||||
| 3.2.1 | Modular UPS Main Unit | KITOZER-UPS-150K-AC | 150kVA/135kW, three-in/three-out, online double-conversion | 12 | pcs | 75,389.08 | 904,668.94 | KITOZER | For AC supply; 2 parallel per container |
| Section IV: Complete Power Distribution System | |||||||||
| 4.1 | Power Distribution Cabinet | KITOZER-PD-XL21 | XL-21 type, input 400A/3P, multiple output circuits | 12 | pcs | 2,886.93 | 34,631.02 | KITOZER | Top-three brand breakers |
| 4.2 | Server UPS Output Cabinet | KITOZER-PD-UPS-OUT | XL-21 type, input 400A/3P, 26 PDU circuits | 12 | pcs | 2,752.85 | 33,032.12 | KITOZER | With residual current protection |
| 4.3 | AC UPS Output Cabinet | KITOZER-PD-AC-OUT | XL-21 type, input 400A/3P, 4 AC circuits | 12 | pcs | 2,752.85 | 33,032.12 | KITOZER | With residual current protection |
| 4.4 | Mains ATS Dual-Power Transfer Switch | KITOZER-ATS-400 | 400A/3P, auto transfer ≤0.2s | 12 | pcs | 3,463.07 | 41,557.50 | KITOZER | Top-three brand |
| 4.5 | Rack PDU Power Cable | KITOZER-CAB-3×6 | 3×6mm² RVV, black, 5m, lugged both ends | 312 | pcs | 12.43 | 3,878.65 | KITOZER | UPS output cabinet → PDU |
| 4.6 | UPS to Mains Cabinet Cable | KITOZER-CAB-3×95+1×50 | 3×95+1×50mm² YJV, 10m | 48 | pcs | 168.72 | 8,098.27 | KITOZER | ATS cabinet → UPS main unit |
| 4.7 | Server UPS to Battery Cable | KITOZER-CAB-70-BAT | 70mm² battery cable, red/black, 8m | 48 | pcs | 33.30 | 1,598.34 | KITOZER | Positive & negative |
| 4.8 | AC UPS to Battery Cable | KITOZER-CAB-50-BAT | 50mm² battery cable, red/black, 8m | 48 | pcs | 24.42 | 1,172.12 | KITOZER | Positive & negative |
| 4.9 | UPS to Output Cabinet Cable | KITOZER-CAB-3×70+1×35 | 3×70+1×35mm² YJV, 8m | 48 | pcs | 111.00 | 5,327.81 | KITOZER | 1 per UPS |
| 4.10 | Power Cabinet to Precision AC Cable | KITOZER-CAB-3×25+1×16 | 3×25+1×16mm² YJV, 12m | 48 | pcs | 48.84 | 2,344.24 | KITOZER | To AC indoor units |
| 4.11 | PVC Conduit | KITOZER-PVC-20 | φ20mm, heavy-duty flame-retardant | 1,200 | m | 1.55 | 1,864.73 | KITOZER | Low-voltage circuits |
| 4.12 | PVC Conduit | KITOZER-PVC-32 | φ32mm, heavy-duty flame-retardant | 1,800 | m | 2.44 | 4,395.44 | KITOZER | Power cables |
| 4.13 | PVC Conduit | KITOZER-PVC-50 | φ50mm, heavy-duty flame-retardant | 1,440 | m | 3.77 | 5,434.36 | KITOZER | Large cross-section cables |
| 4.14 | Cable Clips, Conduit Clips & Fittings | KITOZER-ACC-W | Various specifications | 12 | batches | 355.19 | 4,262.25 | KITOZER | Includes ties, tape, etc. |
| Section V: Lightning Protection & Earthing System | |||||||||
| 5.1 | Class B SPD (Mains Input) | KITOZER-SPD-B | Imax=100kA, Up≤2.5kV, 3-phase 4-wire | 12 | sets | 532.78 | 6,393.37 | KITOZER | At ATS box input |
| 5.2 | Class C SPD (UPS Input) | KITOZER-SPD-C | Imax=40kA, Up≤1.5kV, 3-phase 4-wire | 48 | sets | 288.59 | 13,852.30 | KITOZER | At each UPS input |
| 5.3 | Gigabit Network Signal SPD | KITOZER-SPD-RJ45 | 1000Mbps, RJ45, response ≤1ns | 96 | pcs | 39.96 | 3,836.02 | KITOZER | Row-head rack uplink |
| 5.4 | Container to Outdoor Earth Grid Cable | KITOZER-GND-35 | 35mm² yellow-green wire, 15m | 24 | pcs | 62.16 | 1,491.80 | KITOZER | Busbar → outdoor grid |
| 5.5 | Outdoor Lightning Protection Earth Grid | KITOZER-GND-NET | 50×5mm hot-dip galvanized flat steel, bury depth ≥0.8m | 360 | m | 11.10 | 3,995.86 | KITOZER | Closed ring, ≤4Ω |
| 5.6 | Earth Electrode | KITOZER-GND-ROD | 50×50×2500mm hot-dip galvanized angle steel | 96 | pcs | 37.74 | 3,623.78 | KITOZER | 1 per 5m |
| 5.7 | Indoor Earthing Copper Busbar | KITOZER-GND-BUS | 30×3mm tinned copper busbar | 180 | m | 37.74 | 6,792.96 | KITOZER | Top & bottom of rack rows |
| 5.8 | Indoor Earthing Copper Foil | KITOZER-GND-FOIL | 0.3mm×100mm copper foil | 1,080 | m² | 24.42 | 26,373.83 | KITOZER | Grid 600×600mm |
| 5.9 | Earthing Hub Busbar | KITOZER-GND-HUB | 100×10mm copper busbar, L=1000mm | 12 | pcs | 266.39 | 3,196.69 | KITOZER | At container entrance |
| 5.10 | Lightning & Earthing Box | KITOZER-GND-BOX | Integrated SPD earthing box, terminal blocks, SPD module | 12 | sets | 421.79 | 5,061.12 | KITOZER | At outdoor cable entry |
| 5.11 | Earthing Connection Cable | KITOZER-GND-6 | 6mm² yellow-green wire | 600 | pcs | 2.66 | 1,598.34 | KITOZER | Equipment earthing |
| Section VI: Interior Fit-out System | |||||||||
| 6.1 | Micro-perforated Aluminum Ceiling | KITOZER-CEIL-AL | 600×600×0.8mm, micro-perforated, sound absorption ≥0.6 | 486 | m² | 74.59 | 36,251.94 | KITOZER | Includes suspension system |
| 6.2 | Cleanroom Steel Panel Wall | KITOZER-WALL-50 | 50mm thick, double-sided color steel, rock wool core, Class A fire rating | 1,068 | m² | 124.32 | 132,748.56 | KITOZER | Full wall coverage |
| 6.3 | All-steel Anti-static Floor | KITOZER-FLR-600 | 600×600×35mm, cement-filled, load ≥1000kg/m² | 486 | m² | 124.32 | 60,416.75 | KITOZER | Includes pedestals & stringers |
| 6.4 | Floor Dust & Moisture Treatment | KITOZER-FLR-EP | Epoxy primer + intermediate + topcoat, 3 coats | 486 | m² | 13.32 | 6,473.59 | KITOZER | Under false floor |
| 6.5 | Wall Fire-retardant Treatment | KITOZER-WALL-FP | Fire-retardant coating, fire resistance ≥1h | 1,068 | m² | 7.99 | 8,535.37 | KITOZER | On steel panel substrate |
| 6.6 | Wall Waterproofing Treatment | KITOZER-WALL-WP | Polyurethane waterproofing, thickness ≥1.5mm | 120 | m² | 11.10 | 1,331.96 | KITOZER | AC area |
| 6.7 | Door & Window Fire Sealing | KITOZER-FP-SEAL | Fire-stop putty + board + sealant | 60 | m² | 37.74 | 2,264.31 | KITOZER | Gaps & openings |
| 6.8 | AC Water Retention Dike | KITOZER-WB-C20 | C20 concrete, 100×100mm, tiled finish | 48 | pcs | 79.92 | 3,836.02 | KITOZER | Below each AC unit |
| 6.9 | Rubber-plastic Insulation | KITOZER-INS-20 | 20mm thick, B1 fire-rated, λ≤0.034 | 240 | m² | 12.43 | 2,983.57 | KITOZER | Ducts & pipes |
| Section VII: Load Distribution Frame System | |||||||||
| 7.1 | Server Rack Load Frame | KITOZER-SLF-600 | 600×1000mm, steel, load ≥2000kg | 144 | pcs | 168.72 | 24,294.51 | KITOZER | 1 per rack |
| 7.2 | Row-Head Rack Load Frame | KITOZER-SLF-600N | 600×1000mm, load ≥1500kg | 12 | pcs | 155.40 | 1,864.73 | KITOZER | Under row-head racks |
| 7.3 | Battery Cabinet Load Frame | KITOZER-SLF-BAT | Custom, load ≥3000kg | 48 | pcs | 244.19 | 11,721.19 | KITOZER | 1 per battery cabinet |
| 7.4 | Precision AC Load Frame | KITOZER-SLF-AC | Custom, load ≥1500kg | 48 | pcs | 168.72 | 8,098.27 | KITOZER | 1 per AC unit |
| 7.5 | Distribution Cabinet Load Frame | KITOZER-SLF-PD | Custom, load ≥1000kg | 48 | pcs | 142.09 | 6,819.18 | KITOZER | Power/ATS/output cabinets |
| 7.6 | UPS Load Frame | KITOZER-SLF-UPS | Custom, load ≥1500kg | 48 | pcs | 168.72 | 8,098.27 | KITOZER | 1 per UPS main unit |
| 7.7 | Load Frame Fixing Bolts | KITOZER-BOLT-M16 | M16×120mm expansion bolts | 2,592 | sets | 1.78 | 4,602.34 | KITOZER | 4 sets per frame |
| Section VIII: Precision Air Conditioning System | |||||||||
| 8.1 | Precision AC Indoor Unit | KITOZER-CRAC-60 | 60kW, air-cooled, constant temp/humidity, overhead supply | 48 | pcs | 23,087.17 | 1,108,183.52 | KITOZER | 1 per 2 server racks |
| 8.2 | Precision AC Outdoor Unit | KITOZER-CRAC-CU | 60kW, air-cooled, matches indoor unit | 48 | pcs | 5,327.81 | 255,734.20 | KITOZER | Wall/rack mounted outside |
| 8.3 | AC Connection Copper Pipe | KITOZER-CU-TUBE | φ19+φ12mm copper tube, wall ≥0.8mm | 480 | m | 122.10 | 58,606.19 | KITOZER | With insulation |
| 8.4 | AC Refrigerant Branch | KITOZER-BRANCH | Copper, matches pipe | 96 | pcs | 37.74 | 3,623.78 | KITOZER | 2 per unit |
| 8.5 | AC Refrigerant | KITOZER-R410A | R410A eco-friendly refrigerant | 480 | kg | 19.98 | 9,590.06 | KITOZER | 10kg per unit |
| 8.6 | AC Condensate Drain Pipe | KITOZER-DRAIN-32 | φ32mm PVC-U, insulated | 480 | m | 5.33 | 2,557.34 | KITOZER | Slope ≥1% |
| 8.7 | AC Condensate Lift Pump | KITOZER-COND-PUMP | Head ≥5m, flow ≥2m³/h | 48 | pcs | 244.19 | 11,721.19 | KITOZER | 1 per AC unit |
| 8.8 | AC Power Cable | KITOZER-CAB-3×25+1×16 | 3×25+1×16mm² YJV, 10m | 480 | m | 48.84 | 23,442.36 | KITOZER | 10m per unit |
| 8.9 | AC Control Cable | KITOZER-CAB-CTL | RVVP 4×1.5mm² shielded, 10m | 480 | m | 3.55 | 1,704.92 | KITOZER | Indoor-outdoor connection |
| 8.10 | AC Installation Accessories | KITOZER-ACC-AC | Brackets, bolts, sealant, etc. | 48 | sets | 142.09 | 6,819.18 | KITOZER | 1 set per unit |
| Section IX: Environment & Power Monitoring (DCIM) System | |||||||||
| 9.1 | Temperature & Humidity Sensor | KITOZER-TH-RS | Accuracy ±0.5°C/±3%RH, RS485 | 48 | pcs | 124.32 | 5,967.14 | KITOZER | 1 per 3m |
| 9.2 | Network Camera | KITOZER-CAM-2MP | 2MP, POE, IR night vision ≥30m | 24 | pcs | 333.00 | 7,991.71 | KITOZER | Entrances + equipment area |
| 9.3 | Leak Detection Sensor | KITOZER-WLD | Water-immersion rope type, location ±1m, RS485 | 48 | pcs | 199.80 | 9,590.06 | KITOZER | Below AC units |
| 9.4 | Multi-function Power Meter | KITOZER-PM-RS | Monitors V/A/W etc., RS485 | 48 | pcs | 377.44 | 18,114.25 | KITOZER | Power/ATS/output cabinets |
| 9.5 | UPS Monitoring Module | KITOZER-UPS-MON | RS485, monitors all UPS parameters | 48 | pcs | 288.59 | 13,852.30 | KITOZER | 1 per UPS |
| 9.6 | AC Monitoring Module | KITOZER-AC-MON | RS485, monitors AC status & faults | 48 | pcs | 244.19 | 11,721.19 | KITOZER | 1 per AC unit |
| 9.7 | Access Control All-in-one | KITOZER-ACC-ALL | Fingerprint + PIN + card, 1000 fingerprints | 12 | pcs | 1,243.16 | 14,918.90 | KITOZER | Outside entrance door |
| 9.8 | Magnetic Lock | KITOZER-MAG-280 | 280kg holding force, single door, with door sensor | 12 | pcs | 155.40 | 1,864.73 | KITOZER | Inside entrance door |
| 9.9 | Exit Button | KITOZER-EXIT-BTN | Plastic, normally-open contact | 12 | pcs | 11.10 | 133.20 | KITOZER | Inside entrance door |
| 9.10 | Access Control Power Supply | KITOZER-PWR-12V | 12V/5A, with backup battery | 12 | pcs | 124.32 | 1,491.80 | KITOZER | For access control |
| 9.11 | Passive Infrared Detector | KITOZER-PIR | Detection ≥10m, angle 110°, pet immune | 24 | pcs | 79.92 | 1,918.04 | KITOZER | Diagonal installation |
| 9.12 | DCIM Monitoring Host | KITOZER-DCIM-HOST | Industrial ARM, Linux, RS485/Ethernet | 12 | pcs | 2,441.91 | 29,303.21 | KITOZER | Local acquisition & storage |
| 9.13 | Industrial Touch Screen | KITOZER-HMI-10 | 10″ color, resistive, 800×600 | 12 | pcs | 976.76 | 11,721.19 | KITOZER | Local HMI |
| 9.14 | DCIM Centralized Platform Software | KITOZER-DCIM-SW | B/S architecture, 12-container central monitoring, mobile APP | 1 | set | 16,871.32 | 16,871.32 | KITOZER | Cloud/local deployment |
| 9.15 | DCIM System Cables | KITOZER-CAB-DCIM | RVV 2×1.5 + RVSP 2×1.5 + network cable | 2,400 | m | 2.66 | 6,393.37 | KITOZER | As required |
| Section X: Gas Fire Suppression System | |||||||||
| 10.1 | Photoelectric Smoke Detector | KITOZER-SD | Response threshold 0.15~0.3dB/m | 72 | pcs | 82.14 | 5,913.99 | KITOZER | 1 per 20m² |
| 10.2 | Fixed-temperature Heat Detector | KITOZER-TD | Alarm temperature 68°C | 72 | pcs | 82.14 | 5,913.99 | KITOZER | Staggered arrangement |
| 10.3 | Manual/Auto Transfer Button | KITOZER-MA-BTN | With key lock | 24 | pcs | 97.68 | 2,344.24 | KITOZER | 1 inside + 1 outside |
| 10.4 | Emergency Start/Stop Button | KITOZER-ES-BTN | With protective cover | 24 | pcs | 111.00 | 2,663.91 | KITOZER | 1 inside + 1 outside |
| 10.5 | Gas Discharge Indicator Light | KITOZER-REL-LED | Red flashing, “Gas Discharge – Do Not Enter” | 24 | pcs | 79.92 | 1,918.04 | KITOZER | Inside & outside entrance |
| 10.6 | Fire Audible & Visual Alarm | KITOZER-SA | Sound ≥100dB, red flashing | 24 | pcs | 93.24 | 2,237.71 | KITOZER | 1 inside + 1 outside |
| 10.7 | Fire Alarm Bell | KITOZER-BELL | Sound ≥90dB | 12 | pcs | 82.14 | 985.65 | KITOZER | Outside container |
| 10.8 | Heptafluoropropane Cylinder | KITOZER-FM-90L | 90L steel seamless, working pressure 2.5MPa | 24 | pcs | 2,211.65 | 53,065.91 | KITOZER | Left side of container |
| 10.9 | Heptafluoropropane Agent | KITOZER-FM-AGENT | Purity ≥99.9% | 128.4 | kg | 37.74 | 4,845.68 | KITOZER | 8% concentration + 10% reserve |
| 10.10 | Cylinder Head Valve | KITOZER-VALVE | Electromagnetic actuation, with pressure gauge | 24 | pcs | 199.80 | 4,795.32 | KITOZER | Top of cylinder |
| 10.11 | Selection Valve | KITOZER-SEL-VALVE | DN50, pneumatic actuation | 24 | pcs | 168.72 | 4,049.14 | KITOZER | Controls discharge |
| 10.12 | Gas Delivery Piping | KITOZER-PIPE-DN50 | DN50 seamless steel, galvanized | 240 | m | 43.51 | 10,442.50 | KITOZER | Ceiling installation |
| 10.13 | Nozzle | KITOZER-NOZZLE | Total-flooding, atomization 120° | 96 | pcs | 73.26 | 7,032.77 | KITOZER | 1 per 15m² |
| 10.14 | Fire Alarm Controller | KITOZER-FACP | Wall-mounted, 2 loops, 32 points | 12 | pcs | 1,687.13 | 20,245.97 | KITOZER | Local control |
| 10.15 | Fire System Cables | KITOZER-CAB-FIRE | RVV 2×1.5 + RVSP 2×1.5 | 2,400 | m | 2.22 | 5,327.81 | KITOZER | As required |
| Section XI: Network Structured Cabling System | |||||||||
| 11.1 | Open Mesh Cable Tray | KITOZER-CBT-200 | 200×100mm, galvanized steel, mesh 50×100mm | 240 | m | 42.18 | 10,122.84 | KITOZER | Overhead routing |
| 11.2 | Cable Tray Bracket | KITOZER-CBT-BR | For 200mm width, galvanized | 480 | pcs | 5.33 | 2,557.34 | KITOZER | 1 per 0.5m |
| 11.3 | CAT6 Unshielded Network Cable | KITOZER-CAT6 | 4-pair UTP, CAT6, 250MHz bandwidth | 1,872 | pcs | 12.43 | 23,272.28 | KITOZER | 12 per rack × 10m |
| 11.4 | 24-Port CAT6 UTP Patch Panel | KITOZER-PNL-24 | 1U, CAT6, with cable manager ring | 96 | pcs | 124.32 | 11,934.29 | KITOZER | 1 per 24 cables |
| 11.5 | 1U Metal Cable Manager | KITOZER-CM-1U | Steel, 12 cable rings | 96 | pcs | 19.98 | 1,918.04 | KITOZER | Matching patch panels |
| 11.6 | CAT6 Network Module | KITOZER-MOD-CAT6 | CAT6, unshielded, RJ45 | 3,744 | pcs | 2.66 | 9,973.36 | KITOZER | Both ends of each cable |
| 11.7 | 12-Core Indoor Single-mode Fiber | KITOZER-FIB-12 | G.652D, LSZH sheath | 156 | pcs | 42.18 | 6,579.84 | KITOZER | 1 per rack × 10m |
| 11.8 | 24-Port LC Single-mode Fiber Patch Panel | KITOZER-FIB-PNL | 1U, with couplers & pigtails | 96 | pcs | 142.09 | 13,639.48 | KITOZER | 1 per 24 cores |
| 11.9 | LC Single-mode Fiber Coupler | KITOZER-AD-LC | Ceramic ferrule, low insertion loss | 2,304 | pcs | 3.55 | 8,183.61 | KITOZER | 24 per patch panel |
| 11.10 | LC-LC Single-mode Fiber Pigtail | KITOZER-PIG-LC | 1m, LSZH | 2,304 | pcs | 5.33 | 12,275.35 | KITOZER | 24 per patch panel |
| 11.11 | Fiber Fusion Splicing | KITOZER-SPLICE | Single-mode, loss ≤0.1dB | 22,464 | cores | 0.89 | 19,943.79 | On-site | Both ends of each 12-core cable |
| 11.12 | Cable Labels | KITOZER-LABEL | Waterproof, oil-resistant, abrasion-proof | 12 | batches | 88.80 | 1,065.77 | KITOZER | Label all cables |
| Section XII: Fresh Air & Forced Exhaust System | |||||||||
| 12.1 | Total Heat Exchange Fresh Air Unit | KITOZER-HRV-300 | 300m³/h, heat exchange ≥70%, PM2.5 filtration ≥90% | 12 | pcs | 3,019.11 | 36,229.10 | KITOZER | Fresh air supply |
| 12.2 | Square Diffuser Supply Air Outlet | KITOZER-DIFF-300 | 300×300mm, aluminum, adjustable airflow | 24 | pcs | 82.14 | 1,971.61 | KITOZER | Ceiling-mounted |
| 12.3 | Square Louver Exhaust Outlet | KITOZER-LOU-300 | 300×300mm, aluminum, adjustable airflow | 24 | pcs | 79.92 | 1,918.04 | KITOZER | Ceiling-mounted |
| 12.4 | Outdoor Weatherproof Louver | KITOZER-LOU-EXT | 300×300mm, aluminum, with insect screen | 24 | pcs | 93.24 | 2,237.71 | KITOZER | External wall |
| 12.5 | Galvanized Steel Duct | KITOZER-DUCT-200 | 0.5mm thick, 200×200mm rectangular | 180 | m | 108.77 | 19,579.92 | KITOZER | Connects HRV |
| 12.6 | Flexible Duct Connection | KITOZER-FLEX | Canvas, fire-retardant | 48 | pcs | 15.54 | 745.89 | KITOZER | Vibration isolation |
| 12.7 | Fresh Air Control Box | KITOZER-HRV-CTL | Manual/auto, programmable time & speed | 12 | pcs | 288.59 | 3,463.07 | KITOZER | Controls HRV |
| 12.8 | Gas Fire Relief Damper | KITOZER-REL-VALVE | Opens at 70Pa, aluminum | 12 | pcs | 199.80 | 2,397.66 | KITOZER | External wall |
| 12.9 | Forced Exhaust Fan | KITOZER-EXF-500 | 500m³/h, axial, flame-retardant | 12 | pcs | 532.78 | 6,393.37 | KITOZER | Post-fire smoke exhaust |
| 12.10 | Exhaust Outlet | KITOZER-EXF-GRILL | 300×300mm, aluminum, normally-closed electric | 12 | pcs | 124.32 | 1,491.80 | KITOZER | Ceiling-mounted |
Total Quotation Price: USD 6,209,706.67
*Note: Unit prices reflect the standardized KITOZER brand configuration with an integrated pricing structure. The grand total is USD 6,209,706.67 (equivalent to CNY 41,958,170 at the fixed conversion rate of 1 USD = 6.7570 CNY).*
9. Quotation Terms & Conditions
1. Price Basis: All prices are quoted on EXW (Ex-Works) Guangzhou basis, excluding value-added tax and freight. USD prices are converted from CNY at the fixed rate of 1 USD = 6.7570 CNY.
2. Quotation Validity: This quotation remains valid for 30 days from the date of issue. Final pricing is subject to written confirmation by both parties.
3. Payment Terms: 30% advance deposit by T/T upon contract signing; 70% balance payment before shipment. Alternative payment arrangements may be negotiated on a case-by-case basis.
4. Tax Invoicing: For special VAT invoice (deductible), an additional 10% surcharge applies. For ordinary VAT invoice, an additional 3% surcharge applies.
5. Freight: Shipping/freight costs are to be borne by the buyer (collect) or arranged via logistics at the buyer’s expense.
6. Delivery Lead Time: Approximately 45-60 working days after receipt of the advance payment and final technical confirmation, subject to order quantity and configuration.
7. Brand Policy: All equipment is supplied under the unified KITOZER (Guangzhou Lai’an) brand. No substitution of brands is permitted unless specifically agreed in writing.
8. Technical Confirmation: The buyer shall review and confirm all technical specifications, drawings, and interface details prior to manufacturing.
9. Inspection: Final inspection and factory acceptance testing (FAT) shall be conducted at the manufacturer’s facility prior to shipment. Buyer representatives are welcome to attend.
10. Contract Finalization: This quotation serves as a basis for negotiation. The formal contract shall prevail upon execution by both parties.
10. After-sales Service Description
Warranty Coverage:
- Standard Equipment Warranty: 12 months from the date of commissioning or 18 months from the date of shipment, whichever occurs first. Extended warranty up to 24 months is available upon request.
- Battery Warranty: The 12V 250Ah gel batteries carry a 6-year warranty. If battery capacity drops below 80% of rated capacity during the warranty period, the batteries will be replaced free of charge.
- UPS System: Full parts and labor warranty on the modular UPS main units for the warranty period.
Service Commitments:
1. Remote Technical Support: Free telephone, email, and remote diagnostic support during business hours (9:00–18:00, China Standard Time, Monday–Saturday).
2. On-site Service: For issues that cannot be resolved remotely, our engineers will provide on-site service. Response time: within 48 hours for domestic customers; for overseas customers, online remote guidance is provided immediately with on-site dispatch arranged through authorized local partners.
3. Spare Parts: Critical spare parts are maintained in stock at the factory to minimize downtime.
4. Preventive Maintenance: Optional annual preventive maintenance contracts are available, including system inspection, cleaning, battery testing, and performance verification.
5. Training: Free operator training (remote or on-site, subject to arrangement) covering system operation, routine maintenance, and emergency procedures for the DCIM platform, UPS system, precision AC, and fire suppression systems.
6. Documentation: Full technical documentation package delivered with the system, including drawings, manuals, wiring diagrams, and commissioning reports.
11. Contact & Order Information
Company: Guangzhou Lai’an Intelligent System Development Co., Ltd.
Brand: KITOZER (KITOZER)
Legal Entity (Manufacturing Affiliate): Guangdong Lai’an Smart Data Center Equipment Co., Ltd.
Contact Person: Mr. Zhou
Mobile / WeChat: +86 13538869979
Order Channel: Official website: www.gdlain.com (online ordering and inquiry supported)
Factory Address: Chaotian Area, Zhongrun Industrial Park, No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou, Guangdong Province, China
How to Place an Order:
1. Submit an inquiry via www.gdlain.com or contact Mr. Zhou directly at +86 13538869979
2. Provide project requirements, site conditions, and any custom configuration needs
3. Receive a formal quotation and technical proposal for review
4. Sign the sales contract and technical agreement
5. Make the 30% advance payment to commence production
6. Receive factory acceptance test (FAT) report and shipping arrangement
7. Balance payment and shipment, followed by on-site commissioning support
Business Hours: Monday – Saturday, 9:00–18:00 (China Standard Time, UTC+8)
12. SEO Keywords & Tags
Primary Keywords: container data center, modular data center, KITOZER, 12-container data center, computing data center, containerized data center solution, prefabricated data center
Product Keywords: modular UPS 150kVA, gel battery 12V 250Ah, precision air conditioning 60kW, HFC-227ea fire suppression, DCIM monitoring platform, container shell IP54, server rack 42U, PDU 32A, ATS transfer switch, CAT6 cabling, single-mode fiber, energy recovery ventilator, lightning protection Class B+C, anti-static flooring, load distribution frame
Solution Keywords: high-density computing infrastructure, edge data center, containerized IT infrastructure, turnkey data center solution, N+1 redundant UPS, constant temperature humidity control, B/S architecture monitoring, mobile APP monitoring, green energy-efficient data center
Target Application Tags: cloud computing, edge computing, AI computing, HPC (high-performance computing), telecom, smart city, industrial IoT, financial services, government data centers, enterprise IT infrastructure