Table of Contents
ToggleProduct Overview
The KITOZER 12-port Optical Distribution Frame (ODF) is a compact rack-mount enclosure designed to terminate, organize, and manage up to 12 fiber optic cables in enterprise network rooms, telecom central offices, and campus fiber backbones. Built from cold-rolled steel with a durable powder-coated finish, the 1U chassis houses splice trays, adapter panels, and pigtail management in a single integrated unit. The front-loading SC UPC adapter panel allows direct patching to active equipment, while the rear cable entry supports both round cable and fan-out breakout cords. Each port is clearly numbered for quick identification during moves, adds, and changes.
The enclosure is engineered to protect fusion splices and adapter end faces from dust, mechanical strain, and accidental contact. A split top cover lifts off without tools, giving installers full access to the internal splice area during commissioning. The slide-out tray extends forward on steel runners, so technicians can work on pigtails and adapters without removing patch cords already in service. This design minimizes service disruption when additional fibers are added to an existing link.
Technical Specifications
Housing: 1U 19-inch rack mount, cold-rolled steel 1.2mm, black powder coat. Adapter interface: 12 x SC UPC simplex adapters, ceramic zirconia sleeve. Splice capacity: 12 cores via integrated 1U splice tray with 12 fusion splice protectors. Fiber type: singlemode OS2 standard, multimode OM3/OM4 available on request. Insertion loss per adapter: less than 0.25dB UPC, return loss greater than 50dB. Cable entry: rear gland plate supporting up to 2 round cables of 10mm to 16mm diameter. Operating temperature: -10C to +60C. Dimensions: 482mm x 250mm x 44mm. Mounting: EIA 19-inch rack with front and rear brackets. Includes: 12 SC pigtails 1.5m, splice tray, cable ties, grounding wire. Brand: KITOZER. Warranty: 3 years.
The unit is supplied with factory-terminated pigtails pre-cut to 1.5 meters, each with an SC UPC connector on one end and a bare fiber on the other for fusion splicing. The splice tray accepts standard 60mm heat-shrink splice protectors and holds them in individual grooves so they cannot shift during tray closure. A built-in grounding lug bonds the chassis to the rack earth, providing ESD protection for sensitive fiber end faces. The gland plate uses compression nuts that accept cable diameters from 10mm to 16mm without additional adapters.
Applications
This 12-port ODF is ideal for small server rooms, remote branch offices, and enterprise wiring closets where fiber backbones terminate directly into aggregation switches. It is also widely used in FTTH central office splitters, CCTV surveillance fiber rings, and industrial control room fiber termination. The compact 1U height makes it suitable for edge computing cabinets, outdoor telecom cabinets, and test equipment racks where space is constrained.
Typical deployment patterns include a 12-fiber backbone from a main distribution frame (MDF) landing in a wiring closet ODF, with patch cords running from the ODF to a local Gigabit or 10G switch. In campus environments, the ODF may serve as the intermediate cross-connect (ICC) between building riser fibers and horizontal fiber outlets. The unit also works well as a demarcation point between carrier-provided fiber and customer premises equipment.
Key Advantages
Slide-out tray design allows technicians to access splice trays without removing patch cords from the front panel, reducing service disruption. All adapters are pre-loaded and factory tested, ensuring consistent insertion loss across every port. The split rear gland plate accommodates multiple cable diameters without requiring custom fittings. Cable radius is protected by integrated radius guides that maintain the 30mm bend radius required for bend-insensitive fiber. Numbered port labels and color-coded pigtails (blue for singlemode) simplify troubleshooting. The unit is fully grounded to the rack for ESD safety.
Compared with bulkhead adapter panels that require separate splice trays, this integrated ODF saves rack space and reduces on-site assembly time. The modular adapter plate can be converted from SC to LC in the field by swapping the adapter frame, protecting the enclosure investment as network speeds increase. Every unit is 100 percent factory tested for insertion loss and visual continuity before shipment, reducing commissioning callbacks.
Installation and Maintenance
Mount the ODF in a 19-inch rack using the included M6 cage nuts and screws. Route incoming fiber cable through the rear gland plate, strip the outer jacket, and fan the individual fibers into the splice tray. Fusion splice each incoming fiber to a 1.5m SC pigtail, then place the splice protector into the tray groove. Close the tray, seat the SC adapters into the front panel, and connect pigtail ends to the adapters. Label both ends of each fiber with a unique identifier matching the as-built documentation.
During maintenance, always clean adapter end faces with lint-free wipes and isopropyl alcohol before mating. Keep dust caps installed on unused ports. Inspect cable gland tightness annually and re-torque if needed. Perform a yearly visual inspection of splice trays to confirm that splice protectors remain seated and that no fiber has overheated or stretched. If a port shows excessive insertion loss, clean the ferrule first, and only re-splice after cleaning fails to restore the loss budget.
Packaging and Compliance
The ODF is packed in a corrugated carton with foam corner protectors and a plastic bag to prevent dust. Each carton includes a test report, installation manual, and spare dust caps. The product meets RoHS and CE requirements. Custom branding, connector types, and pigtail lengths are available on request for volume orders.
Price
From $85/pc. Contact +86 13922289957 for factory quotation and lead time.