ToggleProduct Overview
The KITOZER 120 kW dual-compressor N plus 1 variable-frequency precision air conditioner is built for high-density enterprise data centers that require built-in redundancy without purchasing a fully separate standby unit. Two independent refrigeration circuits share a common air handler, each driven by an inverter scroll compressor. If one circuit faults, the second continues cooling at partial capacity while alarm notifications are sent. The controller automatically rotates lead-lag operation so both compressors accumulate equal run hours, extending service life and avoiding the uneven wear that shortens the life of fixed-lead systems. The cabinet supports downflow discharge into raised floors or upflow into ceiling plenums. Condensate management, electrical main breaker, and controller are all factory-wired and tested before shipment.
Technical Specifications
Total nominal cooling is 120 kW sensible at 23 degrees Celsius and 50 percent relative humidity, split across two 60 kW circuits. Each circuit uses an inverter scroll compressor with R410A refrigerant and electronic expansion valve. Supply airflow is 28,000 cubic meters per hour against 250 Pa static. Power supply is three phase 400 V 50 Hz, with total electrical input 42 kW. The steam humidifier outputs 12 kg per hour. Dimensions are 2800 mm wide by 1200 mm deep by 2000 mm high. The unit weighs approximately 1150 kg. Noise is 74 dBA at 3 meters. Communication includes Modbus TCP, BACnet IP, SNMP, and optional 4G modem. The outdoor condensers are V-type with EC axial fans and weatherproof junction boxes.
Application Scenarios
This model is deployed in mission-critical halls where uptime tiers require redundancy but floor space is at a premium. Typical users include cloud service providers, banking core systems, telecom operator computer rooms, government data centers, and pharmaceutical manufacturing facilities with controlled environment needs. It is especially suitable for retrofits where adding a second standalone unit would violate aisle width or fire separation requirements. The dual-circuit design also suits offshore platform control rooms, shipping vessel server spaces, and remote unmanned telecom sites where on-site spares are scarce.
Advantages and Features
Dual independent circuits deliver true N plus 1 redundancy within a single footprint. Inverter compressors modulate from 25 to 100 percent capacity, matching IT load smoothly and avoiding frequent starts that wear mechanical components. The controller runs duty rotation, alarm logging, and energy metering, and can be linked to adjacent units for group sequencing. Hot-aisle containment integration is supported by adjustable discharge velocity and static pressure control. The cabinet uses corrosion-coated coil fins for coastal installations. Front-serviceable filters and components minimize downtime during maintenance. A built-in web server exposes live trends, alarm history, and energy-use dashboards to any authorized browser on the local network. The controller also supports scheduled start-stop based on IT load patterns, avoiding unnecessary cooling during weekends or holiday periods.
Installation and Maintenance Recommendations
Because of the cabinet weight, floor loading should be verified against structural drawings. Refrigerant piping to the outdoor condenser should be sized by a certified refrigeration engineer, with oil return loops and insulation. Maintenance includes quarterly filter inspection, semi-annual compressor vibration and current check, annual refrigerant leak test and valve calibration, and 3-year oil analysis for the inverter scroll compressors. Keep spare contactors, sensors, and an EEV coil on site. Verify crankcase heater operation before winter startup in cold-climate installations. Commissioning should include a leak test on both refrigerant circuits, a pressure test on the water and gas piping, and a forced-fault test that proves the standby circuit takes over within seconds. Operators should be trained on duty-rotation settings, alarm escalation, and the procedure for isolating a faulty circuit without shutting down the room.
Energy and Environmental Performance
Inverter compressors modulate capacity smoothly, avoiding the energy spikes associated with frequent start-stop cycling. The part-load EER of the unit exceeds 3.5 at half load, contributing to a competitive data center PUE. R410A refrigerant has no ozone depletion potential, and the cabinet uses CFC-free foam insulation. The EC fans on the outdoor condenser also slow down in cool weather, reducing both energy consumption and noise. The design is fully compliant with current eco-design directives for commercial refrigeration.
Configuration Options and Warranty
The unit can be ordered with upflow or downflow discharge, left- or right-hand electrical entry, and a choice of R410A or R32 refrigerant where local regulations favor lower GWP fluids. Optional extras include a humidifier bypass, a remote human-machine interface panel, a SNMP module, and a corrosion-resistant coil coating for coastal sites. The standard warranty covers compressors for 3 years and the cabinet for 1 year, with extended coverage up to 5 years available. Factory commissioning and operator training are recommended for first-time installations.