The KITOZER 120 kW open frame diesel generator delivers 150 kVA standby power for mid-sized factories, warehouses, hospitals, and commercial complexes where a dedicated generator room already exists. Coupling a six-cylinder turbocharged diesel engine to a heavy-duty brushless alternator, the set is engineered for continuous daily duty cycles rather than occasional standby, and its robust frame, large radiator, and high-capacity fuel system support multi-hour runtimes under full load. The open skid simplifies integration with customer-built acoustic enclosures, elevated fuel day tanks, and parallel switchgear, making it a flexible building block for engineering contractors.
Table of Contents
ToggleTechnical Specifications
Standby 132 kW (165 kVA), prime 120 kW (150 kVA), 400V three-phase 50Hz, 0.8 power factor. Engine: six-cylinder, water-cooled, turbocharged and aftercooled, direct injection, 1500 rpm. Alternator: brushless, self-excited, AVR, class H, IP23, winding temperature sensors. Controller: deep-sea DSE7320 or ComAp InteliLite, LCD, Modbus RS485, USB. Circuit breaker: 250A three-phase MCCB. Sub-base tank 400 L, optional external day tank 1000 L. Battery 24V 120Ah dual. Dimensions roughly 2800 x 1000 x 1500 mm, dry weight 2400 to 2800 kg. Fuel consumption at 75 percent load approximately 28 L per hour.
Key Advantages
The 120 kW rating comfortably starts motors up to 45 kW direct-on-line, thanks to the alternator surge capability of 300 percent for 10 seconds. The electronic governor keeps frequency stable through large load steps, protecting production equipment. The control panel offers remote start, remote stop, scheduled exercise, and email or SMS alarm notifications when paired with an optional GSM module. Because the set is open frame, technicians can inspect the belt, coolant hoses, and electrical connections during weekly rounds without removing sound panels. KITOZER supplies the unit with factory load-bank tested performance certificate and thermal scan report.
Applications
This size is widely used as the primary standby source for plastic injection molding workshops, metal stamping plants, textile mills, food processing lines, and cold storage warehouses. Hospitals and clinics rely on it to keep operating theatres, lifts, and refrigeration running during utility outages. Commercial office towers use the 120 kW set for life safety loads, emergency lighting, and selected HVAC fans. Data center edge rooms, telecom exchanges, and water pumping stations also choose this rating because it fits a standard generator room without requiring heavy crane access. Agricultural users power grain drying, milking parlors, and irrigation booster pumps.
Installation and Maintenance
The concrete foundation must be reinforced and at least 250 mm thick, sized 300 mm beyond the skid on all sides. Install heavy-duty spring or rubber anti-vibration mounts to isolate engine noise from the building structure. Ventilation airflow should be calculated at 1000 m3 per hour per 10 kW of engine heat rejection, with separate inlet and outlet ducts to avoid recirculation. Exhaust pipe diameter is typically 5 inches, wrapped in 50 mm glass wool and led outside with a rain cap and flexible bellows. Fuel supply lines use 3/4 inch steel tubing with a manual cock at the day tank and a water trap at the generator.
Maintenance schedule: engine oil and filter every 250 hours, fuel filter every 500 hours, air filter service every 500 hours or when restriction indicator trips, coolant replacement every 2 years, valve lash every 2000 hours. Perform a load bank test annually at 100 percent, 75 percent, and 50 percent load for one hour each to confirm engine health and alternator temperature rise. Keep battery terminals greased and float charger active. KITOZER recommends installing a separate maintenance bypass circuit so the set can be serviced while the building remains on utility power.
Packaging and Shipping
The open frame generator is wrapped in stretch film, protected with foam on gauges and alternator, and strapped to a fumigated steel skid with lifting eyes. KITOZER factory-load-banks every unit and provides a performance certificate before shipment. Export documents include CE certificate, factory test report, commercial invoice, packing list, and origin certificate. KITOZER can arrange container loading, CIF delivery, and engineer commissioning on site.
Quality Assurance and Warranty
Every KITOZER product undergoes a strict factory inspection process before shipment. The engine is run in and load-tested, the alternator winding resistance and insulation are measured, the control panel is functionally checked, and the complete set is operated under load bank for at least one hour. KITOZER provides a 12-month warranty from shipment or 1000 running hours, whichever comes first, covering manufacturing defects in engine, alternator, and control panel. Spare parts, filters, belts, and fuses are stocked for rapid dispatch. The KITOZER technical team provides remote troubleshooting support over email, WeChat, or WhatsApp, and can dispatch an engineer to site for critical projects.
KITOZER engineering can tailor the set to specific site conditions: cold climate kits with jacket water heater, oil pan heater, and battery blankets; tropical kits with larger radiator and desert-grade air filters; coastal kits with C5-M paint and anti-corrosion anodes; and emission-compliant kits for regulated markets. The factory also offers extended warranty, annual service contracts, and remote monitoring subscriptions that stream runtime, fuel level, and alarms to a cloud dashboard.
Price
From $18,500 per unit for the 120 kW open frame set. Contact KITOZER for engine brand options, alternator upgrade, AMF panel, and CIF delivery. Tel/WeChat: +86 13922289957.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com