ToggleProduct Overview
The KITOZER 128 point environment monitoring host is a central collector unit for data center, server room, electrical substation, warehouse, and clean room environmental monitoring projects. The host aggregates data from temperature, humidity, water leak, smoke, door contact, vibration, and power monitoring sensors distributed throughout a facility, and forwards the data to the KITOZER DCIM platform, building management system, or cloud dashboard over Ethernet. With support for up to 128 external monitoring points on a single unit, the host reduces the cost of multi-site deployments compared with using many small data loggers, and provides local alarm relay outputs that can trigger audio visual alarms or shut down ventilation equipment even when the central software is offline.
The host is built around a fanless industrial processor with wide-range 9 to 36 V DC power input, making it suitable for installation in electrical cabinets where supply voltage may fluctuate. A 3.5 inch color touch screen on the front panel allows local operators to view current readings, acknowledge alarms, and modify thresholds without a PC. On-board storage holds up to 1 million historical data records, and a built-in real-time clock with battery backup ensures timestamps remain accurate for at least three years without network time synchronization.
Technical Specifications
Processor fanless ARM Cortex-A7 industrial. Memory 512 MB RAM, 4 GB flash. Display 3.5 inch color touch screen, 320 by 480 resolution. Monitoring points: up to 128 points via cascaded RS485 expansion buses. On-board interfaces: 2 Ethernet 10/100 Mbps, 4 RS485 ports, 2 USB, 4 dry contact inputs, 4 relay outputs rated 2 A 30 V DC. Protocols: Modbus TCP server and client, Modbus RTU, SNMP v2c, MQTT, HTTP JSON, web HMI. Sensor support: temperature humidity, water leak rope, smoke, door contact, vibration, current transformer, voltage, door magnetic, infrared barrier. Power input 9 to 36 V DC, typical consumption 5 W. Operating temperature minus 20 degrees Celsius to 70 degrees Celsius, humidity 5 to 95 percent non-condensing. Enclosure metal wall mount, 160 by 110 by 40 millimeters. CE and FCC certified, three year warranty.
Application Scenarios
This monitoring host is installed in server room cabinets, telecom equipment shelters, electrical substations, battery rooms, cold storage warehouses, museum climate controlled galleries, pharmaceutical storage areas, and industrial control rooms. In a typical data center deployment, the host collects temperature and humidity readings from 20 sensors in the cold aisle, water leak rope readings along the CRAH unit perimeter, smoke detector states from the fire panel, and door contact status on the server room entrance. When a temperature exceeds the configured threshold, the host triggers the local buzzer, closes a relay to activate the ventilation fan, and sends an e-mail and push notification to the on-call engineer within three seconds. The host can also be used stand-alone in small sites where no central DCIM is deployed, logging data locally and sending alarm e-mails directly to the customer IT team.
Key Advantages
The first advantage is large point capacity on a single unit. 128 points means a typical 20 rack server room can be monitored by one host instead of four or five small data loggers, simplifying wiring and reducing spare-parts inventory. The second advantage is offline autonomy. Even if the Ethernet network to the central server is broken, the host continues to log readings locally, sound the buzzer, and operate alarm relays, so critical safety functions do not depend on network availability. The third advantage is multi-protocol output. The host speaks Modbus TCP, SNMP, and MQTT at the same time, so it can feed a legacy BMS over Modbus, a modern cloud platform over MQTT, and a local SCADA over SNMP without requiring a protocol gateway. The fourth advantage is local touch screen. Maintenance staff working inside a noisy server room can acknowledge an alarm or view a sensor reading directly on the host, without carrying a laptop or logging into a web page.
Installation and Maintenance Recommendations
Mount the host on a DIN rail or wall plate inside the monitoring cabinet, away from high-voltage contactors and variable frequency drives. Use shielded twisted pair for each RS485 bus, daisy-chain no more than 32 sensors per bus, and install a 120 ohm termination resistor at the farthest sensor on each bus. Assign a unique Modbus address to every sensor and record the address map in the project documentation. During commissioning, walk around the facility with the touch screen and verify that each sensor reading changes when a hand is held near the sensor, confirming that the wiring and address mapping are correct. Configure alarm thresholds with a 60 second delay to suppress momentary spikes from door openings. Schedule quarterly maintenance to check the real-time clock battery, verify that the buzzer still sounds during a test alarm, and export the local historical log for archive. Keep a backup of the configuration file on a USB drive after every sensor addition or threshold change.
Price
From $420 per unit, including power supply and mounting bracket. Contact +86 13922289957 for bundle pricing with sensors, cabling, and remote commissioning support.