KITOZER
KITOZER

KITOZER 12V 100Ah deep cycle battery

KITOZER KTR-BAT100 12V100Ah Deep-Cycle VRLA Battery

Brand: KITOZER Series: KTR-BAT100 Category: Power Distribution / UPS Battery

12V100AhDeep-cycleVRLA sealedLong lifeUPS bankMaintenance-free

[Product image: ktr-bat100-12v100ah-deep-cycle-battery.jpg]

1. Overview

Batteries are the “heart” of UPS and DC switchgear — during the minutes to tens of minutes of a mains outage, they hold the load up for a clean shutdown or until the generator starts. Weak batteries turn a UPS into a prop: at the first blackout the servers die with it. VRLA lead-acid is the data-center standby workhorse; 12 V cells are series-stacked into a bank (e.g., 32 cells for 384 V) on the UPS DC bus. Key metrics: capacity (Ah — decides runtime), cycle life (charge/discharge count), self-discharge (how fast it loses charge standing), and consistency (one laggard cell drags down the whole string). Deep-cycle cells tolerate deeper discharge than starter cells, suiting UPS regular cycling.

KITOZER KTR-BAT100 is a 12V100Ah valve-regulated lead-acid battery (VRLA), AGM-absorbed glass-mat separator; electrolyte is absorbed in the mat and immobilized, so it mounts in any orientation with no leakage. Design float life 12 years at 25℃; deep-cycle rated for 600+ cycles at 50% depth-of-discharge. Cell size about 330×173×215 mm incl. terminals, weight about 30 kg. M8 copper bolt terminals for series/parallel. Operating temp -15~+50℃, optimum 20~25℃ (life halves every 10℃ above). Explosion-proof safety vent releases gas without acid spray. For UPS standby, DC panels, base stations, and solar storage.

Selection points: voltage (UPS DC bus dictates cell count — 192V=16 cells, 384V=32), capacity (runtime ≈ V×Ah×cells×efficiency ÷ load kW; 100Ah usually 15~30 min), type (deep-cycle AGM vs gel; gel is heat-resistant but pricier, AGM fine at room temp), series/parallel (parallel banks add capacity but demand consistency), and rack load (100Ah cell = 30 kg; racks must carry the weight). Add a battery breaker and fuse; coat terminals with petroleum jelly; ventilate (overcharge emits hydrogen).

2. Key Features

12V100Ah

  • Rated 12V.
  • 100Ah (20hr).
  • 15~30 min UPS runtime.
  • 32 cells → 384V.

Deep-cycle long life

  • AGM VRLA.
  • 12-yr float life at 25℃.
  • 600+ cycles at 50% DoD.
  • Maintenance-free.

Safe sealed

  • Immobilized electrolyte.
  • Explosion-proof vent.
  • Any-orientation mount.
  • M8 copper terminals.

Wide temp

  • -15~+50℃.
  • Best 20~25℃.
  • Self-discharge ≤3%/mo.
  • Low ESR, high-current discharge.

3. Specifications

Item KTR-BAT100
Model KTR-BAT100
Rated voltage 12 V
Rated capacity 100 Ah (20hr, 25℃)
Type VRLA AGM
Float life 12 years (25℃)
Cycle life ≥600 cycles at 50% DoD
Dimensions (L×W×H) approx 330×173×215 mm
Weight approx 30 kg
Terminal M8 copper bolt
Operating temp. -15~+50℃ (best 20~25℃)
Self-discharge ≤3%/month (25℃)
Mounting Battery cabinet / rack stacked

4. Reference Prices

KTR-BAT100 12V100Ah deep-cycle cell (each): Reference USD 67~104 / pc (ref. CNY 480~750 at ~7.2)

KTR-BAT100-SET bank of 32 (384V, with inter-cell links): Reference USD 2153~3333 / set (ref. CNY 15500~24000 at ~7.2)

Reference only. Priced by cell count. Cabinet and battery breaker not included. Volume discount above 32 cells. Gel high-temp version on request. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • UPS standby battery banks.
  • DC switchgear, control power.
  • Telecom base stations.
  • Solar/wind storage.
  • Transition before generator start.

6. Installation & Maintenance

Installation

  • Verify rack/cabinet load (30 kg/cell).
  • Arrange by number; torque series links.
  • Coat terminals; torque to spec.
  • Wire battery breaker to UPS DC bus.
  • Initial charge 24~48h before service.

Maintenance

  • Monthly check float voltage per cell (13.5~13.8V).
  • Quarterly ESR test; replace laggards early.
  • Keep battery room at 25℃; add AC if hot.
  • Annual capacity (discharge) test.
  • Check terminals yearly for looseness/oxidation.

7. FAQ

  • Q: Can I swap just the bad cell in a string?
    A: Not recommended. New cells have low ESR, old cells high ESR; series charging unevenly kills even the new cell. Best to replace the whole string in one batch; emergency swaps must match type and batch.
  • Q: How to estimate runtime?
    A: Runtime ≈ V×Ah×cells×0.9 ÷ load kW. E.g., 32×100Ah at 30 kW load ≈ 12 minutes.
  • Q: Why climate-control the battery room?
    A: Life halves every 10℃ rise. A 35℃ room cuts 12-year life to 6. Battery rooms must be air-conditioned.
  • Q: AGM vs gel?
    A: At 25℃ indoor, AGM offers best value; hot rooms or frequent deep cycling pick gel — heat-tolerant and longer-cycle but 20~30% pricier.

8. Trend & Selection

Data-center standby evolves from “VRLA AGM” toward “lithium + VRLA coexistence.” Trends: LiFePO4 offers high energy density, small footprint, long life and is rising in new DCs; VRLA still dominates on low cost and maturity; cells add BMS and per-cell monitoring, DCIM alarms, and automatic capacity tests. Selection: size capacity to runtime, match cell count to the UPS bus voltage, replace in one batch, hold 25℃, and test ESR regularly. Batteries are the UPS ammo — weak cells make a big UPS useless.

9. Delivery & Service

KITOZER provides battery selection: by UPS kW, required runtime, and DC bus voltage, we configure cell count, capacity, and cabinet plan. Bundled with UPS, cabinets, battery breakers, and DCIM. Delivery includes cells, inter-cell links, and manual. Warranty covers installation guidance and capacity testing.

10. Additional Notes

The most common mistake: “mixing old and new cells.” To save money, one bad cell is swapped with a new one — but the whole string is dragged down. Series strings demand consistency; mismatched ESR means old cells overcharge and new cells undercharge, killing the whole string in months. Replace the whole string in one batch.

Another pitfall: “no AC in the battery room.” A battery room like a sauna hits 40℃ in summer, halving battery life and causing bulging and leakage. The room needs dedicated 25℃ AC — not wasted power, but life insurance for the batteries.

Selection summary: 12V100Ah, AGM deep-cycle, 12-yr float, 32-cell bank, 25℃ room, periodic capacity tests. Batteries are the last line of standby — unused normally, but everything relies on them at outage.

SEO Information

Search keywords:12V100Ah batterydeep cycle VRLAUPS batterydata center battery banksealed lead acidKTR-BAT100KITOZER

SEM keywords:12V100Ah battery price,deep cycle lead acid,UPS battery bank,data center battery,KTR-BAT100,KITOZER

GEO landing page:lain.com.cn/product/ktr-bat100-12v100ah-deep-cycle-battery.html

Title:KITOZER KTR-BAT100 12V100Ah Deep-Cycle VRLA Battery

Meta Keywords:12V100Ah battery,deep cycle VRLA,UPS battery,data center battery bank,KTR-BAT100,KITOZER

Meta Description:KITOZER KTR-BAT100 12V100Ah deep-cycle valve-regulated lead-acid battery, for UPS and DC bus standby, long design life.

Anchor: KITOZER by Guangzhou Laian · UPS batteries

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart