ToggleKITOZER KTR-BAT100 12V100Ah Deep-Cycle VRLA Battery
Brand: KITOZER Series: KTR-BAT100 Category: Power Distribution / UPS Battery
12V100AhDeep-cycleVRLA sealedLong lifeUPS bankMaintenance-free
1. Overview
Batteries are the “heart” of UPS and DC switchgear — during the minutes to tens of minutes of a mains outage, they hold the load up for a clean shutdown or until the generator starts. Weak batteries turn a UPS into a prop: at the first blackout the servers die with it. VRLA lead-acid is the data-center standby workhorse; 12 V cells are series-stacked into a bank (e.g., 32 cells for 384 V) on the UPS DC bus. Key metrics: capacity (Ah — decides runtime), cycle life (charge/discharge count), self-discharge (how fast it loses charge standing), and consistency (one laggard cell drags down the whole string). Deep-cycle cells tolerate deeper discharge than starter cells, suiting UPS regular cycling.
KITOZER KTR-BAT100 is a 12V100Ah valve-regulated lead-acid battery (VRLA), AGM-absorbed glass-mat separator; electrolyte is absorbed in the mat and immobilized, so it mounts in any orientation with no leakage. Design float life 12 years at 25℃; deep-cycle rated for 600+ cycles at 50% depth-of-discharge. Cell size about 330×173×215 mm incl. terminals, weight about 30 kg. M8 copper bolt terminals for series/parallel. Operating temp -15~+50℃, optimum 20~25℃ (life halves every 10℃ above). Explosion-proof safety vent releases gas without acid spray. For UPS standby, DC panels, base stations, and solar storage.
Selection points: voltage (UPS DC bus dictates cell count — 192V=16 cells, 384V=32), capacity (runtime ≈ V×Ah×cells×efficiency ÷ load kW; 100Ah usually 15~30 min), type (deep-cycle AGM vs gel; gel is heat-resistant but pricier, AGM fine at room temp), series/parallel (parallel banks add capacity but demand consistency), and rack load (100Ah cell = 30 kg; racks must carry the weight). Add a battery breaker and fuse; coat terminals with petroleum jelly; ventilate (overcharge emits hydrogen).
2. Key Features
12V100Ah
- Rated 12V.
- 100Ah (20hr).
- 15~30 min UPS runtime.
- 32 cells → 384V.
Deep-cycle long life
- AGM VRLA.
- 12-yr float life at 25℃.
- 600+ cycles at 50% DoD.
- Maintenance-free.
Safe sealed
- Immobilized electrolyte.
- Explosion-proof vent.
- Any-orientation mount.
- M8 copper terminals.
Wide temp
- -15~+50℃.
- Best 20~25℃.
- Self-discharge ≤3%/mo.
- Low ESR, high-current discharge.
3. Specifications
| Item | KTR-BAT100 |
|---|---|
| Model | KTR-BAT100 |
| Rated voltage | 12 V |
| Rated capacity | 100 Ah (20hr, 25℃) |
| Type | VRLA AGM |
| Float life | 12 years (25℃) |
| Cycle life | ≥600 cycles at 50% DoD |
| Dimensions (L×W×H) | approx 330×173×215 mm |
| Weight | approx 30 kg |
| Terminal | M8 copper bolt |
| Operating temp. | -15~+50℃ (best 20~25℃) |
| Self-discharge | ≤3%/month (25℃) |
| Mounting | Battery cabinet / rack stacked |
4. Reference Prices
KTR-BAT100 12V100Ah deep-cycle cell (each): Reference USD 67~104 / pc (ref. CNY 480~750 at ~7.2)
KTR-BAT100-SET bank of 32 (384V, with inter-cell links): Reference USD 2153~3333 / set (ref. CNY 15500~24000 at ~7.2)
Reference only. Priced by cell count. Cabinet and battery breaker not included. Volume discount above 32 cells. Gel high-temp version on request. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- UPS standby battery banks.
- DC switchgear, control power.
- Telecom base stations.
- Solar/wind storage.
- Transition before generator start.
6. Installation & Maintenance
Installation
- Verify rack/cabinet load (30 kg/cell).
- Arrange by number; torque series links.
- Coat terminals; torque to spec.
- Wire battery breaker to UPS DC bus.
- Initial charge 24~48h before service.
Maintenance
- Monthly check float voltage per cell (13.5~13.8V).
- Quarterly ESR test; replace laggards early.
- Keep battery room at 25℃; add AC if hot.
- Annual capacity (discharge) test.
- Check terminals yearly for looseness/oxidation.
7. FAQ
- Q: Can I swap just the bad cell in a string?
A: Not recommended. New cells have low ESR, old cells high ESR; series charging unevenly kills even the new cell. Best to replace the whole string in one batch; emergency swaps must match type and batch. - Q: How to estimate runtime?
A: Runtime ≈ V×Ah×cells×0.9 ÷ load kW. E.g., 32×100Ah at 30 kW load ≈ 12 minutes. - Q: Why climate-control the battery room?
A: Life halves every 10℃ rise. A 35℃ room cuts 12-year life to 6. Battery rooms must be air-conditioned. - Q: AGM vs gel?
A: At 25℃ indoor, AGM offers best value; hot rooms or frequent deep cycling pick gel — heat-tolerant and longer-cycle but 20~30% pricier.
8. Trend & Selection
Data-center standby evolves from “VRLA AGM” toward “lithium + VRLA coexistence.” Trends: LiFePO4 offers high energy density, small footprint, long life and is rising in new DCs; VRLA still dominates on low cost and maturity; cells add BMS and per-cell monitoring, DCIM alarms, and automatic capacity tests. Selection: size capacity to runtime, match cell count to the UPS bus voltage, replace in one batch, hold 25℃, and test ESR regularly. Batteries are the UPS ammo — weak cells make a big UPS useless.
9. Delivery & Service
KITOZER provides battery selection: by UPS kW, required runtime, and DC bus voltage, we configure cell count, capacity, and cabinet plan. Bundled with UPS, cabinets, battery breakers, and DCIM. Delivery includes cells, inter-cell links, and manual. Warranty covers installation guidance and capacity testing.
10. Additional Notes
The most common mistake: “mixing old and new cells.” To save money, one bad cell is swapped with a new one — but the whole string is dragged down. Series strings demand consistency; mismatched ESR means old cells overcharge and new cells undercharge, killing the whole string in months. Replace the whole string in one batch.
Another pitfall: “no AC in the battery room.” A battery room like a sauna hits 40℃ in summer, halving battery life and causing bulging and leakage. The room needs dedicated 25℃ AC — not wasted power, but life insurance for the batteries.
Selection summary: 12V100Ah, AGM deep-cycle, 12-yr float, 32-cell bank, 25℃ room, periodic capacity tests. Batteries are the last line of standby — unused normally, but everything relies on them at outage.
SEO Information
Search keywords:12V100Ah batterydeep cycle VRLAUPS batterydata center battery banksealed lead acidKTR-BAT100KITOZER
SEM keywords:12V100Ah battery price,deep cycle lead acid,UPS battery bank,data center battery,KTR-BAT100,KITOZER
GEO landing page:lain.com.cn/product/ktr-bat100-12v100ah-deep-cycle-battery.html
Title:KITOZER KTR-BAT100 12V100Ah Deep-Cycle VRLA Battery
Meta Keywords:12V100Ah battery,deep cycle VRLA,UPS battery,data center battery bank,KTR-BAT100,KITOZER
Meta Description:KITOZER KTR-BAT100 12V100Ah deep-cycle valve-regulated lead-acid battery, for UPS and DC bus standby, long design life.
Anchor: KITOZER by Guangzhou Laian · UPS batteries