1. Overview
When utility power fails, the UPS relies on its battery string to feed the load. Batteries are the UPS’s fuel tank — no matter how advanced the UPS, weak batteries mean shutdown the moment power drops. Data halls commonly use valve-regulated lead-acid (VRLA) batteries, divided into stationary (float service) and deep-cycle (repeated charge/discharge). Stationary batteries sit on float charge, discharging only on outage, staying fully charged; deep-cycle batteries are designed for repeated deep discharge (to 50% or lower) and recharge, with longer cycle life — suited to frequent outages or long backup runtime.
KITOZER KTR-BAT38 is a 12V 38Ah VRLA battery. Nominal 12V, rated 38Ah (20-hour rate). It uses AGM (absorbent glass mat) technology — electrolyte is absorbed in the glass mat, non-spill, non-leak, mountable in any orientation (upright recommended). Valve-regulated seal means normal operation produces no gas and needs no water topping — maintenance-free. Deep-cycle design withstands about 1200 cycles at 50% depth of discharge, versus about 300 cycles for a stationary battery at the same DoD. Design float life is 10 years at 25℃ ambient; actual life is temperature-sensitive — every 10℃ rise halves life.
Battery strings are built by series connection to reach the required voltage. For a 192V DC bus, 16 × 12V batteries in series (16×12=192V). The 38Ah size is commonly used for small-to-medium UPS (3~10 kVA) backup configurations. Strings are arranged in a battery cabinet or rack, series-connected with link bars, and the end connects to the UPS DC breaker. Selection depends on: backup runtime (discharge power × time = required capacity), string count (DC bus ÷ 12V), space (cabinet/rack tiers), ambient temperature (affects life) and brand consistency (same brand and batch in a string; never mix new and old).
2. Key Features
12V 38Ah deep cycle
- Nominal 12V, 38Ah (20hr).
- Deep-cycle design, ~1200 cycles at 50% DoD.
- Withstands deep discharge before recharge.
- Suits frequent-outage areas.
AGM VRLA
- AGM absorbed electrolyte.
- No spill, mountable any orientation.
- Normal operation no gas, maintenance-free.
- Safety valve controls pressure.
Long life
- 10-year float design life (25℃).
- Corrosion-resistant grid alloy.
- Low self-discharge (<3%/month).
- Operating temp -15~+50℃.
Safety & compatibility
- Flame-retardant case (UL94 V-0).
- Terminal leak-proof design.
- Compatible with mainstream UPS / DC panels.
- Built-in handle for handling.
3. Specifications
| Item | KTR-BAT38 |
|---|---|
| Nominal voltage | 12V |
| Rated capacity | 38Ah (20hr, 25℃) |
| Battery type | VRLA AGM deep-cycle |
| Dimensions (L×W×H) | 197×165×175 mm |
| Weight | ~12.5 kg |
| Terminal | M6 copper |
| Float voltage | 13.5~13.8 V/unit (25℃) |
| Equalize voltage | 14.4~14.7 V/unit |
| Charge current limit | ≤0.25C (~9.5A) |
| Design float life | 10 years (25℃) |
| 50% DoD cycles | ~1200 |
| Self-discharge | <3%/month (25℃) |
4. Reference Prices
KTR-BAT38 12V 38Ah deep-cycle (AGM, M6 terminals, 10-year design life): Reference USD 39~63 / unit (ref. CNY 280~450 at ~7.2)
Set of 16 (192V DC bus, incl. link bars): Reference USD 667~1,042 / set (ref. CNY 4,800~7,500 at ~7.2)
Reference only; tiered by quantity. Cabinet/rack and installation not included. Volume discount above 32 units. Old battery recycling quoted separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Small-to-medium UPS (3~10 kVA) backup.
- Telecom base stations, hall DC panel (-48V).
- Security and fire emergency power.
- Solar/wind off-grid storage.
- Emergency lighting, elevator backup.
6. Installation & Maintenance
Installation
- Upright in cabinet/rack; never invert.
- Same brand and batch in one string; no new/old mix.
- Series-connect with link bars (+ to -).
- Torque terminals to spec (8~10 N·m); coat with petroleum jelly against oxidation.
- End connects to UPS DC breaker (fuse on positive).
- Equalize after install; verify per-cell voltage balance.
Maintenance
- Monthly measure per-unit float voltage; if spread >0.05V, equalize.
- Quarterly measure internal resistance; rising resistance signals aging.
- Keep battery room 20~25℃, ventilated.
- Annually do a verification discharge (30%~50% depth).
- Check link bars for looseness/oxidation; terminals for leaks.
7. FAQ
- Q: Replace whole string after 5 years?
A: Check capacity. Run a verification discharge; if actual capacity <80% of nameplate, replace the whole string. Don't swap single units (new/old mismatch drags the string down). - Q: Why ventilate the battery room?
A: Lead-acid emits hydrogen at charge end (minimal in VRLA, but present); accumulation to 4% is explosive. Battery rooms need ≥12 ACH exhaust. - Q: Mix deep-cycle and stationary?
A: Not recommended. Charge curves and internal resistances differ; mixing causes overcharge on one and undercharge on the other. Same model per string. - Q: Effect of high temperature?
A: Every 10℃ rise roughly halves float life. At 35℃, a 10-year design life may drop to 4~5 years. Battery rooms must be temperature-controlled.
8. Trend & Selection
Data center backup is shifting from lead-acid to lithium (LiFePO4), but lead-acid remains mainstream in small/medium scenes due to maturity, low cost and recycling infrastructure. Deep-cycle lead-acid is steady-demand thanks to long cycle life in frequent-outage regions. Lithium trends: small (1/3 lead-acid volume), light (1/3), more cycles (>6000), BMS-managed — but higher upfront cost and recycling still maturing. For small UPS backup under 15 min, stationary is cheaper; long runtime or frequent outages choose deep-cycle; DC bus dictates string count (192V=16 units, 240V=20); size Ah by runtime (discharge power ÷ UPS efficiency ÷ battery voltage = current, then read discharge curve); keep battery room at 25℃; same brand/batch per string; annual verification discharge; torque link bars to prevent loosening.
9. Delivery & Service
KITOZER provides battery selection: based on UPS power, backup runtime and DC bus voltage, we calculate required Ah and string count. Bundled with UPS, battery cabinet and DC distribution box. Delivery includes battery body, link bars, terminal washers and manual. Warranty covers discharge test guidance.
10. Additional Notes
The most common hidden hazard is “measuring only total string voltage, not per-unit.” Operators record cabinet total voltage monthly (e.g. 192V), which looks fine — but one unit may already be weak. Total voltage is carried up by the good batteries; when the weak unit reaches end voltage first during discharge, the whole string’s runtime collapses. Must measure every unit’s voltage and internal resistance; replace weak units promptly.
Another pitfall: “mixing new and old batteries.” When expanding or replacing a few bad units, some swap only the dead one while keeping 5-year-old units. Old and new have different internal resistance — charging overcharges old before new is full; discharging empties new while old is already dead. String capacity is limited by the weakest old battery. Replace the whole string; don’t cling to residual value of old units.
Selection summary: deep-cycle for frequent outages; 12V 38Ah for small UPS; string count by DC bus; same brand/batch per string; measure per-unit voltage and resistance; battery room temp-controlled and ventilated; replace whole string, don’t mix. Batteries are the UPS fuel tank — they carry the runtime in critical moments; measuring one extra voltage reading now saves risk later.
SEO Information
Search keywords:battery12V 38Ahdeep cycleVRLA sealedUPS batterymaintenance-freeKTR-BAT38KITOZER
SEM keywords:12V 38Ah battery price,deep cycle battery supplier,UPS backup battery,VRLA battery,KTR-BAT38,KITOZER
GEO landing page:lain.com.cn/product/ktr-bat38-12v38ah-deep-cycle-battery.html
Title:KITOZER KTR-BAT38 12V 38Ah Deep-Cycle VRLA Battery
Meta Keywords:battery,12V 38Ah,deep cycle,VRLA,UPS battery,sealed lead acid,KTR-BAT38,KITOZER
Meta Description:KITOZER KTR-BAT38 12V 38Ah sealed valve-regulated lead-acid deep-cycle battery, 10-year float design life, for UPS, DC panel and telecom backup.