ToggleKITOZER KTR-BAT65 12V65Ah Deep-Cycle Battery
Brand: KITOZER Series: KTR-BAT65 Category: Power Distribution / UPS Batteries
12V65AhDeep-cycleVRLA sealedLead-acid batteryUPS backupMaintenance-free
1. Overview
The UPS relies on its battery bank to carry the load when grid power fails. Batteries are the UPS’s energy warehouse — floating on standby, discharging immediately on outage. A typical data center strings 32 × 12 V batteries into a 384 V DC bus, backing the UPS at full load for 15~30 minutes. Battery capacity and health directly determine backup time: aged cells may deliver 30 Ah of a rated 65 Ah, halving backup and dropping the load within minutes of outage. Deep-cycle cells tolerate deeper discharge (50%~80%) and longer cycle life than starter (shallow-cycle) cells, suiting UPS “long-float, occasional-discharge” duty.
KITOZER KTR-BAT65 is a 12V65Ah VRLA sealed lead-acid battery. ABS flame-retardant case, internal AGM absorbed-glass-mat separator (electrolyte absorbed in fiber, no spillage), valve-regulated (safety valve vents at pressure, otherwise sealed). Rated 12 V (six cells in series), 65 Ah (20-hour rate, 25℃). Float design life 5 years (25℃), deep-cycle design, discharge depth up to 80%. M8 bolt terminals, vent valve. Operating temp -15~+50℃ (best at 25℃). Dimensions approx 350×166×175 mm (L×W×H), weight about 20 kg.
Selection points: voltage (12 V unit; string count by UPS DC bus), capacity (65 Ah maps to backup time — back-calculate from load power and target backup), cycle type (deep-cycle for UPS; starter cells unsuitable for deep discharge), design life (5-year standard vs 10-year long-life; halls recommend long-life), temperature (high heat ages cells; battery room must stay 25℃), and brand consistency (same bank must be same brand and batch — no mixing). Note a battery bank is a “wooden barrel” — the weakest cell sets bank capacity; periodically identify and replace lagging cells.
2. Key Features
Deep-cycle design
- Discharge depth up to 80%.
- Cycle life ≥1200 times (50% DOD).
- Suits UPS charge/discharge.
- Thicker plates.
VRLA sealed
- AGM absorbed separator.
- No spill, no watering.
- Valve-regulated venting.
- Mount any orientation (except tilt).
Long float life
- 5-year design at 25℃.
- 10-year long-life option.
- Low self-discharge.
- Stable float voltage.
Safe & reliable
- ABS flame-retardant case.
- M8 bolt terminals.
- Built-in temp compensation.
- Overcharge protection.
3. Specifications
| Item | KTR-BAT65 |
|---|---|
| Model | KTR-BAT65 |
| Nominal voltage | 12 V (6 cells) |
| Nominal capacity | 65 Ah (20h rate, 25℃) |
| Battery type | VRLA AGM lead-acid |
| Float life | 5 years (25℃) |
| Cycle life | ≥1200 times (50% DOD) |
| Float voltage | 13.5~13.8 V (25℃) |
| Equalize voltage | 14.4~14.9 V |
| Terminal | M8 bolt |
| Operating temp. | -15~+50℃ |
| Dimensions | Approx 350×166×175 mm |
| Weight | Approx 20 kg |
4. Reference Prices
KTR-BAT65 12V65Ah deep-cycle VRLA battery (5-year design, M8 terminals): Reference USD 67~104 / pc (ref. CNY 480~750 at ~7.2)
KTR-BAT65L 10-year long-life version (with terminal guards): Reference USD 90~132 / pc (ref. CNY 650~950 at ~7.2)
Reference only; tiered per whole bank (typically 32 pcs+). Battery cabinet and installation not included. Volume discount above 32 pcs. Old-battery recycling credit available. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- UPS battery banks.
- Data center DC panel / operating power.
- Telecom base station backup.
- EPS emergency power.
- Off-grid PV storage.
6. Installation & Maintenance
Installation
- Inspect on unboxing (no swelling, no leak).
- Layer in cabinet with ≥10 mm spacing for cooling.
- Series-connect per drawing (M8 bolts, 8 N·m torque).
- Verify polarity before connecting; avoid shorts.
- Bank charge/discharge test; record initial voltages.
Maintenance
- Monthly measure per-cell float voltage (laggard <13.3 V).
- Keep battery room 20~25℃ (life halves per +10℃).
- Annual verification discharge (30%~50% capacity).
- Tighten connection bolts (thermal cycling loosens).
- Replace swollen/leaking cells immediately.
7. FAQ
- Q: Can I mix brands in one bank?
A: No. Different brands have different internal resistance and capacity; some over-charge, others under-charge, shortening bank life. Same brand and batch only. - Q: Can I keep using a swollen battery?
A: No. Swelling means internal short or overcharge — leak and fire risk. Isolate and replace immediately. - Q: How to calculate backup time?
A: Time ≈ capacity (Ah) × DC bus voltage × inverter efficiency ÷ load (kW). 65 Ah × 384 V × 0.95 ÷ load ≈ available time. - Q: What signals end-of-life?
A: Discharge test capacity below 80% of rated; float-voltage spread widens; individual cells clearly lag.
8. Trend & Selection
Banks evolve from “VRLA” toward “lithium + smart battery management.” Trends: LFP lithium penetrates large data centers (longer life, smaller footprint), but small UPS still favor VRLA; cells with BMS and per-cell monitoring (RS485/Modbus to DCIM), battery cabinets with AC and smoke detection, and second-life EV batteries trialed in storage. Selection: small UPS choose 12 V VRLA (mature, cheap); large new halls may evaluate LFP; keep room at 25℃; same brand and batch; monthly per-cell voltage; annual verification discharge; replace laggards promptly. Batteries are the UPS’s heart — a healthy bank carries through until the generator starts.
9. Delivery & Service
KITOZER provides battery selection: from UPS kW, target backup time, and DC bus voltage, we back-calculate capacity and string count. Bundled with UPS, battery cabinets, and DCIM battery monitoring modules. Delivery includes battery bodies, inter-cell links, terminal guards, and manual. Warranty covers charge/discharge testing guidance and laggard-cell identification.
10. Additional Notes
The most common fault: “battery room not temperature-controlled.” At 35℃ in summer, VRLA life halves per +10℃; a 5-year design life may die in 2 years. The battery room must have AC holding 25℃ year-round — the cheapest life-extension investment.
Another pitfall: “no verification discharge for years.” Some trust float voltage as health, but normal float voltage does not mean normal capacity — a sulfated cell may read normal float yet collapse on discharge. Run an annual verification discharge to measure real capacity and true backup time.
Selection summary: 12V65Ah deep-cycle VRLA; same brand/batch in series; room at 25℃; monthly per-cell voltage; annual verification discharge; replace laggards; isolate swollen cells immediately. Batteries are the UPS’s last line — if you only check them when the grid fails, it’s already too late.
SEO Information
Search keywords:12V65Ah batterydeep-cycle lead-acidUPS battery bankVRLA sealed batterymaintenance-free batterydata center powerKTR-BAT65KITOZER
SEM keywords:12V65Ah battery price,deep-cycle battery,UPS battery bank,VRLA battery,KTR-BAT65,KITOZER
GEO landing page:lain.com.cn/product/ktr-bat65-12v65ah-deep-cycle-ups-battery.html
Title:KITOZER KTR-BAT65 12V65Ah Deep-Cycle Battery
Meta Keywords:12V65Ah battery,deep-cycle,VRLA lead-acid,UPS backup battery,KTR-BAT65,KITOZER
Meta Description:KITOZER KTR-BAT65 12V65Ah deep-cycle VRLA sealed lead-acid battery, 5-year float design life, for UPS backup and DC panels.
Anchor: KITOZER by Guangzhou Laian · UPS battery banks
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com