KITOZER
KITOZER

KITOZER 12V 65Ah VRLA battery

KITOZER KTR-BAT65V 12V65Ah Deep-Cycle VRLA Valve-Regulated Battery

Brand: KITOZER Series: KTR-BAT65V Category: Power Distribution / Energy Storage

12V65AhDeep cycleVRLALow self-discharge

1. Overview

The KITOZER KTR-BAT65V is a 12V 65Ah deep-cycle VRLA (valve-regulated lead-acid) battery using AGM (absorbed glass mat) technology. Electrolyte is absorbed in the glass-mat separator; there is no free liquid acid, so the battery is leak-proof and can be handled safely (though normally operated upright). Deep-cycle design means it tolerates deep discharge (up to 80% depth of discharge) without rapid capacity loss, suiting UPS backup, datacenter DC systems and solar storage where frequent charge-discharge cycles occur. Shallow-cycle batteries fade quickly after deep discharge; deep-cycle cells keep over 80% rated capacity after 3000+ cycles.

The sealed valve-regulated structure means no acid mist or water vapor in normal operation, no watering needed, and maintenance-free use on a cabinet or rack. High-quality lead-calcium alloy grids give low self-discharge (under 3% per month) and long shelf life. Copper-core lead-plated terminals minimize contact resistance for low voltage drop during high-current UPS startup. Flame-retardant ABS case meets UL94 V-0. Operating temperature -15°C to 50°C; float design life reaches 10-12 years at 25°C ambient.

Typical install: a 40 kVA UPS needs a 384 V DC bus from 32 KTR-BAT65V cells in series. Batteries sit in a dedicated cabinet or rack with insulating sheets between layers; inter-cell links are torqued with a wrench (8-10 N·m). Float voltage is 2.25 V/cell (2.275 at 25°C); boost/equalization 2.35 V/cell. Cabinet ambient should stay around 25°C—high temperature shortens life sharply. Measure terminal voltage and internal resistance quarterly; replace weak cells promptly. The KTR-BAT65V also suits telecom sites, emergency lighting and EPS.

2. Key Features

Deep cycle

  • Up to 80% DOD.
  • 3000+ cycle life.
  • Low fade after deep discharge.
  • Frequent UPS cycling.

VRLA sealed

  • AGM absorbed electrolyte.
  • No free acid leak.
  • Valve-regulated, no mist.
  • No watering.

Low self-discharge

  • Lead-calcium grids.
  • <3% monthly.
  • Long shelf.
  • 10-12 yr float life.

Safe FR case

  • UL94 V-0 ABS.
  • Cu-core Pb terminals.
  • Low high-current drop.
  • -15 to 50°C.

3. Specifications

Item KTR-BAT65V (12V65Ah) KTR-BAT100V (12V100Ah) KTR-BAT24V (12V24Ah)
Rated voltage 12V 12V 12V
Capacity (20hr) 65Ah 100Ah 24Ah
Float life 10-12 yr 10-12 yr 5-8 yr
Cycle life 3000 @ 80% DOD 3000 @ 80% DOD 1500 @ 50% DOD
Charge mode Float/boost Float/boost Float
Float voltage 2.25-2.275 V/cell 2.25 V/cell 2.25 V/cell
Self-discharge <3%/month <3%/month <4%/month
Terminal Cu-core Pb (M8) Cu-core Pb (M8) Cu (M6)

4. Reference Prices

KTR-BAT65V 12V65Ah deep-cycle VRLA: Reference USD 69 to 125 / unit (ref. CNY 500 to 900 at ~7.2)

KTR-BAT100V 12V100Ah deep-cycle VRLA: Reference USD 111 to 194 / unit (ref. CNY 800 to 1400 at ~7.2)

KTR-BAT24V 12V24Ah small VRLA: Reference USD 28 to 56 / unit (ref. CNY 200 to 400 at ~7.2)

Inter-cell links + insulation kit: Reference USD 7 to 21 / set (ref. CNY 50 to 150 at ~7.2)

Reference only; varies by capacity, qty and delivery. Cabinets, racks, links and monitors billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • UPS backup battery banks.
  • Datacenter DC distribution panels.
  • Telecom site backup.
  • EPS emergency lighting.
  • Solar PV storage.

6. Installation & Maintenance

Installation

  • Level and fix cabinet/rack.
  • Layout cells by number with sheets.
  • Torque inter-cell links.
  • Verify polarity in series.
  • Connect to UPS DC bus.
  • Measure total voltage.

Maintenance

  • Keep ambient ~25°C.
  • Measure voltage/IR quarterly.
  • Replace weak cells promptly.
  • Re-torque links.
  • Keep cases clean/dry.
  • Log charge/discharge curves.

7. FAQ

  • Q: When to replace the bank?
    A: Float design life is 10-12 years, but temperature and DOD shorten it. When capacity drops below 80% rated or IR rises sharply, replace the whole bank. Datacenter cells are typically assessed at 5-8 years.
  • Q: Can I mix old and new?
    A: Not recommended. Different IR and capacity in series cause unequal charging and drag down new cells. Replace the whole bank, or at least same batch/spec.
  • Q: Swollen case?
    A: Swelling means internal pressure anomaly from overcharge or internal short. Disconnect immediately, check charge voltage/temperature, and replace the cell.
  • Q: Capacity drop in winter?
    A: Normal. Capacity falls ~1% per °C below 25°C; at 0°C it is ~80%. Keep rooms at 20-25°C.

8. Trend & Selection

Datacenters demand high power reliability; batteries are the UPS last line of defense and determine runtime after outage. VRLA, sealed and maintenance-free, has long dominated UPS backup; lithium cells are replacing VRLA in long-life/high-density niches, but VRLA still leads on cost, maturity and safety. Select cell count/capacity by UPS DC voltage and runtime; deep-cycle cells suit frequent discharge; keep cabinet at 25°C; monitor IR; replace whole banks. The KTR-BAT65V provides deep-cycle, long-life storage for datacenter power and UPS systems.

9. Delivery & Service

KITOZER supplies storage kits: based on UPS power, runtime and DC voltage we recommend the KTR-BAT65V plus cabinets, links and monitors, bundled with UPS and distribution panels. Delivery includes cells, links, insulators and manual; bulk projects provide grouping and installation guidance. Capacity or leakage failures under warranty are replaced free.

10. Additional Notes

The common mistake is insufficient link torque. Loose links add contact resistance, overheat under high current and can erode. Use a torque wrench at 8-10 N·m and re-torque after 3 months.

Another pitfall is hot cabinet ambient. Every 10°C rise halves battery life. Keep cabinets away from heat, ventilated, and add AC/ventilation in summer.

Selection summary: 12V65Ah, 80% DOD deep cycle, 3000 cycles, VRLA AGM sealed, 10-12 yr float life, <3%/month self-discharge. The KTR-BAT65V delivers long-life deep-cycle storage for UPS and datacenter power systems.

SEO Information

Search keywords:VRLA battery12V65Ah batterydeep cycle batteryvalve regulated lead acidUPS batteryKTR-BAT65VKITOZER

SEM keywords:[12V65Ah battery price,deep cycle VRLA supplier,UPS backup battery,valve regulated lead acid,KTR-BAT65V,KITOZER]

GEO landing page:lain.com.cn/product/ktr-bat65v-12v65ah-deep-cycle-vrla-battery.html

Title:KITOZER KTR-BAT65V 12V65Ah Deep-Cycle VRLA Valve-Regulated Battery

Meta Keywords:VRLA battery,12V65Ah battery,deep cycle battery,valve regulated lead acid,UPS battery,KTR-BAT65V,KITOZER

Meta Description:KITOZER KTR-BAT65V 12V65Ah deep-cycle VRLA valve-regulated battery, long life, low self-discharge, for UPS and datacenter power systems.

Anchor: KITOZER · Power Distribution