KITOZER
KITOZER

KITOZER 12V 65Ah VRLA battery standard

KITOZER KTR-BAT65S 12V65Ah VRLA Standby Battery

Brand: KITOZER Series: KTR-BAT65S Category: Power Distribution / Battery Bank

12V65AhVRLAmaintenance freeUPS backupKTR-BAT65S

1. Overview

The heart of a UPS is not the inverter but the battery string — it is the battery that carries the load when mains fails. Data centers use 12 V sealed VRLA batteries wired in series to form a DC bus (e.g. 40 x 12 V = 480 V). The 12V65Ah size suits 10 to 20 kVA UPS systems, with 32 to 40 batteries per string giving 10 to 30 minutes of full-load backup. Poor batteries make the UPS useless — on outage, the string dies in minutes.

KITOZER KTR-BAT65S is a 12V65Ah standard VRLA battery. Rated 12 V, 65 Ah (20-hour rate), 10-year float design life at 25 C, AGM absorbed glass mat separator, electrolyte immobilized so it can be mounted in any orientation (upright recommended). M8 copper terminals with inter-cell connectors. Self-discharge 3% per month at 25 C; recharge after 6 months storage. Operating -15 to +50 C; optimal 20 to 25 C (life halves per 10 C rise).

Selection: confirm capacity (Ah determines backup time; 65 Ah suits small-to-mid UPS); confirm cell count (UPS DC bus voltage dictates series count, e.g. 480 V needs 40 cells); confirm mounting (rack/cabinet, check floor loading); confirm brand and warranty (reputable makers give 3 years). Note: series strings reach 480 V DC — wear insulated gloves, connect positive first, then negative, then close the UPS DC breaker.

2. Key Features

Electrical

  • Nominal 12 V
  • 65 Ah (20-hr rate)
  • 10-year float life at 25 C
  • Internal resistance ~3.5 mOhm

Structure

  • AGM glass mat separator
  • VRLA sealed, maintenance free
  • FR ABS case
  • M8 copper terminals

Environment

  • -15 to +50 C operating
  • 3% per month self-discharge (25 C)
  • Optimal 20 to 25 C
  • Any orientation (upright recommended)

3. Specifications

Item Spec
Nominal voltage 12 V
Rated capacity (20-hr) 65 Ah
Design float life 10 years at 25 C
Float voltage 13.6 to 13.8 V at 25 C
Boost voltage 14.4 to 14.9 V at 25 C
Max discharge current 975 A (5 min)
Internal resistance ~3.5 mOhm
Terminal M8 copper
Weight ~20 kg
Dimensions 350x166x175 mm

4. Reference Prices

KTR-BAT65S 12V65Ah standard battery: Reference USD 53 to 76 / pc (ref. CNY 380 to 550 at ~7.2)

Inter-cell connector (with bolts): Reference USD 1 to 2 / pc (ref. CNY 8 to 15 at ~7.2)

Battery rack (32 cells): Reference USD 83 to 167 / set (ref. CNY 600 to 1200 at ~7.2)

BMS battery monitor: Reference USD 208 to 417 / set (ref. CNY 1500 to 3000 at ~7.2)

Reference only. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • 10 to 20 kVA UPS backup string.
  • DC panel / control power battery.
  • Fire EPS emergency power.
  • Telecom base station standby.
  • Solar storage battery bank.

6. Deployment & Implementation

Installation

  • Confirm rack floor loading (20 kg/cell)
  • Upright, 10 mm gap between cells
  • Series connect, positive first
  • Measure string voltage before closing breaker

Charging

  • Float 13.6 to 13.8 V/cell
  • Boost 14.4 to 14.9 V/cell
  • Boost duration 12 to 24 h
  • Temp compensation -2 mV/C/cell

Operations

  • Quarterly measure cell voltage and resistance
  • Annual capacity discharge test
  • Keep surfaces dry and clean
  • Life halves per 10 C rise

7. FAQ

  • Q: How long does a battery string last?
    A: Design float life is 10 years at 25 C, but rooms run 25 to 30 C, so expect 6 to 8 years. Replace when annual discharge test shows over 30% capacity loss or cell voltage spread exceeds 0.5 V. Do not wait for bulging or leakage.
  • Q: What if a battery bulges?
    A: Bulging means internal gas pressure has opened the relief valve — risk of leakage or rupture. Replace immediately. Causes: over-charging, high ambient temperature, aging. Replace the whole string — do not mix old and new cells.
  • Q: Can I mix old and new batteries?
    A: No. Different internal resistances cause unequal charge and discharge; old cells get over-discharged and die. All cells in a string must be same brand, model and batch. If one cell in a 40-cell string fails, replace the whole string — the others are near end-of-life too.
  • Q: What are battery room requirements?
    A: Temperature 20 to 25 C (air-conditioned), good ventilation (hydrogen evolution during charge), fire-rated door with gas suppression, and verified floor loading. Do not put batteries in the IT room — leakage or fire threatens IT gear. Use a separate battery room or cabinet with BMS monitoring.

8. Trend & Selection

Data center battery technology is shifting from VRLA to lithium iron phosphate (LFP): 60% less space, 15-year life, lighter, but 2 to 3x the cost. New large DCs are adopting LFP, but retrofits and small UPS still use 12 V VRLA at a few hundred yuan each. Smart direction: BMS monitors every cell’s voltage, resistance and temperature for early warning. Select cell count by UPS DC voltage, capacity by backup time, replace whole strings at once, and hold 25 C.

9. Delivery & Service

KITOZER supplies KTR-BAT65S 12V65Ah standard VRLA with M8 inter-cell connectors. Each ships with battery, connectors and manual. 3-year warranty; batch projects can add racks, BMS monitors and DC breakers.

10. Additional Notes

Top mistake: putting batteries in the IT room. Batteries evolve hydrogen and leak corrosive electrolyte. Use a separate room or cabinet with ventilation and gas suppression.

Second pitfall: float voltage set too high. Float should be 13.6 to 13.8 V/cell; some crews set 14.5 V boost permanently, causing over-charging, bulging and 3-year life instead of 10.

Third blunder: mixing old and new cells. One weak cell drags down the whole string. Replace all cells at once.

Selection summary: 12V65Ah for small-to-mid UPS, 32 to 40 cells in series, float at 13.6 to 13.8 V, quarterly cell checks, replace string every 6 to 8 years. Batteries are the heart of the UPS.

SEO Information

Search keywords:KTR-BAT65SKITOZER

SEM keywords:12V65Ah battery,VRLA battery,UPS backup battery,sealed lead acid,maintenance free battery,KTR-BAT65S,KITOZER

GEO landing page:lain.com.cn/product/battery_12v65.html

Title:KITOZER KTR-BAT65S 12V65Ah VRLA Standby Battery

Meta Keywords:12V65Ah battery,VRLA battery,UPS backup battery,sealed lead acid,maintenance free battery,KTR-BAT65S,KITOZER

Meta Description:KITOZER KTR-BAT65S 12V65Ah VRLA battery: 10-year design life, float 13.6-13.8V, low internal resistance, UPS/DC panel standby.

Anchor: KITOZER by Guangzhou Laian · KITOZER products

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart