Table of Contents
ToggleProduct Overview
The KITOZER 15kW downflow air-cooled precision air conditioner is engineered for small server rooms, network closets, telephone exchanges, and laboratory environments where stable temperature and humidity must be maintained 24 hours per day, 365 days per year. Unlike commercial comfort air conditioners that cycle frequently and suffer from humidity drift, this precision unit delivers tightly controlled supply air at 23 degrees Celsius plus or minus 1 degree and relative humidity at 50 percent plus or minus 5 percent. The downflow configuration discharges conditioned air into the raised floor plenum, which then distributes cooling through perforated tiles directly into the IT equipment inlets. A hermetic scroll compressor, electronically controlled expansion valve, EC plug fan, and integrated steam humidifier form the core refrigeration and moisture control loop. The cabinet uses double-skin galvanized steel panels with 50 mm injection foam insulation to prevent external condensation and reduce transmitted noise to surrounding offices.
Technical Specifications
Cooling capacity is rated at 15 kW nominal at standard data center conditions of 23 degrees Celsius dry bulb and 50 percent relative humidity. The unit operates on three phase 400 V plus neutral at 50 Hz, with a maximum electrical input of 5.2 kW. The air-cooled condenser is installed outdoors and connected by refrigerant piping up to 30 meters equivalent length, with a vertical lift allowance of 15 meters. Supply air volume is 3800 cubic meters per hour against a static pressure of 120 Pa. The humidifier is a 5 kW steam electrode type capable of adding 5 kg per hour of moisture. Electrical protection reaches IP20 inside the room cabinet, while the outdoor condenser is IP54. The controller provides a 7 inch color touch screen, trend logging for temperature and humidity, and 500 event alarm history. Refrigerant charge uses R410A, and the unit weighs approximately 280 kg. Optional accessories include a condensate lift pump, a post-heating electric coil, and a SNMP network card.
Application Scenarios
This 15 kW model suits equipment rooms hosting 5 to 10 server racks, network operation centers, broadcasting and television transmission rooms, small financial trading nodes, and outpatient medical imaging rooms. It is also commonly deployed in industrial automation control rooms, railway signal equipment rooms, subway traffic control cabinets, and university computer laboratories where heat density remains below 3 kW per rack. The downflow layout pairs naturally with raised floors of 400 mm or higher, while flexible ducting can redirect airflow to ceiling plenums where raised floors are absent. The unit is equally suitable for retail chain back-office server closets, government branch-office IT rooms, and small emergency call dispatch centers.
Advantages and Features
The unit maintains temperature stability within plus or minus 1 degree and humidity within plus or minus 5 percent, protecting sensitive electronics from both thermal throttling and electrostatic discharge. Inverter fan speed modulation matches airflow to instantaneous load, reducing energy waste during partial IT utilization. The EC fans consume up to 30 percent less power than traditional AC forward-curved fans. N plus 1 redundancy can be achieved by pairing two 15 kW units on sequenced control, where the controller automatically rotates duty hours and takes over on alarm. Condensate management, drip-tray heaters, and freeze protection ensure reliable operation across a wide ambient envelope. Remote monitoring via Modbus TCP, SNMP, or dry contacts integrates the unit with building management and DCIM platforms. The front-hinged doors allow single-person filter replacement without disturbing adjacent racks.
Installation and Maintenance Recommendations
Site preparation should include a level concrete or anti-vibration pad, adequate clearance of 800 mm at the front and 600 mm at the rear for service, and a dedicated refrigerant line routed with proper slope and insulation. The outdoor condenser must be installed in a well-ventilated location away from direct sunlight and recirculation of hot exhaust air. A condensate drain trap sized at DN25 should slope toward a floor drain. Filter inspection is recommended every 90 days and replacement every 12 months. The compressor, expansion valve, and humidifier cylinder should be inspected annually by certified service personnel. Spare filters, fuses, and a humidifier cylinder are recommended as on-site spares to minimize mean time to repair. A preventive maintenance contract with quarterly visits is recommended for mission-critical rooms.
Energy and Environmental Performance
Because the unit runs 24 hours per day, even small efficiency gains compound into large annual savings. EC fans, an inverter-controlled scroll compressor, and electronic expansion valve combine to deliver an energy efficiency ratio above 3.0 under part-load conditions, outperforming fixed-speed comfort units by 25 percent or more. R410A refrigerant has zero ozone depletion potential, and the cabinet is fully recyclable at end of life. The unit qualifies for most green-building rating schemes targeting low-energy IT facilities.
Price
From $6,880 per unit including indoor unit, outdoor condenser, controller, and standard accessories. Contact plus 86 13922289957 for factory quotation and lead time.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com