The KITOZER 16-string 1000V DC photovoltaic combiner box is engineered to consolidate multiple PV array strings into a single protected DC feed before the solar inverter. Designed for commercial rooftop and distributed ground-mount plants, the enclosure brings string fusing, surge protection, DC disconnection, and optional string current monitoring into one NEMA 4 rated housing. By centralizing protection and monitoring at the array side, installers reduce wiring runs, simplify commissioning, and give operators a clear point of isolation for maintenance crews working on the roof or ground.
Table of Contents
ToggleProduct Overview
KITOZER designs and manufactures the combiner box around a modular interior that accepts up to sixteen 1000V DC string inputs. Each input passes through a high-speed PV-rated fuse holder, a molded DC disconnect switch, and a transient voltage surge suppressor rated for Type II DC application class. The main output is a pre-torqueable copper busbar feeding a set of large cross-section DC cables routed to the inverter. An optional string monitoring kit clamps hall-effect sensors around each string, feeding a local display and a Modbus RTU port so operators can see per-string current, voltage, and temperature from the SCADA room. The cabinet is powder-coated steel with a gasketed door, lockable handle, and grounding busbar sized for the full short-circuit duty of the array.
Technical Specifications
Maximum system voltage is 1000V DC, with 16 string inputs rated for 15A continuous per channel. String fuses are gPV type, 15A, 1000V, UL 2579 recognized. The main DC disconnect is a load-break switch rated 250A, 1000V DC, with padlockable handle. Surge protection devices are Type II, 1000V DC, 40kA nominal discharge current, with dry-contact failure indication. Optional string monitors measure 0 to 20A per channel with 1 percent accuracy, communicate over RS485 Modbus RTU at 9600 to 115200 baud. Enclosure rating is NEMA 4 / IP65, suitable for outdoor rooftop installation. Operating temperature range is minus 35 degrees to plus 70 degrees Celsius. Certification includes IEC 61439, IEC 62619 for PV combiner safety, and CE marking. KITOZER provides a five-year factory warranty.
Application Scenarios
This combiner box is deployed on commercial rooftop arrays between 200kW and 2MW, where strings are spread across multiple roof sections and need a consolidation point before the central or string inverter. It is also used in distributed ground-mount carport systems and agricultural PV installations where the inverter must be located away from the array to avoid shade or flooding risk. Solar EPC contractors value it for rapid skid assembly: pre-wired combiners ship to site, and installers only land the string home runs and the inverter output cables. Microgrid and hybrid projects reuse the same enclosure for battery-side DC grouping when a secondary bus is needed between the rack PCS and the battery cluster.
Key Advantages
The KITOZER combiner box shortens installation labor because every fuse, SPD, and terminal is pre-torqued and labeled at the factory. String-level monitoring reveals underperforming modules so cleaning or replacement can be scheduled before revenue loss accumulates. The NEMA 4 housing survives coastal salt spray, desert dust, and heavy rain without extra sealing kits. Compared with on-roof field-combined junction boxes, the centralized design eliminates dozens of small, weather-exposed connections that are the most common source of DC arc faults. The Modbus port integrates the combiner into the plant SCADA alongside the inverter and meteorological station, giving operators a single view of DC health.
Installation and Maintenance
Mount the combiner box on a concrete plinth or roof standoff at least 30 centimeters above the expected snow or flood line, and orient the door away from direct midday sun to reduce internal heat. Torque all DC cable lugs to the value printed on the busbar, and verify continuity of the grounding path with a microhmmeter before energizing. On annual maintenance visits, inspect SPD status windows, measure insulation resistance on each string, and test the DC disconnect under no-load. Replace fuses with gPV-rated spares only, and do not mix DC and AC spares in the same drawer. Keep the door gasket clean and lightly greased, and retorque main busbar bolts every two years.
Quality, Warranty and Delivery
Every KITOZER combiner box undergoes a 100 percent factory test before shipment, including a high-potential insulation test on each string circuit, a torque verification on every busbar joint, and a functional check of the SPD status contacts and the string monitor Modbus loop. The shipment includes a stamped factory test report, a full-size wiring diagram, a quick-start commissioning checklist, and a small set of spare gPV fuses matched to the project rating. Cabinets are packed in a fumigated wooden crate with desiccant and a moisture barrier, suitable for sea freight and for stacking two crates high in a 20-foot container. Standard lead time is four to five weeks after the drawing is approved, and KITOZER can hold stock for repeat orders on large plants. The five-year warranty covers material and workmanship defects, and excludes damage caused by operation outside the specified voltage range, by unauthorized modification, or by improper lifting. KITOZER keeps spare fuse holders, SPD modules, and communication boards available for at least ten years after the last unit ships, so owners do not face obsolescence risk during the 25-year life of the PV plant.
Configuration and Ordering. KITOZER supplies each unit with the options specified at order placement, including the communication protocol, protection level, mounting orientation, and labeling language. Optional accessories such as external disconnect switches, surge protection kits, spare fuse sets, wall brackets, and remote monitoring gateways are available at a discount when ordered together with the main unit. The factory provides a final dimension and wiring drawing for customer approval before production starts, and the approved drawing becomes the manufacturing specification. Standard packaging is suitable for sea freight, and KITOZER can arrange air freight for urgent replacement orders on request. Every unit ships with a factory test report, a quick-start guide, and a bag of spare cable glands.
Price
From $1,480 per unit with basic protection, and from $2,680 per unit with full string monitoring. Contact the KITOZER engineering team for a project-specific bill of materials and factory lead time.