KITOZER 1600kVA Oil Immersed Transformer 35kV Industrial Power

Product Overview

The KITOZER 1600kVA oil immersed transformer is a heavy duty liquid filled unit designed to step 35kV transmission voltage down to 10kV or 0.4kV for large industrial plants, mining operations, and municipal substations. The corrugated fin tank conserves oil expansion while eliminating the need for a conservator, reducing maintenance points. KITOZER builds the core with mitered step lap silicon steel and copper windings to deliver low loss, high efficiency, and excellent short circuit withstand. The unit is supplied with a complete protection package including thermometer, pressure relief, and dehydration breather.

Technical Specifications

Rated 1600kVA, 35kV primary, 10.5kV or 0.4kV secondary, 50Hz. Vector group Dyn11. Off circuit tap changer plus or minus 2 by 2.5 percent. Impedance 6.5 percent. Cooling ONAN, optional ONAF with fan banks. Insulation class A. Oil volume approximately 650L. HV bushings 35kV porcelain, LV bushings 1kV. Temperature indicator with contacts for fan start and alarm. Pressure relief valve, silica gel breather, magnetic oil level gauge. Weight approximately 7800kg, dimensions 2600mm by 1500mm by 2400mm. Standards IEC 60076, GB/T 6451, GB 20052, CE.

Application Scenarios

Typical installations include 35kV industrial incoming substations for cement plants, chemical facilities, paper mills, and large water pumping stations. It also serves as a step down transformer for 35kV wind farm collector grids and large solar farms. The oil immersed design suits remote outdoor locations where regular maintenance access is limited.

Advantages and Features

High overload capability during summer peak load. Corrugated fin tank reduces oil aging and eliminates conservator leaks. KITOZER offers an on load tap changer option to regulate voltage within plus or minus 4 percent under load, ideal for weak rural grids. A stainless steel tank is available for coastal salt air. The integrated thermometer and pressure relief provide a complete protection package without extra field wiring. Factory routine and type tests are performed at an accredited laboratory.

Installation and Maintenance

Provide a 10 ton concrete plinth with bund wall and oil retention. Use a crane rated for 8 tons on the lifting lugs. Verify oil level and silica gel color before energizing. Annual tests include oil dielectric, DGA dissolved gas analysis, winding resistance ratio, and earth continuity. Replace silica gel when it turns pink. KITOZER recommends oil reconditioning every six years and a bushings power factor test every three years.