KITOZER
KITOZER

KITOZER 19-inch Rack-mounted UPS Solution for Cabinets

I. System Introduction

The 19-inch rack-mounted UPS (Uninterruptible Power Supply) is a dedicated power protection device designed for standard 19-inch server cabinets. Adopting a rack-mounted installation method with height measured in “U” (1U=44.45mm), it can be installed in the same cabinet as IT infrastructures such as servers and network devices. This design saves computer room space and improves space utilization efficiently. The KITOZER rack-mounted UPS system features a double-conversion online topology, achieving zero-millisecond switching between mains power and battery power supply. It provides continuous, stable and pure power supply for critical loads, effectively protecting IT equipment from damages caused by power anomalies including mains interruption, voltage fluctuation, frequency drift and harmonic interference.

Integrated with advanced DSP digital signal processing technology, intelligent Battery Management System (BMS) and network monitoring functions, the system supports remote management and operation & maintenance. It is widely applied in scenarios requiring ultra-high power quality and reliability, such as data centers, server rooms, communication base stations, financial institutions, medical equipment and industrial automation systems.

19 inch rack mount ups solution (8)

II. System Composition

The KITOZER 19-inch rack-mounted UPS system consists of the following core components:

Component NameFunctional Description
Rectifier / ChargerConverts AC mains power into DC power to supply stable DC power to the inverter and charge the battery pack simultaneously
InverterConverts DC power into pure sine-wave AC output to ensure high-quality power supply for loads
Static SwitchRealizes fast switching between mains power and inverter output with zero-millisecond conversion
Battery PackEnergy storage device that supplies DC power to the inverter to ensure continuous power supply when mains power is abnormal
Battery Management System (BMS)Real-time monitoring of battery status including voltage, current, temperature and internal resistance; prevents overcharging and overdischarging to extend battery service life
DSP Digital ControllerCore control unit that realizes full digital control of the system, optimizes operating efficiency and provides multiple protection functions
Input/Output Power Distribution UnitRealizes distribution and protection of power input and output, equipped with circuit breakers, surge protection modules and other components
Monitoring & Communication ModuleProvides RS232, USB, SNMP and other communication interfaces to support local and remote monitoring
Human-Machine Interaction InterfaceEquipped with LCD display and keys to show system operating parameters and fault information and support parameter configuration
Cooling SystemIntelligent temperature-controlled fan that automatically adjusts speed according to load and temperature to reduce noise and improve operating efficiency
19 inch rack mount ups solution (7)

III. System Classification

3.1 Classification by Power Capacity

Power GradeDimension SpecificationApplicable Scenarios
Low Power1-3kVA, 1U/2U heightSmall computer rooms, network cabinets, edge computing nodes
Medium Power5-10kVA, 2U/3U heightMedium-sized computer rooms, server clusters, storage devices
High Power15-40kVA, 3U/6U heightLarge data centers, high-density server cabinets, critical business systems

3.2 Classification by Topology Structure

Topology TypeWorking PrincipleAdvantagesApplicable Scenarios
Double-conversion OnlineMains power → Rectification → Inversion → Load, with full-process voltage and frequency stabilizationZero switching time, complete isolation of mains interferenceCore businesses, critical equipment, medical systems
Line InteractiveDirect power supply with voltage stabilization under normal mains conditions; switch to inversion power supply when anomalies occurHigh efficiency, moderate costNon-core businesses, general servers
StandbyBypass power supply under normal mains conditions; inverter starts working when anomalies occurLow cost, compact sizePersonal computers, small network devices

The full range of KITOZER rack-mounted UPS adopts double-conversion online topology to ensure the highest level of power protection.

3.3 Classification by Battery Configuration

Configuration TypeFeaturesApplicable Scenarios
Built-in Battery TypeBattery pack is built into the UPS chassis with no extra space requiredSmall computer rooms with limited space, rapid deployment scenarios
External Battery TypeBattery pack is independently installed in cabinets or battery cabinets with flexible expansion capabilityCritical businesses requiring long-delay power supply, large data centers
Modular Expandable TypeHot-swappable battery modules support online capacity expansionScenarios with dynamic load changes and computer rooms requiring flexible expansion
19 inch rack mount ups solution (6)

IV. System Configuration List (KITOZER Brand)

4.1 Standard Configuration List (10kVA Example)

No.Equipment NameModelSpecification ParametersQuantity
119-inch Rack-mounted UPS HostKITOZER-R10K10kVA/9kW, 2U height, double-conversion online type, 220V/380V input, 220V output1 Unit
2Built-in Battery PackKITOZER-BATT-10K8 pieces of 12V/9Ah valve-regulated lead-acid batteries1 Set
3Input Power Distribution ModuleKITOZER-PDU-IN32A circuit breaker, surge protection, input terminal block1 Unit
4Output Power Distribution ModuleKITOZER-PDU-OUT8×16A C13 sockets + 2×32A C19 sockets1 Unit
5Monitoring Communication CardKITOZER-SNMP-01Supports SNMP/HTTP/HTTPS, remote monitoring1 Piece
6Network Management SoftwareKITOZER-NMS-01Supports centralized management of multiple devices, alarm notification and data statistics1 Set
7Rack Mounting KitKITOZER-RMK-02Compatible with 19-inch standard cabinets, including guide rails and screws1 Set
8Operation Manual & CDKITOZER-DOC-01Including user manual, installation guide and software CD1 Set
9Warranty Card & Certificate of ConformityKITOZER-WTY-01Including 3-year warranty certificate and product qualification certificate1 Set

4.2 Optional Configuration List

No.Equipment NameModelSpecification ParametersRemarks
1External Battery CabinetKITOZER-BC-16Capable of holding 16 pieces of 12V batteries, 19-inch 3U heightOptional for long-delay power supply
2Battery Inspection ModuleKITOZER-BIM-08Monitors cell voltage and temperature of 8 batteriesImproves battery management accuracy
3Environment Monitoring ModuleKITOZER-EM-01Monitors temperature, humidity, smoke detection and door access statusRealizes comprehensive computer room environment monitoring
4Remote Maintenance ModuleKITOZER-RMM-01Supports 4G/5G remote access and fault diagnosisSuitable for unattended computer rooms
5Parallel ModuleKITOZER-PAR-01Supports parallel operation of multiple UPS units to improve reliabilitySuitable for large data centers
6Isolation TransformerKITOZER-IT-10K10kVA, isolated output, common-mode interference suppressionFor medical equipment and precision instruments
19 inch rack mount ups solution (5)

V. System Schematic Diagram

Mains Input → Input Power Distribution Unit (Surge Protection/Circuit Breaker) → Rectifier → DC Bus → Inverter → Output Power Distribution Unit → Load

        │                                 │

        │                                 │

        └──────────── Static Switch ────────────┘

                       │

                 Battery Pack (BMS Management)

                       │

               Monitoring Communication Module (RS232/USB/SNMP)

                     │

               Human-Machine Interaction Interface (LCD/Keys)

Working Process Description

1. Normal Mains Power: Mains power enters the rectifier through the input power distribution unit and is converted into DC power. Part of the DC power supplies the inverter, and the other part charges the battery pack. The inverter converts DC power into pure sine-wave AC power, which is supplied to the load through the output power distribution unit; the static switch stays on the inverter side.

2. Abnormal Mains Power: The rectifier stops working, and the battery pack supplies DC power to the inverter via the DC bus to ensure continuous load operation. The static switch remains on the inverter side to realize zero-millisecond switching.

3. Mains Power Recovery: The rectifier restarts, charges the battery pack first, and switches back to the normal working mode after the voltage stabilizes.

4. Fault Protection: When the inverter fails, the static switch quickly switches to the mains bypass to ensure uninterrupted power supply for the load and trigger an alarm signal simultaneously.

19 inch rack mount ups solution (4)

VI. Product Technical Parameters

Technical Parameter Table of KITOZER-R Series 19-inch Rack-mounted UPS (10kVA Example)

ItemParameter Specification
Basic Parameters 
ModelKITOZER-R10K
TypeDouble-conversion Online Rack-mounted UPS
Rated Capacity10kVA/9kW (Power Factor: 0.9)
Dimension19-inch standard rack, 2U height (88.9mm), depth 650mm
Weight35kg (with built-in battery)
Input Parameters 
Input Voltage220V/380V (optional), single-phase/three-phase (optional)
Input Voltage Range120V~275V (wide input range)
Input Frequency50/60Hz, automatic identification
Input Frequency Range40Hz~70Hz
Input Power Factor≥0.99 (full load)
Input Harmonic Distortion≤3% (full load)
Output Parameters 
Output Voltage220V/380V (optional), single-phase/three-phase (optional)
Output Voltage Accuracy±1% (steady state), ±3% (dynamic state)
Output Frequency50/60Hz, synchronized with input (mains mode), ±0.1Hz (battery mode)
Output WaveformPure sine wave, THD≤3% (linear load), ≤5% (non-linear load)
Switching Time0ms (mains/battery)
Overload Capacity125% load for 10 minutes; 150% load for 1 minute; 1000% load for 200ms
Battery Parameters 
Battery TypeValve-Regulated Lead-Acid Battery (VRLA)
Battery Voltage96V (8 built-in 12V batteries)
Charging ModeIntelligent three-stage charging with temperature compensation
Battery ManagementBuilt-in BMS for monitoring voltage, current, temperature and internal resistance
Efficiency & Protection 
Conversion Efficiency≥95% at full load, ≥94% at half load, ≥98% in ECO mode
Protection FunctionsInput over/under voltage protection, output over/under voltage protection, overcurrent protection, short circuit protection, over temperature protection, battery overcharge/overdischarge protection
Communication & Monitoring 
Communication InterfacesRS232, USB, SNMP, dry contact alarm
Monitoring SoftwareKITOZER-NMS network management system, supports Web and APP remote monitoring
Environmental Parameters 
Operating Temperature0℃~40℃
Storage Temperature-25℃~55℃
Relative Humidity0%~95% (non-condensing)
Altitude≤1000m (derating required if exceeded)
Noise Level≤55dB (1-meter distance)
19 inch rack mount ups solution (3)

VII. Product Application Scope

The KITOZER 19-inch rack-mounted UPS system is applicable to the following scenarios:

7.1 Data Centers & Server Rooms

  • Enterprise-level data centers, hosting computer rooms, cloud computing centers
  • High-density server cabinets, blade servers, storage arrays
  • Edge computing nodes, micro data centers

7.2 Communication & Network Systems

  • Communication base stations, core network rooms, transmission equipment
  • Core network equipment, routers, switches, firewalls
  • Data communication equipment, optical transmission equipment, satellite communication systems

7.3 Financial & Commercial Systems

  • Bank data centers, ATM machines, POS systems
  • Securities trading systems, insurance business systems
  • Commercial POS networks, payment settlement systems

7.4 Medical & Scientific Research Institutions

  • Operating room equipment, ICU life support systems
  • Medical imaging equipment (CT, MRI, ultrasound)
  • Laboratory precision instruments and analytical equipment

7.5 Industry & Automation

  • Industrial control systems (PLC, DCS)
  • Production line automation equipment, robot systems
  • Precision processing equipment, semiconductor manufacturing equipment

7.6 Government & Public Services

  • Government cloud platforms, e-government systems
  • Emergency command centers, public security systems
  • Traffic scheduling systems, air traffic control equipment

7.7 Education & Scientific Research

  • Campus network centers, library servers
  • Scientific research computing clusters, supercomputers
  • Distance education platforms, multimedia teaching systems
19 inch rack mount ups solution (2)

VIII. Product Advantages

8.1 Space Optimization Design

  • Standard 19-inch rack mounting with 1U/2U/3U height, coexisting with IT equipment in a single cabinet to save computer room space
  • High-density power design (10kVA in only 2U space) improves cabinet utilization
  • Front and rear ventilation design adapts to the cold and hot aisle layout of cabinets to enhance heat dissipation efficiency

8.2 Excellent Power Protection

  • Double-conversion online topology with zero-millisecond switching completely isolates mains power interference
  • Pure sine-wave output with THD≤3% meets the power supply requirements of precision equipment
  • Wide input voltage range (120V~275V) adapts to harsh power grid environments
  • Comprehensive protection functions including overvoltage, undervoltage, overcurrent, short circuit, over temperature and battery protection

8.3 High-efficiency Energy Saving

  • Full-load efficiency ≥95% and ECO mode efficiency ≥98% reduce operating costs
  • Intelligent fan control automatically adjusts speed based on load and temperature to lower noise and energy consumption
  • Power Factor Correction (PFC) technology achieves input PF≥0.99 and reduces power grid harmonic pollution
  • Complies with national first-class energy efficiency standards to support green data center construction

8.4 Intelligent Management Functions

  • DSP full digital control features fast response speed and high control accuracy
  • Advanced BMS extends battery service life by more than 30%
  • Multiple communication interfaces (RS232, USB, SNMP) support remote monitoring and management
  • Compatible with mainstream network management platforms to support centralized monitoring and alarm notification
  • Chinese and English LCD display enables convenient operation and real-time system status monitoring

8.5 High Reliability Design

  • Redundant configuration of key components (fans, capacitors) improves system availability
  • Supports N+1 parallel redundancy and multi-unit parallel operation to enhance system reliability
  • Hot-swappable battery modules support online replacement and reduce maintenance difficulty
  • Industrial-grade components with MTBF≥200,000 hours ensure long-term stable operation

8.6 Flexible Expansion Capability

  • Modular design supports online expansion of power and battery modules
  • Compatible with external battery cabinets for flexible backup time configuration
  • Supports multiple output socket configurations to adapt to different equipment power interfaces
  • Expandable environment monitoring module realizes full monitoring of computer room temperature, humidity and smoke

IX. Bid-winning Control Parameters

9.1 Core Bid-winning Control Parameters (* Mandatory Items)

No.Parameter NameControl Requirements
1*Product Type19-inch rack-mounted UPS, double-conversion online topology, zero-millisecond switching
2*Rated CapacityNo less than 10kVA/9kW, power factor 0.9
3*Dimension SpecificationStandard 19-inch rack mounting, height ≤2U (88.9mm)
4*Conversion EfficiencyFull-load efficiency ≥95%, half-load efficiency ≥94%, ECO mode efficiency ≥98%
5*Input ParametersVoltage range 120V-275V, frequency range 40Hz-70Hz, input PF≥0.99
6*Output ParametersPure sine-wave output, THD≤3% (linear load), voltage accuracy ±1%
7*Battery ManagementBuilt-in intelligent BMS for monitoring single battery voltage, temperature and internal resistance, supporting battery charge and discharge management
8*Communication FunctionSupports RS232, USB and SNMP communication, equipped with network management software
9*Protection FunctionsEquipped with input over/under voltage, output over/under voltage, overcurrent, short circuit, over temperature and battery protection functions
10*Reliability IndexMTBF≥200,000 hours, supports N+1 parallel redundancy
11Operating Temperature0℃~40℃, adaptable to various environmental conditions
12Noise Level≤55dB (1-meter distance), meeting computer room environmental requirements
13Certification RequirementsEquipped with CE, UL and ISO9001 certifications, compliant with relevant national standards
14Warranty PeriodWhole machine warranty ≥3 years, battery warranty ≥2 years
15Brand RequirementsThe bidding product must be KITOZER brand with original manufacturer authorization certificate provided

9.2 Technical Deviation Table (Example)

No.Control ParameterBidding Product ParameterDeviation StatusRemarks
1Full-load efficiency ≥95%95.5%Positive DeviationHigher efficiency than standard requirements
2Output THD≤3%2.8%Positive DeviationLower harmonic distortion than standard requirements
3MTBF≥200,000 hours250,000 hoursPositive DeviationHigher reliability than standard requirements

X. Product Solution Cases

10.1 Single Cabinet Protection Solution for Small Computer Rooms (1-3kVA)

Applicable Scenarios

  • Small enterprise computer rooms, network cabinets, edge computing nodes
  • Load power ≤3kVA requiring independent single-cabinet protection
  • Limited space and moderate budget

Solution Configuration

  • 1 set of KITOZER-R3K (3kVA/2.7kW, 1U height) built-in battery UPS host
  • Standard 19-inch cabinet with guide rail mounting kit
  • Basic monitoring module (RS232+USB)
  • Input and output power distribution unit (4×C13 sockets)

Solution Features

  • Integrated design with convenient plug-and-play installation
  • Built-in battery requires no extra installation space
  • Supports rapid deployment and meets basic power protection requirements

10.2 Multi-cabinet Parallel Solution for Medium-sized Computer Rooms (5-10kVA)

Applicable Scenarios

  • Medium-sized enterprise data centers and server clusters
  • Load power 5-10kVA requiring high-reliability guarantee
  • Critical business systems with zero power outage tolerance

Solution Configuration

  • 2 sets of KITOZER-R10K (10kVA/9kW, 2U height) UPS hosts with N+1 parallel redundancy
  • KITOZER-BC-16 external battery cabinet for 1-hour backup power supply
  • Centralized monitoring system supporting Web remote management
  • Input and output power distribution system with ATS automatic transfer switch
  • Environment monitoring module (temperature, humidity, smoke, door access)

Solution Features

  • Parallel redundant design achieves system availability up to 99.999%
  • Long-delay power supply ensures continuous operation of critical businesses
  • Centralized monitoring facilitates unified management and maintenance

10.3 Modular Solution for Large Data Centers (15-40kVA)

Applicable Scenarios

  • Large enterprise data centers and cloud computing centers
  • High-density server cabinets with 15-40kVA load power
  • Scenarios requiring phased capacity expansion and flexible configuration

Solution Configuration

  • KITOZER-R series modular UPS (3U height, 10kVA per module)
  • 4 power modules (3+1 redundancy) with total capacity of 30kVA
  • External battery array for 2-hour backup power supply
  • Intelligent battery management system supporting hot-swappable replacement
  • Centralized monitoring platform supporting SNMP and Modbus protocols
  • Input and output power distribution cabinet with precision power distribution monitoring

Solution Features

  • Modular design supports online capacity expansion to maximize return on investment
  • Hot-swap technology reduces maintenance difficulty and improves system availability
  • Intelligent monitoring enables real-time system status tracking and early warning
  • High efficiency and energy saving reduce data center PUE value

XI. Product Application Cases

11.1 Data Center Renovation Project of a Financial Institution

Project Background

As a large domestic bank, the customer’s existing data center UPS system was aging with single-point failure risks. A system upgrade was required to ensure 7×24-hour uninterrupted operation of core business systems.

Solution

  • Adopted 4 sets of KITOZER-R20K (20kVA/18kW, 3U height) UPS hosts with 2+2 parallel redundancy
  • Configured external battery packs for 2-hour backup power supply
  • Deployed centralized monitoring system connected to the bank’s existing IT management platform
  • Adopted cold and
Shopping Cart