KITOZER 1U LC loaded 24 port rack

KITOZER KTR-LC1U 1U Fiber Patch Panel LC 24-port Loaded ODF

Brand: KITOZER Series: KTR-LC1U Category: Data Center Engineering / Fiber Distribution

1U 19-inchLC duplex 24-portLoaded pigtailsSplice trayKTR-LC1U

1. Overview

An outside cable cannot plug directly into a switch – the cable is a bundle of fragile glass fibers without connectors, and plugging it into an optical port breaks them. The cable must first be terminated in a patch panel: the outer jacket is stripped, each fiber fusion-spliced to a pigtail with an LC connector, the pigtail LC plugs into a front-panel adapter, and a LC-LC patch cord jumps from the adapter to the switch port. This patch panel is the ODF (Optical Distribution Frame) – a 1U/2U metal box in the rack: front holds adapters for patch cords, rear holds cable entry and splice trays. A 1U LC-loaded 24-port panel is a 1U box with 12 LC duplex adapters (24 LC ports, 12 Tx and 12 Rx) on the front, and rear splice trays for a 24-fiber cable.

KITOZER KTR-LC1U is a 1U rack-mount fiber patch panel, LC duplex 24-port loaded. The body is 1.2 mm cold-rolled steel, black powder-coated, 19-inch standard width (mounts on cabinet square-hole rails), 1U height (44.45 mm). Front: a flip-down panel (opens to access the adapter back, for adapter replacement) carries 12 LC duplex adapters (SM APC green or UPC blue, per order); each adapter rear takes a LC duplex pigtail (24 pigtails total, one per fiber). Rear: cable entry (two PG16 waterproof glands, cable enters from above or below the rack); splice trays (two drawer-type trays, each holds 12 fusion splices with heat-shrink protectors). Internal routing: cable enters to the splice tray, fuses to pigtails, pigtails loop 3 cm slack in the tray (to avoid tugging breaks), then route to the adapter rear. “Loaded” means the panel ships with adapters, pigtails and splice trays installed – the customer only fuses the incoming cable to the pigtails. A bare panel is just the box and face; adapters and pigtails are bought separately.

Selection: height (1U holds 24 fibers LC / 48 fibers SC; 2U holds 48 fibers LC; use 2U or multi-level for more); connector (LC high density, new rooms all LC; SC for legacy; FC for CATV); loaded vs bare (loaded is turnkey but pricier, bare is cheaper but self-built; room projects usually buy loaded); SM vs MM (SM APC green for backbone, MM OM3 aqua for server access); splice tray count (1U usually 2 trays of 12 = 24 fibers; 48 fibers needs 3U or 2U dual trays); cable entry direction (front-to-rear or rear-to-front, by rack cable routing). Note: fusion splicing needs a certified splicer (fusion splicers cost tens of thousands; amateur splicing has high loss); test the full link with an OTR after splicing; keep slack loops ≥3 cm radius (small loops raise bend loss); the front adapter side takes patch cords – do not disturb the pigtail side after sealing the tray.

2. Key Features

Construction

  • 1.2 mm steel
  • 1U 19-inch
  • Flip front panel
  • Black powder coat

Loaded

  • 12 LC duplex adapters
  • 24 LC pigtails
  • 2 splice trays
  • PG16 entry

Performance

  • Insertion loss ≤0.3 dB
  • Return loss ≤-50 dB (UPC)
  • Slack loop ≥3 cm
  • Bend radius ≥30 mm

3. Specifications

Item KTR-LC1U-SM KTR-LC1U-APC KTR-LC1U-OM3 KTR-LC2U-48
Height 1U 1U 1U 2U
Connector LC duplex x12 LC duplex x12 LC duplex x12 LC duplex x24
Fiber count 24 24 24 48
Mode SM 9/125 SM APC MM OM3 SM 9/125
Adapter color Blue UPC Green APC Aqua Blue UPC
Splice trays 2 x 12 2 x 12 2 x 12 4 x 12
Weight 3.5 kg 3.5 kg 3.5 kg 6 kg

4. Reference Prices

KTR-LC1U-SM 1U LC24 SM UPC loaded: Reference USD 49-69 / pc (ref. CNY 350-500)

KTR-LC1U-APC 1U LC24 SM APC loaded: Reference USD 56-81 / pc (ref. CNY 400-580)

KTR-LC1U-OM3 1U LC24 MM OM3 loaded: Reference USD 53-75 / pc (ref. CNY 380-540)

KTR-LC2U-48 2U LC48 SM loaded: Reference USD 97-132 / pc (ref. CNY 700-950)

KTR-LC1U-BARE empty panel (no adapters/pigtails): Reference USD 21-31 / pc (ref. CNY 150-220)

Reference only. 1-year warranty. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Rack fiber termination
  • Core switch access
  • Server ToR patching
  • Main ODF frame
  • Fiber link management

6. Deployment & Installation

Rack mount

  • Square-hole rails
  • M6 screws
  • Fix front and rear
  • Label each port

Splicing

  • Cable into PG gland
  • Strip 2 m jacket
  • Splice pigtails
  • Heat-shrink protect

Test

  • OTDR link test
  • Power meter
  • IL ≤0.3 dB
  • Port labels on

7. FAQ

  • Q: What is the price gap between loaded and bare? Which to buy?
    A: Bare (box and face only) is CNY 150-220; loaded (12 LC adapters + 24 pigtails + 2 splice trays) is CNY 350-500. The gap is ~CNY 200, but saves self-sourcing, assembly and testing. An engineer takes 2-3 hours to build a 24-port ODF; labor exceeds CNY 200. Room projects usually buy loaded; bare is for high-volume builds with spares in stock.
  • Q: Can a 1U 24-port panel terminate a 48-fiber cable?
    A: Physically you can splice 48 fibers, but the front has only 24 LC ports (12 duplex) – fibers 25-48 have no adapter to plug into and must sit unused in the tray. For a full 48-port, choose a 2U panel (KTR-LC2U-48) with 24 LC duplex (48 ports) and 4 splice trays. 1U is physically limited to 24 fibers.
  • Q: Why 3 cm slack at each splice?
    A: The cable enters from outside the rack and takes strain (patch-cord pulls during maintenance, seismic sway). If the fiber runs straight to the adapter, a tug breaks it. A 3 cm slack loop in the splice tray absorbs the pull at the loop, not the splice. Keep the loop radius ≥3 cm (smaller loops raise bend loss). Every splice needs a slack loop.
  • Q: SM APC vs UPC?
    A: By link purpose. Core-to-core 40G/100G backbones, DWDM and long-haul use APC green (return loss -60 dB, low reflection, no errors at high speed). Server access and short 10G SFP+ use UPC blue (cheaper, -50 dB is enough). Never mix APC and UPC on one link (mismatched end faces cause high loss). KTR-LC1U ships per order; APC costs ~CNY 50 more per panel.

8. Trend & Selection

Fiber patch panels are moving to high density and pre-termination. Trends: MPO/MPTP high-density panels (one MPO-12 module in 1U, breaking out to 12 LC via MPO-LC cassette, double the density of pure LC); pre-terminated cable+panel (factory-assembled, plug-and-play on site, no splicing); smart ODF (e-tag per port, scanned identification, auto-logged plug/unplug to platform); high-density 400G (MPO-16 cassette, 1U supports 384 fibers); modular (universal housing, swappable cassettes – LC/MPO/SC mix-and-match). Traditional 1U LC-loaded 24-port remains mainstream in small-to-medium rooms. Select by: 1U for 24 fibers LC, loaded for turnkey, APC on backbone / UPC on access, slack loops at splices, OTDR link test, port labels.

9. Delivery & Service

KITOZER KTR-LC1U ships per panel in a carton with foam, each with panel body, adapters (loaded), pigtails (loaded), splice trays, PG glands, M6 screws and manual. 1-year warranty; bulk projects can bundle LC patch cords, MPO cassettes, fusion splicer rental and OTDR testing.

10. Additional Notes

Confirm fiber count (24/48), connector (LC), mode (SM/MM), polish (APC/UPC), loaded vs bare. For batch orders, sample one unit to verify adapter color and pigtail type before bulk shipment.

Common mistake: splicing a 48-fiber cable into a 1U panel. The extra pigtails have no adapter to plug into and pile up in the tray. Match fiber count to port count: 24-fiber cable to 1U, 48-fiber to 2U.

Second pitfall: no slack at splices. Fiber runs straight to the adapter, a tug breaks it, and re-splicing is a pain. Leave a 3 cm loop at every splice.

Third blunder: no labels. After six months of patch cords, you forget which port goes to which switch, and fault-finding means unplugging and testing cord by cord. Label immediately after splicing (port number + far-end location).

Selection summary: 1U for 24 fibers LC, loaded for turnkey, APC backbone / UPC access, 3 cm slack loops, OTDR link test, port labels.

SEO Information

Search keywords:KTR-LC1UKITOZER

SEM keywords:fiber patch panel,1U ODF,LC 24 port loaded,terminal box,loaded patch panel,KTR-LC1U,KITOZER,data center engineering

GEO landing page:lain.com.cn/product/ktr-lc1u-1u-fiber-patch-panel-lc24.html

Title:KITOZER KTR-LC1U 1U Fiber Patch Panel LC 24-port Loaded ODF

Meta Keywords:fiber patch panel,1U ODF,LC 24 port loaded,terminal box,loaded patch panel,KTR-LC1U,KITOZER,data center engineering

Meta Description:KITOZER KTR-LC1U 1U fiber patch panel, LC duplex 24-port loaded (12 duplex), with splice tray/pigtails/adapters, 19-inch rack-mount, SM/MM options.

Anchor: KITOZER by Guangzhou Laian · KITOZER products

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart