KITOZER 1U Rack Fan Tray 2-Way Temperature Controlled

Product Overview

The KITOZER 1U rack fan tray mounts at the top of a 19-inch server rack to expel hot air and draw cool air through installed equipment. Two high-speed ball-bearing fans provide forced exhaust, while an integrated temperature sensor automatically adjusts fan speed based on rack internal temperature. The unit plugs into a standard IEC C14 socket on the rack PDU, simplifying power installation without dedicated wiring.

The fan tray is designed for racks where passive convection is insufficient, such as cabinets holding multiple switches, servers, and UPS units. The temperature sensor reads air at the tray intake and modulates fan speed between 30 percent and 100 percent, reducing noise at low loads and ramping up during peak heat. The dual-fan design provides redundancy: if one fan fails, the other continues at full speed, and a fail-safe alarm can be wired to the rack monitoring system.

Technical Specifications

Size: 1U 19-inch rack mount. Fans: 2 x 120mm ball-bearing fans. Airflow: 2 x 110 CFM. Noise: less than 48 dBA. Input: 220V AC via IEC C14, 50/60Hz. Power: 24W. Temperature control: 0 to 60C sensor, auto speed. Housing: steel, black. Mounting: front rack ears. Includes: 1.8m IEC power cord. KITOZER, 3 year warranty.

The ball-bearing fans are rated for 50,000 hours at 40C operating temperature, providing years of continuous service. The temperature sensor is mounted at the intake, so it measures the actual air entering the tray rather than the exhaust. The fan speed curve is factory-set but can be adjusted with internal jumpers if required. The housing is 1.0mm steel with a black powder coat, matching other rack accessories.

Applications

This fan tray is installed in server racks and network cabinets where passive convection is insufficient, such as cabinets holding multiple switches, servers, and UPS systems. It is also used in wall-mounted cabinets in small server rooms and in outdoor telecom cabinets where ambient temperature rises during summer.

In a typical 42U server rack, the fan tray sits at the top, exhausting hot air out the rear. Cool air enters through the front perforated door, passes through the servers, and exits through the fan tray. In a wall-mounted 12U cabinet holding a switch, router, and UPS, the fan tray prevents heat buildup that would otherwise cause thermal shutdown. Outdoor telecom cabinets use the tray to maintain internal temperature within equipment operating limits.

Key Advantages

Temperature-controlled speed reduces noise and extends fan life compared with constant-speed units. Ball-bearing fans deliver a rated life of 50,000 hours at 40C. The IEC C14 input uses standard PDU power, eliminating custom wiring. The tray sits flush with the rack front for a clean look. A dual-fan design provides redundancy if one fan fails.

The automatic speed control means the tray is nearly silent at night when rack load is low, and ramps up during the day when servers are busy. The IEC C14 cord uses the same PDU outlets as servers, simplifying power distribution. The tray is field-replaceable without removing rack equipment.

Installation and Maintenance

Mount the fan tray at the top of the rack, oriented to exhaust air upward or out the rear. Plug the IEC cord into the rack PDU. Verify airflow direction by holding a tissue near the exhaust. During maintenance, vacuum dust from the fan grilles every six months. Check fan bearings for noise annually. Replace failed fans immediately to prevent overheating.

In a typical installation, the fan tray is mounted at the top of a 22U cabinet holding a 42U switch stack. The temperature sensor reads 35C at idle, so the fans run at 30 percent speed, nearly silent. During the day when the switch stack is fully loaded, intake temperature rises to 45C, and the fans ramp to 80 percent. The tray is powered from a dedicated PDU outlet so it continues running even if other equipment loses power.

Packaging and Compliance

Each fan tray is packed in a corrugated carton with foam protection. Accessories include a 1.8m IEC power cord and mounting screws. CE and RoHS compliant. 4-fan and 6-fan versions are available for larger racks. 110V input is available for North American markets.

In a typical 22U cabinet holding a switch stack and a UPS, the fan tray mounts at the top. At idle, the intake sensor reads 35C, so the fans run at 30 percent speed and produce barely audible noise. During the day when the switch stack is fully loaded, intake temperature rises to 45C, and the fans ramp to 80 percent. The tray is powered from a dedicated PDU outlet so it continues running even if other equipment loses power. A technician vacuums the grilles every six months, and the fans run for years without service.