KITOZER 1U Rack Mount Fan Tray 4 Fans For Server Cabinet

Product Overview

The KITOZER 1U rack mount fan tray holds four 120 mm high-speed fans in a 1U chassis, designed to fit any standard 19-inch server or network cabinet. It pulls cool air from the front of the rack and exhausts hot air out of the top, helping to eliminate hot spots when equipment density exceeds natural convection. The fan tray mounts on the top U position or directly above the heat-generating equipment, and includes a temperature sensor with adjustable thermostat so the fans speed up only when needed. A simple 230 V AC power input connects to a local PDU or UPS.

Technical Specifications

Dimensions 1U, 19-inch EIA, 483 x 44 x 250 mm (W x H x D). Fans: 4 x 120 mm ball bearing, 220 V AC, 4000 RPM. Airflow 4 x 120 m3/h = 480 m3/h total. Noise 55 dB(A). Power input 230 V AC 50 Hz, 60 W. Thermostat range 25 to 45 degrees Celsius, adjustable. Included: IEC C14 inlet, 1.8 m power cord, two spare fan fuses. Mounting: front rack ears with M6 cage nuts. CE, RoHS. Warranty 2 years.

Application Scenarios

This fan tray is used in server cabinets that house dense switches, storage arrays, or GPU compute nodes in rooms without raised-floor cooling. It is also deployed in wall-mount network cabinets, test labs, and equipment closets where ambient temperature is marginal. The thermostat control means the tray runs quietly at low load and ramps up when servers are busy. It is a common retrofit for existing racks that run hot in summer.

Key Advantages

The 480 m3/h airflow matches the exhaust of a dense 20U rack. The thermostat saves energy and reduces noise at low load. The standard 1U size fits any 19-inch cabinet. The ball bearing fans are rated for 50,000 hours at 40 degrees. The front-facing power inlet makes cord routing simple. The tray can be moved between cabinets during reconfiguration.

Installation and Maintenance Recommendations

Mount the fan tray in the top U of the cabinet, blowing air upward and out of the top vent. Do not block the top vent with cable bundles. Set the thermostat to turn fans on at 30 degrees Celsius. Keep the cabinet front and rear doors closed so airflow follows the intended path. Clean fan filters every three months in dusty environments. Replace a fan immediately if it becomes noisy or stops spinning, to avoid unbalanced cooling. Check the power cord and IEC inlet annually for heat marks.