KITOZER
KITOZER

KITOZER 2-zone Gas Extinguishing Control Panel

The KITOZER 2-zone gas extinguishing control panel is the intelligence hub for a clean agent, inert gas, or CO2 fire suppression system. It supervises two independent detection zones, runs the cross-zone confirmation logic, triggers pre-discharge alarms, counts down the abort timer, and energizes the release solenoid. The panel integrates directly with building fire alarm systems and provides relay outputs for remote monitoring, making it suitable for small to medium server rooms, electrical switchgear rooms, and individual industrial hazards.

Product Overview

The panel is housed in a steel enclosure with a front door, mounted on a wall. The front fascia includes a backlit LCD, status LEDs for each zone, alarm, fault, discharge, and abort conditions, plus push buttons for silence, reset, and lamp test. Inside, the main PCB supervises two Class B detection loops, two programmable relay outputs, a 24-volt DC battery charger, and the release circuit. A built-in sounder drives the local warning horn, and an abort input allows personnel to cancel release during the countdown.

Technical Specifications

Two supervised detection zones, Class B. Detection devices include smoke detectors, heat detectors, and manual call points. Release circuit is supervised at 24 volts DC, 1.5 amperes max. Pre-discharge alarm duration is programmable from 0 to 60 seconds. Abort timer is programmable. Power input is 100 to 240 volts AC, 50 or 60 hertz. Battery backup is 24 volts DC sealed lead-acid for 24 hours standby plus 5 minutes alarm. Relay outputs are two Form C contacts at 2 amps. Operating temperature is 0 to 40 degrees Celsius. Enclosure is IP30 steel.

Application Scenarios

The 2-zone panel protects single rooms such as data center server halls, UPS and battery rooms, electrical switchgear rooms, telecom shelters, and small industrial enclosures. It is also used as a local release panel paired with a larger building fire alarm system. The panel supports both cross-zone logic for two independent detectors and single-zone logic for thermal or manual release, giving designers flexibility for different hazard types.

Advantages

The panel combines detection supervision, alarm, and release logic in one compact unit, reducing wiring and installation cost. Cross-zone confirmation minimizes false release risk. The abort timer gives personnel time to evacuate or cancel if the alarm is spurious. Relay outputs integrate with building management and CCTV systems. Battery backup ensures operation during power failure. The LCD and LEDs provide clear local diagnostics without a laptop.

Installation and Maintenance

Mount the panel on a solid wall near the entrance to the protected space, at viewing height. Route detection loops in conduit, and keep release wiring separated from signal wiring. Connect the abort station and warning horn outside the protected room. After wiring, power up and run the device walk test, verifying each detector and call point. Test release logic with a dummy load instead of the solenoid. Inspect batteries annually and replace every 3 to 5 years. Test the panel quarterly: alarm, silence, abort, and reset functions. Keep the firmware updated via the service port when available.

Engineering Notes

Plan the panel location near the protected room entrance so operators can see status during evacuation. Provide a 24V battery sized for 24 hours standby plus 5 minutes alarm. Route detection loops in separate conduit from release wiring to avoid induced faults. Order spare fuses, relay cards, and a backup battery at project start. Label each zone on the fascia and inside the door with a point list.

Code and Compliance

The panel must be installed under local fire alarm and gas release standards. Submit the detection loop schedule and release logic for authority approval. Annual inspection includes a full functional test of detection, alarm, abort, and release circuits. Battery replacement is required every 3 to 5 years. Keep a service log on site.

Warranty and Accessories

From $780 per 2-zone panel, excluding battery and detectors. The panel carries a two-year warranty. KITOZER supports loop design, detector selection, and commissioning. Spare batteries, relay modules, and display boards are held in stock. Contact +86 13922289957 for multi-zone panel pricing.

Detailed Application Examples

A 2-zone panel protects a 60 cubic meter server room: zone 1 is smoke detection on the ceiling, zone 2 is heat detection under the floor. Cross-zone confirmation prevents false release. The pre-discharge alarm runs 30 seconds, the abort button is at the door, and the panel relays report to the building management system. Batteries are replaced every 4 years.

System Integration

The panel integrates with the building fire alarm system through a pair of Form C relays, one for general alarm and one for fault. These contacts feed the main fire panel so that a gas release event is visible to the whole building. Optional Modbus allows the panel to report zone status, alarm events, and battery voltage to the DCIM platform. This remote visibility reduces the need for on-site checks and gives operators early warning of faults. The panel also provides a dedicated release contact that starts ventilation shutdown and damper closure before agent discharge.

Price

From $780 per 2-zone panel, excluding battery and detectors. Contact +86 13922289957 for multi-zone panel pricing.