KITOZER
KITOZER

KITOZER 200kVAR Capacitor Compensation Cabinet For Power Factor

Product Overview

The KITOZER 200kVAR capacitor compensation cabinet is a low voltage automatic power factor correction panel designed to raise power factor to 0.95 or above, reducing demand penalties and releasing transformer capacity. The cabinet houses a reactive power controller, switched capacitor steps, detuned reactors, and contactor or thyristor switching. KITOZER builds the panel for industrial plants, commercial buildings, and infrastructure sites where induction motors and welders cause low power factor. Automatic step switching responds in under one second to varying load conditions.

Technical Specifications

Rated 400V three phase, 50Hz, total compensation 200kVAR in steps of 25 or 50kVAR. Power factor controller with 12 step output, measuring voltage, current, and power factor. Capacitors: self healing type, 400V, with overpressure disconnector. Detuned reactor 7 percent or 14 percent to suppress harmonics. Switching: contactor for 25kVAR steps or thyristor for fast response. Main breaker 400A MCCB. Incoming current 300A. Protection: surge arrester, fuse per step. Panel IP30, floor standing. Standards IEC 60831, IEC 61439, GB 7251, CE.

Application Scenarios

This cabinet is used in factories with many induction motors, air compressors, pumps, and HVAC systems. It also serves commercial buildings with elevators, chillers, and LED lighting. The detuned version is recommended for sites with VFDs, UPS, or switching power supplies that generate harmonics.

Advantages and Features

Automatic controller maintains target power factor around the clock. Self healing capacitors safely clear internal faults. Detuned reactors prevent harmonic resonance and extend capacitor life. KITOZER offers options including thyristor switching for fast fluctuating loads, a power quality meter with harmonic display, and Modbus communication to the BMS. The compact cabinet fits in standard electrical rooms.

Installation and Maintenance

Mount on a flat floor with 800mm clearance for cable entry and door opening. Connect incoming and outgoing cables per one line diagram. Ensure the controller current transformer is installed on the main incoming line. Commissioning: set target PF to 0.98, configure step sizes, and observe step switching on real load. Annual maintenance includes capacitor capacitance measurement, contactor contact check, and filter reactor resistance. KITOZER recommends replacing capacitors every 8 to 10 years.

Price

From $2,680/pc. Contact +86 13922289957 for capacitor bank pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart