Table of Contents
ToggleProduct Overview
The KITOZER 20ft container data center with 20kW IT load capacity is a fully integrated, factory prefabricated edge computing enclosure built inside a standard ISO 20ft shipping container. It combines power distribution, precision air conditioning, UPS backup, fire suppression, environmental monitoring, and physical security into one plug-and-play unit. The solution is engineered for outdoor deployment in remote sites, rural telecom hubs, manufacturing plants, oil and gas fields, mining camps, and temporary event infrastructure where a traditional building server room is not practical. The container shell is constructed from corten steel with polyurethane insulation, rated IP55 for outdoor weather protection, and coated with anti-corrosion paint suitable for coastal and industrial environments.
Technical Specifications
The IT load capacity is 20kW continuous, supporting up to 12 standard 42U server racks arranged in a single row with hot aisle containment. Power distribution includes a 63A three-phase mains inlet, automatic transfer switch, and 20kVA online double-conversion UPS with 15 minutes of battery backup. Cooling is delivered by two 12kW wall-mounted precision air conditioners with N+1 redundancy, maintaining a setpoint of 24 degrees Celsius and 50 percent relative humidity. The monitoring system includes temperature, humidity, smoke, water leakage, and door contact sensors, communicating via Modbus TCP and SNMP to a central DCIM platform. Fire suppression uses a pre-engineered gas suppression system with VESDA aspirating detection. Environmental rating is IP55, operating temperature range minus 20 to 55 degrees Celsius, and power supply 380V three-phase 50Hz.
Application Scenarios
This 20ft container data center is ideal for edge computing nodes supporting 5G base station aggregation, smart city surveillance, industrial internet of things gateways, and retail point-of-sale backhaul. It is also widely used as a temporary data center for construction sites, film production units, disaster recovery shelters, and large-scale events that require on-site computing without permanent infrastructure. In remote mining or oil operations, the container can be placed within 50 meters of field equipment, reducing signal cable runs and improving data acquisition latency. Educational institutions and government training centers also deploy these units as portable computer labs or disaster recovery rehearsal sites.
Advantages and Features
The main advantage of the KITOZER 20ft container data center is rapid deployment: the entire unit is tested at the factory before shipment, and on-site commissioning typically takes less than three days after a level concrete pad is prepared. The N+1 redundancy design ensures that a single UPS module or air conditioner failure does not interrupt IT operations. The hot aisle containment design raises cold aisle temperature and improves energy efficiency, with a target PUE below 1.45 in moderate climates. All critical components are sourced from established brands and controlled by a KITOZER master controller that provides local touchscreen visualization plus remote web access. The container is also designed for easy relocation: standard corner castings allow lifting by forklift, crane, or container truck, and all internal cabling uses quick-disconnect connectors.
Installation and Maintenance Recommendations
Site preparation requires a level concrete or gravel pad with drainage slope away from the container. A three-phase power feed and a fiber or copper network drop must be terminated at the external inlet box. During installation, verify that the container is level within 5mm across the length and that all grounding bonds are connected before energizing. Routine maintenance includes quarterly inspection of air filters, semi-annual testing of UPS battery strings, annual calibration of temperature and humidity sensors, and a yearly fire suppression system pressure check. The KITOZER controller logs all alarms and events with timestamps, enabling remote diagnostics before a site visit is required. For long-term operation, keep the external condenser area clear of debris and vegetation, and inspect the door gaskets annually to maintain the IP55 rating.
Price
From $28,500 per unit, including factory FAT test, standard accessories, and one year of on-site remote support. Contact the KITOZER engineering team for a customized quotation based on specific climate, power, and rack requirements.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com