KITOZER
KITOZER

KITOZER 20ft Container Data Center 40kW Liquid Cooled High Density

Product Overview

The KITOZER 20ft container data center with 40kW IT load is designed for high-density edge deployments where rack power exceeds 5kW per rack and traditional air cooling reaches its practical limit. The unit integrates rear-door heat exchangers and an integrated CDU (coolant distribution unit) to transfer rack-generated heat directly to liquid loops, leaving the internal air loop stable and comfortable for technicians. The container shell follows the same ISO 20ft form factor as the standard air-cooled model, allowing transport by standard container truck and placement in urban, industrial, or remote outdoor environments. Inside, the layout supports up to eight 42U racks with hot/cold aisle separation and a dedicated service corridor.

Technical Specifications

Rated IT load is 40kW continuous, with peak support up to 48kW for one hour. The cooling system uses a 60kW air-cooled condenser outside the container and an internal CDU delivering 30 percent propylene glycol mixture at 35 to 45 degrees Celsius supply temperature. Each rack can be fitted with a rear-door heat exchanger rated up to 8kW per door. Power distribution includes a 100A three-phase input, 40kVA online UPS with 20 minutes backup using valve-regulated lead-acid batteries, and rack-level PDU metering. The KITOZER master controller monitors rack inlet temperature, CDU supply and return temperature, pump status, and leak detection across the liquid loop. Operating ambient range is minus 20 to 50 degrees Celsius, and the container achieves IP55 with anti-corrosion coating for coastal sites.

Application Scenarios

This liquid-cooled 20ft container targets artificial intelligence inference nodes, video analytics farms, GPU rendering clusters, and telco central offices where space is limited but rack density is rising. It is also well suited for factory-floor edge data centers supporting digital twin simulation, real-time quality inspection, and machine vision processing. In pharmaceutical and food processing plants, the sealed container isolates sensitive IT equipment from dust, humidity, and wash-down environments. Research laboratories and university campuses use the unit as a compact, relocatable HPC cluster for computational fluid dynamics, finite element analysis, and genomics workloads.

Advantages and Features

The liquid cooling architecture reduces fan energy and delivers a target PUE below 1.25 in mild climates, significantly lower than air-cooled alternatives. Rear-door heat exchangers capture waste heat at the source, preventing hot spots even when individual racks run at 8kW. The CDU is installed inside the container with redundant pumps, so a single pump failure triggers an automatic switchover without interrupting cooling. All liquid connections use dry-break quick couplings, minimizing spill risk during rack maintenance. The KITOZER monitoring platform exports data via Modbus TCP, BACnet, and SNMP, integrating with building management systems and third-party DCIM tools. The unit also supports optional battery energy storage extension, solar input, and hydrogen fuel cell backup for off-grid operation.

Installation and Maintenance Recommendations

Site preparation includes a level concrete pad, three-phase power supply, network fiber termination, and a clear area for the external air-cooled condenser with at least one meter of clearance on all sides. During commissioning, the glycol mixture must be tested for concentration and pH, and all liquid couplings torque-checked before pressure testing the loop. Routine maintenance includes quarterly filter replacement on the CDU, semi-annual leak sensor testing, annual condenser coil cleaning, and a yearly UPS battery impedance test. The KITOZER controller provides predictive alarms for pump wear, filter clogging, and coolant degradation, allowing maintenance teams to plan interventions before failures occur. For cold climates, electric trace heating on external pipework is recommended to prevent freezing during winter shutdown.

Price

From $46,800 per unit, including CDU, rear-door heat exchangers, external condenser, UPS, and factory FAT. Contact KITOZER for a detailed proposal based on rack density and ambient climate.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart