KITOZER 20ft Container Data Center 60kW Outdoor Industrial

Product Overview

The KITOZER 20ft container data center rated at 60kW IT load is the highest-density configuration in the 20ft form factor, engineered for outdoor industrial environments where space is constrained but compute demand is heavy. It combines direct expansion precision cooling with rear-door heat exchanger assistance, a robust power chain with 100kVA UPS, and a hardened enclosure designed for dust, sand, and vibration. The unit is suitable for outdoor placement in steel mills, cement plants, paper mills, seaports, and railway stations, providing local compute and storage close to production equipment. The container shell uses reinforced corten steel with double-wall insulation and a fully sealed floor to prevent dust ingress.

Technical Specifications

Continuous IT load is 60kW across up to 10 racks, with per-rack support up to 8kW. Cooling consists of two 30kW precision air conditioners with N+1 redundancy, supplemented by optional rear-door liquid heat exchangers for high-density racks. Power chain includes a 160A three-phase mains inlet, 100kVA online double-conversion UPS with 30 minutes of battery autonomy, and individual rack PDUs with local and remote metering. The KITOZER master controller integrates 64 monitoring points covering temperature, humidity, smoke, water leakage, door status, vibration, and intrusion. Communication options include Modbus TCP, SNMP, BACnet, and 4G LTE for sites without wired network. Operating range is minus 30 to 55 degrees Celsius, IP55 enclosure, and anti-corrosion C5-M coating option for coastal and chemical plants.

Application Scenarios

This 60kW outdoor container targets industrial internet deployments that require local data processing near heavy machinery. Typical uses include steel mill process control and SCADA hosting, seaport container terminal management systems, railway signaling and traffic control backends, mining fleet management servers, and cement plant quality control systems. It also serves as a temporary disaster recovery node for banks, government agencies, and healthcare providers during main data center maintenance or emergency events. Solar-plus-storage versions are available for remote sites without grid power, enabling fully off-grid operation for weeks at a time.

Advantages and Features

The hardened industrial design allows operation in extreme ambient temperatures, with supplemental heating and thermal shading to prevent internal condensation. The dual cooling strategy balances efficiency and resilience: direct expansion air conditioning handles normal load, while rear-door liquid exchangers absorb peak heat from dense GPU or storage racks. The 100kVA UPS with extended battery cabinet supports graceful shutdown of IT loads and automatic generator takeover coordination. KITOZER remote monitoring enables predictive maintenance, with alarms routed to email, SMS, and cloud dashboards. The container is also designed for rapid relocation: all major components slide out on rails, and the whole unit can be lifted by crane or loaded onto a standard flatbed truck.

Installation and Maintenance Recommendations

Prepare a reinforced concrete pad capable of supporting the 8.5 ton unit plus wind load, and ensure drainage directs rainwater away from the container base. Provide a three-phase 160A feed and a grounded network drop. During installation, inspect door gaskets and cable entry glands before sealing, and verify that the internal equipotential bonding bar is connected to site ground. Maintenance tasks include monthly air filter inspection, quarterly UPS battery check, semi-annual precision cooling compressor performance test, and annual fire suppression actuator test. The KITOZER controller records component runtime hours, helping the maintenance team schedule filter changes and fan replacements based on actual usage rather than calendar cycles.

Reliability and Quality Assurance

The industrial-grade 60kW container is subjected to extended factory testing including vibration simulation, salt spray testing for the anti-corrosion coating, and 72 hours of full-load burn-in at elevated ambient temperature. The reinforced shell is load-tested for wind and seismic conditions, and all external cable entries are sealed and pressure-tested. Critical components including the 100kVA UPS, precision cooling units, and C5-M coating meet international standards for industrial and coastal environments. KITOZER provides a full documentation package with as-built drawings, test reports, and compliance certificates. The design service life is 20 years, with all heavy-duty components rated for continuous operation. A five-year warranty covers manufacturing defects, and extended service contracts include on-site spare parts storage and guaranteed response times. The remote support team monitors the controller 24/7, enabling proactive maintenance and rapid fault diagnosis.

Sustainability and Environmental Responsibility

The N+1 cooling design and hot aisle containment reduce overall energy consumption compared with traditional air-conditioned server rooms, lowering both operating cost and carbon emissions. The corten steel container is fully recyclable at end of life, and all electronic components meet RoHS compliance standards. KITOZER offers optional on-site battery storage and solar PV integration, allowing the unit to run on renewable energy during daylight hours. The industrial enclosure is designed for a 20-year service life, reducing the environmental impact of frequent equipment replacement. These features help customers meet corporate sustainability targets and qualify for green building certifications.

Price

From $62,000 per unit, including 100kVA UPS, N+1 precision cooling, industrial-grade enclosure, and factory acceptance test. Contact KITOZER engineering for project-specific configuration.