KITOZER 22U Server Cabinet 600x800mm Mid Duty Rack

Product Overview

The KITOZER 22U server cabinet is a mid-duty floor-standing enclosure that balances compact size with deeper internal volume, making it a popular choice for small and medium data centers, enterprise branch offices, campus network rooms, and monitoring centers. At 600 mm wide and 800 mm deep, it can accommodate 1U and 2U rack servers, storage arrays, blade chassis midplanes, and longer network switches that would not fit in a 600 mm deep cabinet. The frame is constructed from folded and welded cold-rolled steel with a static load rating of 800 kg, and dynamic load rating of 500 kg when the cabinet is moved on casters. The front perforated steel door, rear perforated door, and removable lockable side panels form a sealed yet ventilated enclosure that supports both front-to-back airflow and optional hot-aisle or cold-aisle containment in larger rooms. Adjustable 19-inch rails allow installers to position equipment at the ideal depth for cable management and rear service access. Every cabinet is factory tested for structural rigidity, door operation, and coating quality.

Technical Specifications

External dimensions are 600 mm wide, 800 mm deep, and approximately 1200 mm tall. Usable height is 22U. The cabinet provides adjustable 19-inch mounting rails with square-hole pattern, supporting equipment depth up to 750 mm. Static load capacity is 800 kg. Standard finish is RAL 7035 or RAL 9005 epoxy powder coating after phosphate treatment. Front and rear doors are perforated steel with more than 75 percent open area; the front door can also be supplied as tempered glass on request. Top cable entry includes two cable gland plates with brush strips. Roof fan tray supports up to four 120 mm fans with a thermostatic controller. Vertical PDU flanges are pre-punched on both sides. Included accessories are leveling feet, M6 cage nuts, screws, keys, and a grounding kit. Casters and a swivel caster kit are available as options. A bottom plinth or seismically anchored base can also be specified.

Applications

This cabinet is well suited for corporate server rooms, hospital IT closets, university network distribution points, government branch equipment rooms, factory SCADA server rooms, and retail chain headquarters. It can house a mix of 1U web servers, 2U storage nodes, 48 port gigabit switches, a 6 kVA online UPS, a tape autoloader, and a KVM console. The 800 mm depth is ideal for modern servers that include redundant power supplies at the rear, because the depth leaves room for cable loops and PDU mounting behind the equipment without compressing cords. It is also suitable for small unified communications deployments that combine PBX servers, switches, and UPS in a single cabinet.

Advantages and Features

KITOZER 22U cabinets are designed with reinforced base frames to prevent deflection under heavy server loads. The adjustable rails allow equipment depth adjustment without tools during installation. Perforated doors support high airflow rates, reducing fan energy consumption compared with solid glass doors. The cabinet is compatible with third-party cable management arms, sliding shelves, and rack PDUs, giving customers flexibility to evolve the installation. All doors and side panels lock with the same key system for site-level security. The steel is phosphated before powder coating, providing protection in air-conditioned environments with controlled humidity. The narrow 600 mm width allows more cabinets per row, improving floor space efficiency. Factory inspection includes dimensional checks, load tests, and door cycle testing to ensure long service life.

Installation and Maintenance Recommendations

Level the cabinet using the adjustable feet and anchor it to the floor if required by seismic codes. Place heavy devices such as UPS units and disk arrays at the bottom, and switches or patch panels in the middle U positions for easy access. Use cable management arms to support flexible power and data cords behind sliding equipment. Install blanking panels in unused U spaces to prevent hot air recirculation. Route power cables on one side of the cabinet and data cables on the other to reduce crosstalk. Inspect fans, filters, and PDU breakers every six months. Keep inlet air between 18 and 27 degrees Celsius per ASHRAE guidelines. The cabinet price starts from $380 per unit depending on door type, fan tray, and PDU configuration. Contact KITOZER for volume pricing, CAD drawings, and lead time.