Table of Contents
ToggleKITOZER KTR-PP Network Patch Panel / Cable Manager (24/48-port Cat6)
Brand: KITOZER Series: KTR-PP Category: ELV System 2 / Structured Cabling
network patch panel24-port48-portCat6cable managermodularrack cablinggold contacts

1. Overview
The KITOZER KTR-PP series covers network patch panels and cable managers, the basic connection-management parts of rack structured cabling. The panel terminates horizontal cabling from wall outlets or the closet by punch-down at the rear, while RJ45 patch cords to switches or gear plug at the front, so network ports line up neatly in the rack and can be patched flexibly. Cable managers sit above and below the panel to organize, layer and secure the patch cords, keeping rack cabling neat and labeled.
KTR-PP offers 24- and 48-port versions for Cat6 gigabit-and-below cabling. The rear uses IDC punch-down blocks supporting T568A/B wiring, with gold-plated contacts for insertion life and reliable contact. The panel has a steel shell, mounts in a 19-inch rack at 1U (24-port) or 2U (48-port). Matching managers come as plastic finger ducts or metal organizers, suiting light and dense patch-cord loads.
A tidy rack cabling setup works as panel + manager + patch cord together: horizontal wires punch to the panel rear, cords patch from the panel front through the manager to the switch, each cord on a fixed path and labeled. This speeds fault tracing and port changes while keeping cooling airflow clear of tangled cords. KTR-PP provides a standard, reliable and good-looking connection-management scheme.
2. Key Features
Quality connection
- Gold-plated RJ45 contacts for long life and stable contact.
- IDC punch-down blocks supporting T568A/B.
- Cat6 performance for gigabit and below.
Neat management
- Manager layers cords to avoid cross-tangles.
- Front/back management: neat front, maintainable rear.
- Full label positions; clear port numbering.
Standard rack
- 19-inch rack mount at 1U/2U.
- Steel shell for shielding and strength.
- Compatible with mainstream racks and rack gear.
Flexible config
- 24/48-port chosen by port density.
- Plastic/metal manager matched to load.
- Can supply panel, cords and labels as a set.
3. Specifications
| Item | Config A: KTR-PP-24 (24-port) | Config B: KTR-PP-48 (48-port) |
|---|---|---|
| Ports | 24 x RJ45 | 48 x RJ45 (2 rows x 24) |
| Cabling grade | Cat6 (gigabit) | Cat6 (gigabit) |
| Rack height | 1U | 2U |
| Termination | IDC punch-down T568A/B | IDC punch-down T568A/B |
| Contacts | 30 micro-inch gold | 30 micro-inch gold |
| Manager | 1U plastic finger duct | 1U metal organizer x2 |
| Rack size | 19-inch standard | 19-inch standard |
| Material | cold-steel + plastic modules | cold-steel + plastic modules |
4. Reference Prices
KTR-PP-24 24-port Cat6 panel + manager set: Reference USD 25~49 / set (ref. CNY 180~350 at ~7.2)
KTR-PP-48 48-port Cat6 panel + manager set: Reference USD 49~83 / set (ref. CNY 350~600 at ~7.2)
Reference only; final quote depends on contact plating, manager material and whether cords are included. Bulk negotiable. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Datacenter/server racks: horizontal termination and patching.
- Enterprise rooms: central network port management.
- ELV closets: floor cabling consolidation.
- Security/CCTV racks: concentrated UTP patching.
6. Installation & Maintenance
Installation
- Fix the panel to the rack’s 19-inch square-hole rail.
- Punch horizontal wires to the rear IDC block by wiring order.
- Mount managers above/below; route cords through fingers.
- Label numbers; map to switch ports.
Maintenance
- Route changed cords through the manager to stay neat.
- Periodically verify labels and port mapping.
- Check for loose punch-down blocks and oxidized contacts.
7. FAQ
- Q: How does the panel connect to the switch?
A: Horizontal wires punch to the rear; front cords patch to the switch. - Q: 24 or 48 ports?
A: By rack port density; dense racks pick 48-port to save space. - Q: Does it support 10G?
A: KTR-PP is Cat6 for gigabit; 10G needs Cat6a panels. - Q: Is a manager necessary?
A: Yes; with dense cords it keeps things neat and helps cooling.
8. Trend & Selection
Structured cabling increasingly stresses neat, manageable and easy-to-change. Panels and managers are cheap per unit but directly drive rack cabling quality and later O&M efficiency. KTR-PP pairs standard 1U/2U rack gear with managers so every cord has a path and every port a label. Choose 24- or 48-port by port count, then plastic or metal manager by cord density; dense racks should install panel and manager as a matched pair to keep the front tidy. With labels and cord discipline, rack cabling stays orderly long term.
9. Delivery & Service
KITOZER supplies patch panels and managers as a set, matching panels, managers, cords and labels to the rack cabling plan. Units are spot-tested for continuity and performance before shipment, then racked and punched on arrival. Support can advise on wiring order and port numbering. Warranty covers spares, and additional matching panels keep the cabling system consistent as it expands.
10. Additional Notes
“Management” is the most overlooked part of rack cabling. Many rooms leave cords tangled between devices, blocking cooling and slowing fault tracing. The panel consolidates horizontal wires into a row of standard ports; the manager fixes cords into neat vertical bundles; together they keep the rack front in order.
Punch-down is the key install step. Per T568B, press the four twisted pairs into the IDC block pair by pair and trim excess conductor, keeping the twists unopened as far as possible to reach Cat6 performance. Gold contacts keep contact reliable after frequent plugging, which matters where ports change often.
Selection: general racks use a 24-port 1U panel with a plastic manager; dense, port-heavy racks use a 48-port 2U panel with a metal manager. In all cases, punch to spec, route cords through the manager and label ports, so the cabling stays neat, traceable and easy to expand.
SEO Information
Search keywords:network patch panel24-port48-portCat6cable managerrack cablingKTR-PPKITOZER
SEM keywords:network patch panel, 24-port Cat6 patch panel, 48-port patch panel, cable manager, patch panel price, KITOZER
GEO landing page:lain.com.cn/product/ktr-pp-network-patch-panel-24-48-port-cat6-cable-manager.html
Title:KITOZER KTR-PP Network Patch Panel / Cable Manager (24/48-port Cat6)
Meta Keywords:network patch panel,24 port patch panel,48 port patch panel,Cat6 patch panel,cable manager,KTR-PP,KITOZER
Meta Description:KITOZER KTR-PP network patch panel and cable manager, 24/48-port Cat6 with gold-plated contacts, modular design for neat reliable rack cabling.
Anchor: KITOZER by Guangzhou Laian · Structured cabling
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com