KITOZER
KITOZER

KITOZER 24-Port ODF Fiber Distribution Frame LC Duplex

Product Overview

The KITOZER 24-port Optical Distribution Frame provides high-density fiber termination in a 1U rack-mount enclosure, supporting 24 fibers via LC duplex adapters. This ODF is the standard choice for building fiber backbones, data center top-of-rack patching, and campus inter-building fiber distribution. The chassis combines a front LC adapter panel, internal splice trays, and rear cable management into one robust unit. A removable top cover protects splice areas from dust while allowing quick access during installation.

The LC duplex panel packs 24 fiber connections into the same 1U space that an SC simplex panel would use for only 12 ports, making this ODF the preferred choice for dense server racks where every rack unit counts. The slide-out tray extends forward on smooth steel runners, giving installers access to the rear of the adapter panel without unracking the unit. Pre-loaded LC adapters use zirconia ceramic sleeves for precise ferrule alignment and low insertion loss.

Technical Specifications

Housing: 1U 19-inch, cold-rolled steel 1.2mm, black powder coat. Adapter interface: 24 x LC duplex adapters (equivalent to 48 fiber ends), ceramic zirconia sleeve. Splice capacity: 24 cores across two slide-out splice trays. Fiber type: OS2 singlemode standard; OM3/OM4 multimode optional. Insertion loss: less than 0.2dB for LC UPC, return loss greater than 50dB. Cable entry: rear gland plate supports 2 to 4 round cables up to 18mm. Operating temperature: -10C to +60C. Dimensions: 482mm x 300mm x 44mm. Includes: 24 LC UPC pigtails 1.5m, two splice trays, splice protectors, grounding kit. KITOZER brand, 3 year warranty.

The splice trays are hinged and stackable, allowing technicians to open one tray without disturbing fibers routed through the tray above. Each tray holds 12 splices in individual grooves and includes a built-in radius guide that maintains the 30mm minimum bend radius between the cable entry and the splice point. The rear gland plate accepts up to four round cables of 10mm to 18mm diameter, supporting multiple backbone entries in a single ODF.

Applications

Typical deployments include data center TOR switch fiber termination, enterprise core router uplinks, and FTTH ODF distribution in telecom operator stations. The LC duplex density also supports high-density 10G/25G/40G server connections where each port requires two fibers. It is also used in financial trading rooms, hospital campus networks, and university research fiber backbones.

In data centers, the ODF sits in the main distribution area (MDA) and connects via trunk cables to horizontal distribution areas (HDAs) in each row. In enterprise buildings, it terminates the riser fiber that runs between floors, with patch cords dropping down to floor switches. The unit is also suitable as a cross-connect point between carrier fiber and customer equipment in co-location facilities.

Key Advantages

The LC adapter panel delivers twice the port density of SC panels in the same 1U space, valuable in densely packed racks. Slide-out trays allow splicing and patching without disconnecting active links. All internal fiber routing channels maintain a 30mm bend radius, preventing signal loss in bend-insensitive fiber. Adapter dust caps are tethered to the panel so they cannot be lost. The unit ships pre-assembled and factory tested for insertion loss, reducing on-site commissioning time by up to 50 percent.

The modular adapter frame is field-replaceable, allowing a future upgrade from OS2 to OM4 multimode by swapping the adapter plate and pigtails without replacing the enclosure. The powder-coated steel resists scratches and corrosion in typical indoor environments. Port numbers are laser-etched rather than printed, so they remain legible for the life of the product.

Installation and Maintenance

Secure the ODF to the rack using front and rear brackets. Feed backbone cables through the rear gland plate, strip jackets, and land strength members to the built-in anchor bar. Open a splice tray, fusion splice each incoming fiber to a factory LC pigtail, and seat the splice protector in the tray groove. Route pigtails to the rear of the LC adapters using the integrated radius guide. Close the tray and test each port with an OTDR or light source and power meter. Label both ports and patch cords.

Clean adapter end faces before every mating. Re-tighten cable glands every six months. Keep spare dust caps on hand. During preventive maintenance, verify that slide rails move smoothly and that the top cover seals properly. If a port develops high loss, first clean the ferrule and adapter sleeve; if loss persists, inspect the splice with an OTDR to locate a microbend or a defective splice.

Packaging and Compliance

Each ODF is packed in a corrugated carton with foam protection. The carton includes a factory test report, installation manual, spare splice protectors, and a grounding wire. RoHS and CE compliant. Custom lengths, APC polish, and MPO adapter options are available for volume orders.

Price

From $145/pc. Contact +86 13922289957 for factory price and lead time.