The KITOZER 24-string 1500V DC combiner box is built for utility-scale ground-mount photovoltaic plants where long cable runs and large string counts demand higher voltage and heavier short-circuit protection. Each enclosure consolidates up to twenty-four array strings into two 1500V DC output feeds, feeding a central inverter or a 1500V string inverter station. The cabinet is designed for outdoor 24/7 operation across desert, temperate, and tropical climates, with an internal layout that leaves room for cable bending radius and service access without removing major components.
Table of Contents
ToggleProduct Overview
Inside the KITOZER 24-string combiner, every string lands on a labeled terminal block and passes through a gPV fuse rated 20A at 1500V. A Type II DC surge protector module with 50kA discharge capacity clamps transient surges induced by nearby lightning. A molded-case DC circuit breaker serves as the main disconnection and short-circuit protective device on the output bus. The optional string monitoring unit uses isolated hall sensors on each channel and reports to the plant SCADA via fiber-optic Ethernet, eliminating ground-loop issues common in large plants. The door carries a padlockable handle, a visible auxiliary contact for remote door status, and a stainless steel nameplate engraved with the factory serial number and wiring diagram.
Technical Specifications
Maximum system voltage 1500V DC, 24 string inputs at 20A per channel. String fuses gPV, 20A, 1500V, IEC 60269-6. Main DC breaker 400A, 1500V DC, with electronic shunt trip option. SPD Type II, 1500V DC, 50kA In, 100kA Imax, fail-safe dry contact. String monitor range 0 to 30A, accuracy 0.5 percent, isolated RS485 or fiber Ethernet. Enclosure IP66, C5-M coastal corrosion option, stainless steel 304 or 316L. Operating temperature minus 40 to plus 70 degrees Celsius. Approvals: IEC 61439, IEC 62619, GB/T 18216, CE. Five-year warranty from KITOZER.
Application Scenarios
The 24-string 1500V combiner is used in 5MW to 200MW utility plants built around 1500V central inverters and bifacial trackers. It is also specified for solar-plus-storage plants where the DC side must be segregated from the battery PCS feed, and for large distributed generation farms connected at medium voltage. Engineering teams choose this cabinet when the site is remote and requires local diagnostics, because the string monitor alarms can flag a failed tracker drive or a shaded module before the inverter trip log is consulted.
Key Advantages
Higher 1500V system voltage reduces line losses and allows longer string home runs, lowering the amount of copper cable in the field. The 24-channel density halves the number of combiners required compared with 12-channel boxes, cutting foundation and cabling labor. Isolated string monitoring avoids the noisy shared-bus measurement errors that plague low-cost combiners, and the fiber option safely bridges the potential differences between array sections. The C5-M stainless option survives coastal locations where standard powder-coated steel rusts within three years.
Installation and Maintenance
Set the combiner on a galvanized steel standoff at 50 centimeters above grade, and verify that the door opens a full 120 degrees without contacting the tracker pile. Pull strings from the racking in logical groups so labels match the cabinet schedule. Commission with an insulation resistance test at 1500V before the main breaker is closed. Every six months, check the SPD window, torque the main lugs, and pull a string current trend report from the SCADA to identify any channel drifting below 95 percent of the array average. Keep spare fuses of the exact rating on site, and never substitute AC fuses for gPV types.
Quality, Warranty and Delivery
KITOZER pressure-tests every 24-string combiner cabinet at the factory, verifying that each gPV fuse circuit carries the rated current without abnormal heating, that the main DC breaker opens cleanly on a simulated short circuit, and that the string monitor reports within 0.5 percent of a reference shunt. The cabinet is then wrapped in a corrosion-inhibiting film and loaded into a wooden crate with foam corner protectors for ocean freight. Each shipment is accompanied by a factory test report, a signed wiring schedule, a set of spare fuses, and a contact card for the KITOZER service desk. For multi-megawatt plants, KITOZER offers pre-shipment inspection by the owner or a third-party inspector such as SGS, BV, or TUV. The five-year warranty covers the cabinet, the breakers, and the string monitor, and spare parts are stocked at regional warehouses for fast dispatch. KITOZER also provides a commissioning video call with the first unit of each project, so the local crew can confirm polarity, insulation resistance, and Modbus addressing before the array is energized.
Price
From $3,280 per unit with basic protection, and from $5,980 per unit with string monitoring and fiber communication. Contact KITOZER for volume pricing on multi-megawatt projects.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com